MULTIVARIATE IMAGE ANALYSIS IN CHEMISTRY: pH MEASUREMENTS OF DRINKING WATER

被引:27
作者
Damasceno, Deangelis [1 ]
Toledo, Thiago G. [2 ]
Godinho, Mariana S. [2 ]
da Silva, Cassiano P. [3 ]
de Oliveira, Sergio B. [4 ]
de Oliveira, Anselmo E. [2 ]
机构
[1] Inst Fed Educ Ciencia & Tecnol, BR-76600000 Cidade De Goias, Go, Brazil
[2] Univ Fed Goias, Inst Quim, BR-74001970 Goiania, Go, Brazil
[3] AQUALIT, BR-74603030 Goiania, Go, Brazil
[4] Inst Fed Educ Ciencia & Tecnol, BR-74055110 Goiania, Go, Brazil
来源
QUIMICA NOVA | 2015年 / 38卷 / 06期
关键词
MIA; PLS; drinking water; digital image processing; pH;
D O I
10.5935/0100-4042.20150082
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A Multivariate Image Analysis (MIA) laboratory activity was proposed estimating pH of drinking water samples from its digital images after adding bromothymol blue as a pH indicator, and using the PLS multivariate calibration method. All computational work was done using GNU Octave free software. The MIA-PLS based approach exemplified with drinking water pH estimates is tailored to meet the needs of both students and researchers. MIA-PLS method was statically equivalent to the reference method using a conventional glass pH electrode. This lab activity combines analytical methodology, computing, and chemometrics.
引用
收藏
页码:836 / 841
页数:6
相关论文
共 25 条
[1]  
[Anonymous], 1975, Perspectives in probability and statistics
[2]  
[Anonymous], 1992, R. woods digital image processing
[3]  
APHA, 1992, STANDARD METHODS EXA
[4]  
Atkins P., 2006, PRINCIPIOS QUIMICA
[5]   Digital image analysis and EDX SEM as combined techniques to evaluate salt damp on walls [J].
Auxiliadora Vazquez, Maria ;
Galan, Emilio ;
Ortiz, Pilar ;
Ortiz, Rocio .
CONSTRUCTION AND BUILDING MATERIALS, 2013, 45 :95-105
[6]   Capillary-Driven Toner-Based Microfluidic Devices for Clinical Diagnostics with Colorimetric Detection [J].
de Souza, Fabricio Ribeiro ;
Alves, Guilherme Liberato ;
Tomazelli Coltro, Wendell Karlos .
ANALYTICAL CHEMISTRY, 2012, 84 (21) :9002-9007
[7]   Speckle-Based Modulation Transfer Function Measurements for Comparative Evaluation of CCD and CMOS Detector Arrays [J].
Fernandez-Oliveras, Alicia ;
Pozo, Antonio M. ;
Rubino, Manuel .
OPTICAL REVIEW, 2013, 20 (01) :41-49
[8]   PARTIAL LEAST-SQUARES REGRESSION - A TUTORIAL [J].
GELADI, P ;
KOWALSKI, BR .
ANALYTICA CHIMICA ACTA, 1986, 185 :1-17
[9]   IMAGE-ANALYSIS AND CHEMICAL INFORMATION IN IMAGES [J].
GELADI, P ;
WOLD, S ;
ESBENSEN, K .
ANALYTICA CHIMICA ACTA, 1986, 191 :473-480
[10]   Carbonated soft drink classification based on image analysis and PCA [J].
Godinho, Mariana da S. ;
Pereira, Raquel O. ;
Ribeiro, Keysi de O. ;
Schimidt, Fernando ;
de Oliveira, Anselmo E. ;
de Oliveira, Sergio B. .
QUIMICA NOVA, 2008, 31 (06) :1485-1489