Size quantification of liver metastases in patients undergoing cancer treatment: Reproducibility of one-, two-, and three-dimensional measurements determined with spiral CT

被引:71
作者
VanHoe, L
VanCutsem, E
Vergote, I
Baert, AL
Bellon, E
Dupont, P
Marchal, G
机构
[1] KATHOLIEKE UNIV LEUVEN HOSP,DEPT INTERNAL MED,B-3000 LOUVAIN,BELGIUM
[2] KATHOLIEKE UNIV LEUVEN HOSP,DEPT GYNECOL ONCOL,B-3000 LOUVAIN,BELGIUM
[3] BELGIAN NATL FUND SCI RES,BRUSSELS,BELGIUM
关键词
computed tomography (CT); helical; three-dimensional; liver; CT; liver neoplasms; secondary;
D O I
10.1148/radiology.202.3.9051014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the reproducibility of one-, two-, and three-dimensional measurements of the size of liver metastases. MATERIALS AND METHODS: The sizes of 10 liver metastases were determined 200 times: Ten observers measured each lesion by using images obtained at two different CT studies and with five different measurement techniques (maximum diameter, product of diameters, area, volume, and product of three diameters). They repeated each measurement in a separate session. The influence of measurement technique and lesion type (size and morphologic appearance) on measurement reproducibility was assessed. RESULTS: Three-dimensional measurements proved to be as reproducible as one- and two-dimensional measurements. Measurement reproducibility was influenced mainly by the size (P < .0001) and morphologic appearance (P < .01) of the lesions. CONCLUSION: Three-dimensional size measurements obtained with spiral CT are reproducible and could therefore replace the two-dimensional measurements of tumor size currently obtained with follow-up CT studies.
引用
收藏
页码:671 / 675
页数:5
相关论文
共 25 条
[1]  
ARIMOTO T, 1993, CANCER, V72, P2383, DOI 10.1002/1097-0142(19931015)72:8<2383::AID-CNCR2820720815>3.0.CO
[2]  
2-B
[3]   ESTIMATION OF TISSUE VOLUME FROM SERIAL TOMOGRAPHIC SECTIONS - A STATISTICAL RANDOM MARKING METHOD [J].
BENTLEY, MD ;
KARWOSKI, RA .
INVESTIGATIVE RADIOLOGY, 1988, 23 (10) :742-747
[4]   VOLUME DETERMINATIONS USING COMPUTED-TOMOGRAPHY [J].
BREIMAN, RS ;
BECK, JW ;
KOROBKIN, M ;
GLENNY, R ;
AKWARI, OE ;
HEASTON, DK ;
MOORE, AV ;
RAM, PC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (02) :329-333
[5]   MEASURING MASSES ON CROSS-SECTIONAL IMAGES [J].
FORNAGE, BD .
RADIOLOGY, 1993, 187 (01) :289-289
[6]   HOW ACCURATE ARE COMPUTED TOMOGRAPHIC SCANS IN ASSESSMENT OF CHANGES IN TUMOR SIZE [J].
FRIEDMAN, MA ;
RESSER, KJ ;
MARCUS, FS ;
MOSS, AA ;
CANN, CE .
AMERICAN JOURNAL OF MEDICINE, 1983, 75 (02) :193-198
[7]  
HAYWARD JL, 1977, CANCER, V39, P1289, DOI 10.1002/1097-0142(197703)39:3<1289::AID-CNCR2820390340>3.0.CO
[8]  
2-F
[9]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183
[10]  
LAVIN PT, 1980, CANCER, V46, P1286, DOI 10.1002/1097-0142(19800901)46:5<1286::AID-CNCR2820460533>3.0.CO