High-resolution local imaging using a micro-CT

被引:0
作者
Lee, Soo Yeol [1 ]
Cho, Min Hyoung [1 ]
Choi, Jeong Min [1 ]
机构
[1] Kyung Hee Univ, Dept Biomed Engn, Seoul, South Korea
来源
2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4 | 2008年
关键词
micro-CT; zoom-in imaging; small animal imaging; rotating gantry; flat panel x-ray detector;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An x-ray micro-tomography system has been developed for in vivo small animal imaging studies. For efficient in vivo scanning, it has a rotating gantry on which the x-ray source and the flat panel x-ray detector are mounted. To reconstruct artifact-free images of a small local region inside the animal subject from the truncated projection data, the projection data from the large field of view (FOV) scan of the whole animal subject are combined with the projection data from the small FOV scan of the region of interest. For the acquisition of x-ray projection data, a 1248 x 1248 flat-panel x-ray detector with the pixel pitch of 100 mu m has been used. The developed system has the spatial resolution of 12 lp/mm when the highest magnification ratio of 5:1 is applied to the zoom-in imaging.
引用
收藏
页码:137 / 140
页数:4
相关论文
共 11 条
[1]  
CHO MH, 2008, J BIOMED EN IN PRESS
[2]   X-ray micro-tomography system for small-animal imaging with zoom-in imaging capability [J].
Chun, IK ;
Cho, MH ;
Lee, SC ;
Cho, MH ;
Lee, SY .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (17) :3889-3902
[3]   In vivo trabecular thickness measurement in cancellous bones:: longitudinal rat imaging studies [J].
Chun, In Kon ;
Cho, Min Hyoung ;
Park, Ji-Ho ;
Lee, Soo Yeol .
PHYSIOLOGICAL MEASUREMENT, 2006, 27 (08) :695-702
[4]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[5]   Cone-beam computed tomography with a flat-panel imager: Initial performance characterization [J].
Jaffray, DA ;
Siewerdsen, JH .
MEDICAL PHYSICS, 2000, 27 (06) :1311-1323
[6]  
Kapadia R D, 1998, Technol Health Care, V6, P361
[7]   A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging [J].
Lee, SC ;
Kim, HK ;
Chun, IK ;
Cho, MH ;
Lee, SY ;
Cho, MH .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (24) :4173-4185
[8]   A new X-ray computed tomography system for laboratory mouse imaging [J].
Paulus, MJ ;
Sari-Sarraf, H ;
Gleason, SS ;
Bobrek, M ;
Hicks, JS ;
Johnson, DK ;
Behel, JK ;
Thompson, LH ;
Allen, WC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :558-564
[9]   Molecular imaging in small animals - Roles for micro-CT [J].
Ritman, EL .
JOURNAL OF CELLULAR BIOCHEMISTRY, 2002, :116-124
[10]   Extraction of the hepatic vasculature in rats using 3-D micro-CT images [J].
Wan, SY ;
Kiraly, AP ;
Ritman, EL ;
Higgins, WE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) :964-971