Full-Scale Validation of Dynamic Wind Load on a Super-Tall Building under Strong Wind

被引:19
作者
Au, Siu-Kui [1 ]
To, Ping [2 ]
机构
[1] City Univ Hong Kong, Dept Civil & Architectural Engn, Kowloon, Hong Kong, Peoples R China
[2] Ove Arup & Partners Hong Kong Ltd, Kowloon, Hong Kong, Peoples R China
关键词
Bayesian; Measurement; Modal identification; Structural health monitoring; Wind tunnel test; AMBIENT MODAL IDENTIFICATION; SYSTEM-IDENTIFICATION; FREQUENCY-DOMAIN; INDUCED RESPONSE; POSTERIOR;
D O I
10.1061/(ASCE)ST.1943-541X.0000539
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents work on validating the dynamic wind load predicted by a wind tunnel model with the values identified from full-scale field vibration data of a super-tall building in Hong Kong. Dynamic wind load in this work refers to the power spectral density (PSD) of the modal force near the natural frequency of a particular mode of the building, in the context of random vibration with stationary loading and response. This quantity reflects the turbulence characteristics integrated over the building body and is of importance in wind engineering design. This study presents a method to predict the modal PSD of wind load of the first two translational modes of a tall building. The method combines wind tunnel test information and mean wind data available in the free field; the latter taken to be at the Waglan Island station maintained by the Hong Kong Observatory. On the full-scale side, although the modal PSD is not directly observable, it is identified from field vibration data measured at the building top during strong wind events. A Bayesian modal identification method is used for determining the most probable value and the uncertainty of the modal parameters including the natural frequency, damping ratio, and the modal PSD. A number of recent strong wind events are analyzed. Reasonable agreement is observed between the wind tunnel model predictions and the values identified from field data. Factors that can potentially lead to discrepancy are discussed. As the same random vibration modeling consistent with conventional wind engineering design has been used in the wind tunnel prediction model and field identification model, the results are directly transferable among these three disciplines. DOI: 10.1061/(ASCE)ST.1943-541X.0000539. (C) 2012 American Society of Civil Engineers.
引用
收藏
页码:1161 / 1172
页数:12
相关论文
共 26 条
[1]  
[Anonymous], 2004, COD PRACT WIND EFF H
[2]  
[Anonymous], TIM SER WEATH INF
[3]   Full-scale dynamic testing and modal identification of a coupled floor slab system [J].
Au, S. K. ;
Ni, Y. C. ;
Zhang, F. L. ;
Lam, H. F. .
ENGINEERING STRUCTURES, 2012, 37 :167-178
[4]   Ambient modal identification of a primary-secondary structure by Fast Bayesian FFT method [J].
Au, Siu-Kui ;
Zhang, Feng-Liang .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2012, 28 :280-296
[5]   Field observations on modal properties of two tall buildings under strong wind [J].
Au, Siu-Kui ;
Zhang, Feng-Liang ;
To, Ping .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2012, 101 :12-23
[6]   Fast Bayesian ambient modal identification in the frequency domain, Part I: Posterior most probable value [J].
Au, Siu-Kui .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2012, 26 :60-75
[7]   Fast Bayesian ambient modal identification in the frequency domain, Part II: Posterior uncertainty [J].
Au, Siu-Kui .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2012, 26 :76-90
[8]   Fast Bayesian FFT Method for Ambient Modal Identification with Separated Modes [J].
Au, Siu-Kui .
JOURNAL OF ENGINEERING MECHANICS, 2011, 137 (03) :214-226
[9]   Bayesian system identification based on probability logic [J].
Beck, James L. .
STRUCTURAL CONTROL & HEALTH MONITORING, 2010, 17 (07) :825-847
[10]   AERODYNAMIC MODEL TESTS OF TALL BUILDINGS [J].
BOGGS, DW ;
PETERKA, JA .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 1989, 115 (03) :618-635