Monitoring fouling behavior of reverse osmosis membranes using electrical impedance spectroscopy: A field trial study

被引:41
作者
Ho, Jia Shin [1 ,2 ]
Sim, Lee Nuang [1 ]
Webster, Richard D. [2 ]
Viswanath, Balakrishnan [3 ]
Coster, Hans G. L. [4 ]
Fane, Anthony G. [1 ,5 ]
机构
[1] Nanyang Technol Univ, Singapore Membrane Technol Ctr, Nanyang Environm & Water Res Inst, Singapore, Singapore
[2] Nanyang Technol Univ, Sch Phys & Math Sci, Div Chem & Biol Chem, Singapore, Singapore
[3] Publ Util Board, Singapore, Singapore
[4] Univ Sydney, Sch Chem & Biomol Engn, Sydney, NSW, Australia
[5] Nanyang Technol Univ, Sch Civil & Environm Engn, Singapore, Singapore
基金
新加坡国家研究基金会;
关键词
Electrical impedance spectroscopy fouling monitor; Fouling; Real time monitoring; Reverse osmosis; Canary cell; Field trial; TIME-DOMAIN REFLECTOMETRY; TRACER RESPONSE TECHNIQUE; SPIRAL-WOUND MEMBRANES; RO MEMBRANES; WASTE-WATER; NANOFILTRATION MEMBRANES; CALCIUM-PHOSPHATE; MASS-TRANSFER; CRITICAL FLUX; PRESSURE;
D O I
10.1016/j.desal.2016.12.012
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
An electrical impedance spectroscopy fouling monitor (EISFM) was used to monitor the performance of a reverse osmosis (RO) treatment train in a NEWater plant in Singapore. A 'canary cell' equipped with an EIS measurement system was installed in a side stream of the train. It was operated at the same hydrodynamics as the train to simulate the fouling conditions in the spiral wound modules. The correlation between the EISFM response and plant performance was investigated. When trending the real part of the impedance Of the low frequency signal element (Z(real_DP)) over time, there was a maximum in the normalised Z(real-DP) observed well before chemical cleaning which was indicated by the traditional operational criteria. The occurrence of Z(real-DP) peaks can be used as an indicator to initiate mitigation measures, such as adjustment of flux or crossflow velocity. As such, the frequency of chemical CIPs could be reduced. Furthermore, by obsenting the trend of Z(real-DP) over time, it was possible to identify the nature of the fouling such as the build-up of a layer of inorganic colloids. This was validated by membrane autopsy studies. This study confirms that the EISFM is suitable for monitoring the performance of RO in a real plant. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:75 / 84
页数:10
相关论文
共 47 条
[1]   Non-invasive measurement of membrane scaling and cleaning in spiral-wound reverse osmosis modules by ultrasonic time-domain reflectometry with sound intensity calculation [J].
An, Genghong ;
Lin, Jiebin ;
Li, Jianxin ;
Li, Xianhui ;
Jian, Xiqi .
DESALINATION, 2011, 283 :3-9
[2]   In situ structural and functional characterization of reverse osmosis membranes using electrical impedance spectroscopy [J].
Antony, Alice ;
Chilcott, Terry ;
Coster, Hans ;
Leslie, Greg .
JOURNAL OF MEMBRANE SCIENCE, 2013, 425 :89-97
[3]   Scale formation and control in high pressure membrane water treatment systems: A review [J].
Antony, Alice ;
Low, Jor How ;
Gray, Stephen ;
Childress, Amy E. ;
Le-Clech, Pierre ;
Leslie, Greg .
JOURNAL OF MEMBRANE SCIENCE, 2011, 383 (1-2) :1-16
[4]   Critical and sustainable fluxes: Theory, experiments and applications [J].
Bacchin, P. ;
Aimar, P. ;
Field, R. W. .
JOURNAL OF MEMBRANE SCIENCE, 2006, 281 (1-2) :42-69
[5]   Design considerations for wastewater treatment by reverse osmosis [J].
Bartels, CR ;
Wilf, M ;
Andes, K ;
Iong, J .
WATER SCIENCE AND TECHNOLOGY, 2005, 51 (6-7) :473-482
[6]   Real time fouling monitoring with Electrical Impedance Spectroscopy [J].
Cen, J. ;
Vukas, M. ;
Barton, G. ;
Kavanagh, J. ;
Coster, H. G. L. .
JOURNAL OF MEMBRANE SCIENCE, 2015, 484 :133-139
[7]   Implications of critical flux and cake enhanced osmotic pressure (CEOP) on colloidal fouling in reverse osmosis: Experimental observations [J].
Chong, T. H. ;
Wong, F. S. ;
Fane, A. G. .
JOURNAL OF MEMBRANE SCIENCE, 2008, 314 (1-2) :101-111
[8]   Fouling in reverse osmosis: Detection by non-invasive techniques [J].
Chong, T. H. ;
Wong, F. S. ;
Fane, A. G. .
DESALINATION, 2007, 204 (1-3) :148-154
[9]   Enhanced concentration polarization by unstirred fouling layers in reverse osmosis: Detection by sodium chloride tracer response technique [J].
Chong, T. H. ;
Wong, F. S. ;
Fane, A. G. .
JOURNAL OF MEMBRANE SCIENCE, 2007, 287 (02) :198-210
[10]   Air sparging for flux enhancement in nanofiltration membranes: application to O/W stabilised and non-stabilised emulsions [J].
Ducom, G ;
Matamoros, H ;
Cabassud, C .
JOURNAL OF MEMBRANE SCIENCE, 2002, 204 (1-2) :221-236