Electrochemical sensor for the detection of dopamine in the presence of ascorbic acid in neutral pH on graphitized nanoporous carbon modified glassy carbon electrode

被引:0
|
作者
Thangaraj, Rajendiran [1 ]
Mufeedah, Muringah Kandy [1 ]
Kumar, Annamalai Senthil [1 ]
机构
[1] Vellore Inst Technol Univ, Sch Adv Sci, Environm & Analyt Chem Div, Vellore 632014, Tamil Nadu, India
来源
RECENT TRENDS IN ADVANCED MATERIALS | 2012年 / 584卷
关键词
Nanoporous carbon; glassy carbon electrode; electrochemical detection; dopamine; ascorbic acid; URIC-ACID; BRAIN;
D O I
10.4028/www.scientific.net/AMR.584.334
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Selective detection of dopamine (DA) in presence of ascorbic (AA) is an important analytical problem, due to its combined existence in the biological system. In the present study, we are reporting an electrochemical detection of DA in the presence of AA using a graphitized nanoporous carbon (NPC) modified glassy carbon electrode (GCE/NPC) in pH 7 phosphate buffer solution. The GCE/NPC shows excellent electrocatalytic activity towards the oxidation of DA and AA in neutral pH. When compared to unmodified GCE, the GCE/NPC shows well separated and enhanced oxidation peak currents. Differential pulse voltammetric technique was used as qualitative analytical tool for the detection of DA. The oxidation peak potentials for AA and DA were at -80 and 136 mV vs Ag/AgCl respectively. The GCE/NPC shows good stability and reproducibility with the relative standard deviation value of 2.6 %. The analytical application of the GCE/NPC was demonstrated for the individual determination of DA in clinical injection and pharmaceutical tablet by using standard addition method.
引用
收藏
页码:334 / 338
页数:5
相关论文
共 50 条
  • [1] Poly (O-aminobenzoic acid) modified glassy carbon electrode for electrochemical detection of dopamine in the presence of ascorbic acid
    Zhang, YZ
    Jin, GY
    Cheng, WX
    Li, SP
    FRONTIERS IN BIOSCIENCE, 2005, 10 : 23 - 29
  • [2] Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine and Uric Acid Based on Nitrogen Doped Carbon Sphere Modified Glassy Carbon Electrode
    Ye, Fucheng
    Wen, Zubiao
    Wu, Hongfu
    Wang, Chunyan
    Qian, Yong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (02): : 1136 - 1143
  • [3] Determination of dopamine in the presence of ascorbic acid using poly(hippuric acid) modified glassy carbon electrode
    Zhao, H
    Zhang, YH
    Yuan, ZB
    ELECTROANALYSIS, 2002, 14 (14) : 1031 - 1034
  • [4] Polymethylthiophene/Nafion-modified glassy carbon electrode for selective detection of dopamine in the presence of ascorbic acid
    Huong, Vu Thi
    Shimanouchi, Toshinori
    Quan, Do Phuc
    Umakoshi, Hiroshi
    Viet, Pham Hung
    Kuboi, Ryoichi
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (10) : 2035 - 2042
  • [5] Polymethylthiophene/Nafion-modified glassy carbon electrode for selective detection of dopamine in the presence of ascorbic acid
    Vu Thi Huong
    Toshinori Shimanouchi
    Do Phuc Quan
    Hiroshi Umakoshi
    Pham Hung Viet
    Ryoichi Kuboi
    Journal of Applied Electrochemistry, 2009, 39 : 2035 - 2042
  • [6] Simultaneous electrochemical detection of uric acid and ascorbic acid at a silver doped poly(glutamic acid) modified glassy carbon electrode
    Sun, D. M.
    Hu, W. N.
    Ma, W.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (03) : 310 - 316
  • [7] Solar graphene modified glassy carbon electrode for the voltammetric resolution and detection of dopamine, ascorbic acid and uric acid
    Nancy, T. E. Mary
    Anithakumary, V.
    Swamy, B. E. Kumara
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 720 : 107 - 114
  • [8] Selective Determination of Dopamine and Uric Acid at Poly(acid red 176) Modified Glassy Carbon Electrode in the Presence of Ascorbic Acid
    Li, Xiao-bo
    Xu, Guang-ri
    Hu, Rui-yuan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (02): : 1920 - 1927
  • [9] Determination of dopamine in the presence of ascorbic acid using poly (acridine red) modified glassy carbon electrode
    Zhang, YZ
    Jin, GY
    Wang, YL
    Yang, ZS
    SENSORS, 2003, 3 (10): : 443 - 450
  • [10] Graphene oxide-Ag/poly-L-lysine modified glassy carbon electrode as an electrochemical sensor for the determination of dopamine in the presence of ascorbic acid
    Guo, Zhuo
    Huang, Guo-qing
    Li, Jian
    Wang, Ze-yu
    Xu, Xian-feng
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 759 : 113 - 121