Three-Dimensional Local Measurements of Bone Strain and Displacement: Comparison of Three Digital Volume Correlation Approaches

被引:71
|
作者
Palanca, Marco [1 ]
Tozzi, Gianluca [2 ]
Cristofolini, Luca [3 ]
Viceconti, Marco [4 ,5 ]
Dall'Ara, Enrico [4 ,5 ]
机构
[1] Univ Bologna, Sch Engn & Architecture, I-40131 Bologna, Italy
[2] Univ Portsmouth, Sch Engn, Portsmouth PO1 3DJ, Hants, England
[3] Univ Bologna, Sch Engn & Architecture, I-40136 Bologna, Italy
[4] Univ Sheffield, Dept Mech Engn, Sheffield S1 3JD, S Yorkshire, England
[5] Univ Sheffield, INSIGNEO Inst Silico Med, Sheffield S1 3JD, S Yorkshire, England
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2015年 / 137卷 / 07期
关键词
digital volume correlation; registration; micro-CT; zero-strain test; bone; accuracy; precision; IMAGE REGISTRATION; EFFICIENT; ACCURACY;
D O I
10.1115/1.4030174
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Different digital volume correlation (DVC) approaches are currently available or under development for bone tissue micromechanics. The aim of this study was to compare accuracy and precision errors of three DVC approaches for a particular three-dimensional (3D) zero-strain condition. Trabecular and cortical bone specimens were repeatedly scanned with a micro-computed tomography (CT). The errors affecting computed displacements and strains were extracted for a known virtual translation, as well as for repeated scans. Three DVC strategies were tested: two local approaches, based on fast-Fourier-transform (DaVis-FFT) or direct-correlation (DaVis-DC), and a global approach based on elastic registration and a finite element (FE) solver (ShIRT-FE). Different computation subvolume sizes were tested. Much larger errors were found for the repeated scans than for the virtual translation test. For each algorithm, errors decreased asymptotically for larger subvolume sizes in the range explored. Considering this particular set of images, ShIRT-FE showed an overall better accuracy and precision (a few hundreds microstrain for a subvolume of 50 voxels). When the largest subvolume (50-52 voxels) was applied to cortical bone, the accuracy error obtained for repeated scans with ShIRT-FE was approximately half of that for the best local approach (DaVis-DC). The difference was lower (250 microstrain) in the case of trabecular bone. In terms of precision, the errors shown by DaVis-DC were closer to the ones computed by ShIRT-FE (differences of 131 microstrain and 157 microstrain for cortical and trabecular bone, respectively). The multipass computation available for DaVis software improved the accuracy and precision only for the DaVis-FFT in the virtual translation, particularly for trabecular bone. The better accuracy and precision of ShIRT-FE, followed by DaVis-DC, were obtained with a higher computational cost when compared to DaVis-FFT. The results underline the importance of performing a quantitative comparison of DVC methods on the same set of samples by using also repeated scans, other than virtual translation tests only. ShIRT-FE provides the most accurate and precise results for this set of images. However, both DaVis approaches show reasonable results for large nodal spacing, particularly for trabecular bone. Finally, this study highlights the importance of using sufficiently large subvolumes, in order to achieve better accuracy and precision.
引用
收藏
页数:14
相关论文
共 50 条
  • [42] Three-dimensional aneurysm volume measurements show no correlation between coil packing density and recurrence
    Thaci, Bart
    Nuno, Miriam
    Varshneya, Kunal
    Gerndt, Clayton H.
    Kercher, Matthew
    Dahlin, Brian C.
    Waldau, Ben
    HELIYON, 2020, 6 (10)
  • [43] The Displacement and Strain Field of Three-dimensional Rheologic Model of Earthquake Preparation
    Zhiping Song
    Xiangchu Yin
    Shirong Mei
    Yucang Wang
    Can Yin
    Huihui Zhang
    Langping Zhang
    pure and applied geophysics, 2006, 163 : 1991 - 2009
  • [44] The displacement and strain field of three-dimensional rheologic model of earthquake preparation
    Song, Zhiping
    Yin, Xiangchu
    Mei, Shirong
    Wang, Yucang
    Yin, Can
    Zhang, Huihui
    Zhang, Langping
    PURE AND APPLIED GEOPHYSICS, 2006, 163 (09) : 1991 - 2009
  • [45] Accuracy of three-dimensional transvaginal ultrasound in uterus volume measurements;: Comparison with two-dimensional ultrasound
    Yaman, C
    Jesacher, K
    Pölz, W
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (12): : 1681 - 1684
  • [46] Three-dimensional surface displacement tracking for in-situ experiments: An alternative to digital image correlation (DIC)
    El-Awady, Khalid A.
    Lavenstein, Steven
    El-Awady, Jaafar A.
    SCRIPTA MATERIALIA, 2023, 224
  • [47] Three-dimensional digital sonomicrometry: Comparison with biplane radiography
    Meoli, D
    Mazhari, R
    Dione, D
    Omens, J
    McCulloch, A
    Sinusas, A
    PROCEEDINGS OF THE IEEE 24TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 1998, : 64 - 67
  • [48] Dynamic measurements of internal three-dimensional displacement fields with digital speckle photography and flash x rays
    Synnergren, P
    Goldrein, HT
    APPLIED OPTICS, 1999, 38 (28) : 5956 - 5961
  • [49] Dynamic measurements of internal three-dimensional displacement fields with digital speckle photography and flash x rays
    Synnergren, Per
    Goldrein, H. Timothy
    Applied Optics, 1999, 38 (28): : 5956 - 5961
  • [50] Three-dimensional surface and volume measurements using a camera array