Femoral press-fit fixation technique in anterior cruciate ligament reconstruction using bone-patellar tendon-bone graft -: A prospective clinical evaluation of 285 patients

被引:15
|
作者
Pavlik, A
Hidas, P
Tállay, A
Toman, J
Berkes, I
机构
[1] Natl Inst Sports Med, Dept Sports Surg, Budapest, Hungary
[2] Semmelweis Univ, Fac Sports Surg & Rehabil, Budapest, Hungary
关键词
ACL reconstruction; patellar tendon; press-fit fixation; follow-up study;
D O I
10.1177/0363546505279920
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The security of the graft fixation is an important factor of anterior cruciate ligament reconstruction, especially in the early postoperative period. Hypothesis: The femoral press-fit fixation technique is a safe, alternative technique for the fixation of the bone-patellar tendon-bone graft. Study Design: Case series; Level of evidence, 4. Methods: Between January 1, 1998, and June 30, 2002, 285 patients, with a mean age of 29.1 years, underwent operation and observation in our department. All patients had arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone graft with femoral press-fit and tibial interference screw fixation. The mean follow-up period was 35.8 months (range, 24-77 months). During each patient's evaluation, a physical examination, a subjective evaluation, the International Knee Documentation Committee and Lysholm scores, KT-1000 arthrometer testing, and radiological evaluation were performed. The 2 paired Student t test or chi(2) test was used for statistical analysis. Results: According to the International Knee Documentation Committee score, 241 patients (85%) had good (46 normal and 195 nearly normal) results, whereas 39 patients had abnormal and 5 patients had severely abnormal overall results. The preoperative mean Lysholm score was 63.5 +/- 12.7 points, At the final examination, the mean value was 93.5 +/- 7.8 points (P < .01). One hundred ninety-seven athletes could return to their previous sports activity level, whereas 13 patients gave up their sports career. The KT-1000 arthrometer results showed a side-to-side difference of 1.91 +/- 2.1 mm at the maximum manual strength tests. Conclusion: The femoral press-fit fixation is an alternative fixation method for the bone-patellar tendon-bone graft and provides good stability for the anterior cruciate ligament reconstruction. The use of press-fit fixation technique avoids most interference screw or other hardware-induced complications at the femoral side.
引用
收藏
页码:220 / 225
页数:6
相关论文
共 50 条
  • [21] Intraoperative fracture of patellar bone plug during anterior cruciate ligament reconstruction with bone-patellar tendon-bone: clinical case
    Salvi, Andrea Emilio
    Metelli, Giovanni Pietro
    Musella, Giovanni
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2007, 15 (01) : 58 - 60
  • [22] Comparisons of intraosseous graft healing between the doubled flexor tendon graft and the bone-patellar tendon-bone graft in anterior cruciate ligament reconstruction
    Tomita, F
    Yasuda, K
    Mikami, S
    Sakai, T
    Yamazaki, S
    Tohyama, H
    ARTHROSCOPY, 2001, 17 (05): : 461 - 476
  • [23] The transtibial versus the anteromedial portal technique in the arthroscopic bone-patellar tendon-bone anterior cruciate ligament reconstruction
    Alentorn-Geli, Eduard
    Lajara, Francisco
    Samitier, Gonzalo
    Cugat, Ramon
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (08) : 1013 - 1037
  • [24] The transtibial versus the anteromedial portal technique in the arthroscopic bone-patellar tendon-bone anterior cruciate ligament reconstruction
    Eduard Alentorn-Geli
    Francisco Lajara
    Gonzalo Samitier
    Ramón Cugat
    Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 1013 - 1037
  • [25] Intraoperative biomechanical evaluation of anatomic anterior cruciate ligament reconstruction using a navigation system - Comparison of hamstring tendon and bone-patellar tendon-bone graft
    Ishibashi, Yasuyuki
    Tsuda, Eiichi
    Fukuda, Akira
    Tsukada, Harhiko
    Toh, Satoshi
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2008, 36 (10) : 1903 - 1912
  • [26] Combined press-fit and extracortical fixation in patellar tendon anterior cruciate ligament reconstruction results in reliable graft fixation and early bone block incorporation
    Feichtinger, Xaver
    Muji, Edin
    Domej, Marija Ana
    Pauzenberger, Leo
    Baierl, Andreas
    Kocijan, Roland
    Loho, Gerald
    Brandl, Georg
    KNEE, 2023, 43 : 18 - 27
  • [27] Patellar tendon rupture 3 years after anterior cruciate ligament reconstruction with a central one third bone-patellar tendon-bone graft
    Mickelsen, PL
    Morgan, SJ
    Johnson, WA
    Ferrari, JD
    ARTHROSCOPY, 2001, 17 (06): : 648 - 652
  • [28] Effects of Bone-Patellar Tendon-Bone Autograft on Joint Position and Strength in Patients with Anterior Cruciate Ligament Reconstruction
    Alvarez-Ortiz, Isabel
    Silvestre, Rony
    Mahecha-Matsudo, Sandra
    Moran-Bravo, Matias
    Morales-Zuniga, Jorge
    Yanez-Sepulveda, Rodrigo
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2022, 40 (05): : 1186 - 1193
  • [29] Novel press-fit technique of patellar bone plug in anterior cruciate ligament reconstruction is comparable to interference screw fixation
    Janosch Häberli
    Maximilian Heilgemeir
    Sebastian Valet
    Ameet Aiyangar
    Tom Overes
    Philipp Henle
    Stefan Eggli
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 1963 - 1970
  • [30] A technique for resolution of graft-tunnel length mismatch in central third bone-patellar tendon-bone anterior cruciate ligament reconstruction
    Auge, WK
    Yifan, K
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1999, 15 (08) : 877 - 881