The Effect of Filtration on Residual Levels of Coagulation Factors in Plasma

被引:9
作者
Alhumaidan, Hiba S. [1 ]
Cheves, Tracey A. [1 ]
Holme, Stein [2 ]
Sweeney, Joseph D. [1 ]
机构
[1] Miriam Hosp, Blood Bank & Transfus Med Res Unit, Providence, RI 02906 USA
[2] Pall Med, Covina, CA USA
关键词
Blood filtration; Clotting factors; FRESH-FROZEN PLASMA; PRESTORAGE LEUKOCYTE DEPLETION; IN-LINE FILTRATION; WHOLE-BLOOD; UNIVERSAL LEUKOREDUCTION; TEMPERATURE; QUALITY; STORAGE; COMPONENTS; FILTERS;
D O I
10.1309/AJCPRRESG7PGIAH5
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Leukoreduced blood components are commonly manufactured via filtration. There are specifications for the residual leukocyte content of any final cellular blood component but not for residual clotting factors. Leukoreduced and nonleukoreduced platelet-poor plasma products were manufactured from filtered vs unfiltered platelet-rich plasma, respectively, using platelet leukoreduction filters. The leukoreduced plasma showed lower levels of factor VIII (75% +/- 16% vs 88% +/- 18%, P <= .05), factor XI (86% +/- 9% vs 96% +/- 10%, P <= .01) and factor VII (87% +/- 14% vs 98% +/- 11%, P <= .01). No difference was seen with factor X factor V, or fibrinogen. Plasma filtered through a whole blood filter showed a reduction in factor V (105% +/- 12% vs 124% +/- 10%, P <= .01) but a minimal reduction in factor VIII (80% +/- 5% vs 82% +/- 6%, P = .04). Filtration can alter the residual levels of clotting factors to a variable extent in manufactured plasma, most noticeably factors V, VII, VIII, and XI.
引用
收藏
页码:110 / 116
页数:7
相关论文
共 23 条
[1]  
Alhumaidan H, 2010, TRANSFUSION, V50, p8A
[2]   Stability of coagulation factors in plasma prepared after a 24-hour room temperature hold [J].
Alhumaidan, Hiba ;
Cheves, Tracey ;
Holme, Stein ;
Sweeney, Joseph .
TRANSFUSION, 2010, 50 (09) :1934-1942
[3]  
American Association of Blood Banks, 2011, STAND BLOOD BANK TRA
[4]  
[Anonymous], 2011, AABB TECHNICAL MANUA
[5]   The effect of leucocyte depletion on the quality of fresh-frozen plasma [J].
Cardigan, R ;
Sutherland, J ;
Garwood, M ;
Krailadsiri, P ;
Seghatchian, J ;
Beard, M ;
Beckman, N ;
Williamson, LM .
BRITISH JOURNAL OF HAEMATOLOGY, 2001, 114 (01) :233-240
[6]   Quality assessment of seven types of fresh-frozen plasma leucoreduced by specific plasma filtration [J].
Chabanel, A ;
Sensebé, I ;
Masse, M ;
Maurel, JP ;
Plante, J ;
Hivet, D ;
Kannengiesser, C ;
Naegelen, C ;
Joussemet, M ;
Marchesseau, B ;
Rasongles, P ;
Proust, F ;
David, C ;
Montembault, AM ;
Bergeat, P .
VOX SANGUINIS, 2003, 84 (04) :308-317
[7]   The anticoagulant function of coagulation factor V [J].
Cramer, Thomas J. ;
Gale, Andrew J. .
THROMBOSIS AND HAEMOSTASIS, 2012, 107 (01) :15-21
[8]   PREPARATION OF WHITE CELL-REDUCED PLATELET CONCENTRATES FROM WHOLE-BLOOD DURING COMPONENT PREPARATION [J].
DZIK, WH ;
CUSACK, WF ;
GACEK, MJ .
TRANSFUSION, 1991, 31 (06) :542-546
[9]  
European Committee, 2010, GUID PREP US QUAL AS
[10]   Plasma quality after whole-blood filtration depends on storage temperature and filter type [J].
Heiden, M ;
Salge, U ;
Henschler, R ;
Pfeiffer, HU ;
Volkers, P ;
Hesse, J ;
Sireis, W ;
Seitz, R .
TRANSFUSION MEDICINE, 2004, 14 (04) :297-304