NUMERICAL ANALYSIS OF AN AXIAL BLOOD PUMP WITH DIFFERENT IMPELLER BLADE HEIGHTS

被引:7
作者
Qi, Jiaxing [1 ]
Zhou, Yanhong [1 ]
Wang, Dongfang [2 ]
Zhong, Liang [3 ]
机构
[1] Huazhong Univ Sci & Technol, Dept Biomed Engn, Wuhan 430074, Hubei, Peoples R China
[2] Univ Kentucky, Coll Med, Lexington, KY 40506 USA
[3] Natl Heart Ctr Singapore, Dept Cardiol, Singapore 168752, Singapore
关键词
Computational fluid dynamics; axial blood pump; left ventricular assist device (LVAD); inner flow; COMPUTATIONAL FLUID-DYNAMICS; LEFT-VENTRICULAR ASSIST; PARTICLE IMAGE VELOCIMETRY; FLOW VISUALIZATION; CENTRIFUGAL PUMP; DESIGN; DEVICE; HEMOCOMPATIBILITY; DIFFUSER; HEART;
D O I
10.1142/S0219519411004629
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Computational fluid dynamics (CFD) simulations of the flow in an axial blood pump with different blade heights (BH150, BH200 and BH250) were performed in the present study. The flow in the pump was assumed as steady and turbulent, and blood was treated as incompressible and Newtonian fluid. The flow rate increased with the rise in blade heights. At the impeller rotating speed of 20,000 rpm and a pressure of 100 mm Hg, the pump produces a flow rate up to 5 L/min in BH200 and BH250 models. The reverse flow and vortices have been identified in the BH150 and BH200 models in the outlet regions, but not for BH250 model. The high shear stress of the flow in the pump mainly occurred at the blade tips. The BH200 model achieved an expected flow rate up to 5 L/min with 90% of the shear stresses less than 500 Pa and the exposure time less than 22 ms, which has the acceptable shear stress level in the literature.
引用
收藏
页数:13
相关论文
共 35 条
  • [1] RECENT STUDIES OF THE CENTRIFUGAL BLOOD PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER
    AKAMATSU, T
    TSUKIYA, T
    NISHIMURA, K
    PARK, CH
    NAKAZEKI, T
    [J]. ARTIFICIAL ORGANS, 1995, 19 (07) : 631 - 634
  • [2] Numerical analysis of blood flow in the clearance regions of a continuous flow artificial heart pump
    Anderson, J
    Wood, HG
    Allaire, PE
    Olsen, DB
    [J]. ARTIFICIAL ORGANS, 2000, 24 (06) : 492 - 500
  • [3] Comparison of hydraulic and hemolytic properties of different impeller designs of an implantable rotary blood pump by computational fluid dynamics
    Arvand, A
    Hahn, N
    Hormes, M
    Akdis, M
    Martin, M
    Reul, H
    [J]. ARTIFICIAL ORGANS, 2004, 28 (10) : 892 - 898
  • [4] A review of computational fluid dynamics analysis of blood pumps
    Behbahani, M.
    Behr, M.
    Hormes, M.
    Steinseifer, U.
    Arora, D.
    Coronado, O.
    Pasquali, M.
    [J]. EUROPEAN JOURNAL OF APPLIED MATHEMATICS, 2009, 20 : 363 - 397
  • [5] 3-DIMENSIONAL NUMERICAL PREDICTION OF STRESS LOADING OF BLOOD PARTICLES IN A CENTRIFUGAL PUMP
    BLUDSZUWEIT, C
    [J]. ARTIFICIAL ORGANS, 1995, 19 (07) : 590 - 596
  • [6] Determination of the in vivo cavitation nuclei characteristics of blood
    Chambers, SD
    Bartlett, RH
    Ceccio, SL
    [J]. ASAIO JOURNAL, 1999, 45 (06) : 541 - 549
  • [7] Numerical and in vitro investigations of pressure rise in a new hydrodynamic blood bearing
    Chan, Weng-Kong
    Ooi, Kim-Tiow
    Loh, Yan-Chuan
    [J]. ARTIFICIAL ORGANS, 2007, 31 (06) : 434 - 440
  • [8] Computational fluid dynamics Modeling of impeller designs for the HeartQuest left ventricular assist device
    Curtas, AR
    Wood, HG
    Allaire, PE
    McDaniel, JC
    Day, SW
    Olsen, DB
    [J]. ASAIO JOURNAL, 2002, 48 (05) : 552 - 561
  • [9] Research and development of an implantable, axial-flow left ventricular assist device: The Jarvik 2000 heart
    Frazier, OH
    Myers, TJ
    Jarvik, RK
    Westaby, S
    Pigott, DW
    Gregoric, ID
    Khan, T
    Tamez, DW
    Conger, JL
    Macris, MP
    [J]. ANNALS OF THORACIC SURGERY, 2001, 71 (03) : S125 - S132
  • [10] Hirsch Douglas J, 2003, Anesthesiol Clin North Am, V21, P625, DOI 10.1016/S0889-8537(03)00049-X