Treatment of syndesmotic disruptions of the ankle with bioabsorbable screw fixation

被引:109
作者
Hovis, WD
Kaiser, BW
Watson, JT
Bucholz, RW
机构
[1] Hovis Orthopaed Clin, Knoxville, TN 37916 USA
[2] Univ Texas, SW Med Ctr, Sch Med, Dept Orthopaed Surg, Dallas, TX 75235 USA
[3] Anderson Orthopaed Clin, Anderson, SC 29631 USA
关键词
D O I
10.2106/00004623-200201000-00005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Bioabsorbable implants have restricted indications because of their unique biochemical properties and their inferior biomechanical properties compared with those of conventional metallic implants. The purpose of this prospective study was to assess the efficacy of screws made of polylevolactic acid (PLLA) in the treatment of syndesmotic disruptions associated with ankle fractures and fracture-dislocations. Methods: Thirty-three consecutive patients with a syndesmotic disruption were managed with standard metallic plate-and-screw fixation of the malleolar fracture and with 4.5-mm polylevolactic acid screws, with purchase in four cortices, for fixation of the syndesmosis. Intraoperative radiographs confirmed reduction of the syndesmosis, and all of the patients were managed with a non-weight-bearing plaster splint or brace for six weeks. Clinical and radiographic assessment and functional evaluation with use of the Olerud-Molander scoring system were performed at the time of follow-up. Results: Ten patients were lost to follow-up prior to the twenty-four-month evaluation, leaving twenty-three patients with an average duration of follow-up of thirty-four months (range, twenty-four to forty-three months). All of the malleolar fractures healed in an anatomical position at an average of three months, and no postoperative displacement of the syndesmosis or widening of the medial clear space was detectable on radiographs. No episodes of osteolysis or late inflammation secondary to the hydrolyzed polylactide occurred. Nineteen patients (83%) had an excellent result, and four patients (17%) had a good result. All twenty-three patients returned to their preinjury level of work and activities of daily living. No patient had malunion, nonunion, loss of reduction, or complications attributable to the biomechanical or biochemical properties of the implants. Conclusions: Polylevolactic acid screws are effective in stabilizing disruption of the syndesmosis during healing of unstable ankle fractures. In this small series, the bioabsorbable screw was well tolerated, and there was no need for a second operation to remove it.
引用
收藏
页码:26 / 31
页数:6
相关论文
共 27 条
[1]  
[Anonymous], 1979, Manual of Internal Fixation
[2]  
Blasier R D, 1997, Instr Course Lect, V46, P531
[3]   MECHANICAL CONSIDERATIONS FOR THE SYNDESMOSIS SCREW - A CADAVER STUDY [J].
BODEN, SD ;
LABROPOULOS, PA ;
MCCOWIN, P ;
LESTINI, WF ;
HURWITZ, SR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (10) :1548-1555
[4]   OSTEOLYTIC CHANGES ACCOMPANYING DEGRADATION OF ABSORBABLE FRACTURE FIXATION IMPLANTS [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04) :679-682
[5]  
BOSTMAN OM, 1995, CLIN ORTHOP RELAT R, P101
[6]   Late foreign-body reaction to an intraosseous bioabsorbable polylactic acid screw -: A case report [J].
Böstman, OM ;
Pihlajamaki, HK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (12) :1791-1794
[7]   ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :148-153
[8]   FIXATION WITH BIOABSORBABLE SCREWS FOR THE TREATMENT OF FRACTURES OF THE ANKLE [J].
BUCHOLZ, RW ;
HENRY, S ;
HENLEY, MB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (03) :319-324
[9]  
CHISSELL HR, 1995, J BONE JOINT SURG BR, V77B, P435
[10]  
CLAES L E, 1992, Clinical Materials, V10, P41, DOI 10.1016/0267-6605(92)90083-6