State-of-the art data normalization methods improve NMR-based metabolomic analysis

被引:163
作者
Kohl, Stefanie M. [1 ]
Klein, Matthias S. [1 ]
Hochrein, Jochen [1 ]
Oefner, Peter J. [1 ]
Spang, Rainer [1 ]
Gronwald, Wolfram [1 ]
机构
[1] Univ Regensburg, Inst Funct Genom, D-93053 Regensburg, Germany
关键词
Metabolomics; NMR; Data normalization; Preprocessing; Classification; H-1-NMR; SPECTROSCOPY; METABONOMICS; PROTEOMICS; ALIGNMENT; VARIANCE; URINE;
D O I
10.1007/s11306-011-0350-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Extracting biomedical information from large metabolomic datasets by multivariate data analysis is of considerable complexity. Common challenges include among others screening for differentially produced metabolites, estimation of fold changes, and sample classification. Prior to these analysis steps, it is important to minimize contributions from unwanted biases and experimental variance. This is the goal of data preprocessing. In this work, different data normalization methods were compared systematically employing two different datasets generated by means of nuclear magnetic resonance (NMR) spectroscopy. To this end, two different types of normalization methods were used, one aiming to remove unwanted sample-to-sample variation while the other adjusts the variance of the different metabolites by variable scaling and variance stabilization methods. The impact of all methods tested on sample classification was evaluated on urinary NMR fingerprints obtained from healthy volunteers and patients suffering from autosomal polycystic kidney disease (ADPKD). Performance in terms of screening for differentially produced metabolites was investigated on a dataset following a Latin-square design, where varied amounts of 8 different metabolites were spiked into a human urine matrix while keeping the total spike-in amount constant. In addition, specific tests were conducted to systematically investigate the influence of the different preprocessing methods on the structure of the analyzed data. In conclusion, preprocessing methods originally developed for DNA microarray analysis, in particular, Quantile and Cubic-Spline Normalization, performed best in reducing bias, accurately detecting fold changes, and classifying samples.
引用
收藏
页码:S146 / S160
页数:15
相关论文
共 39 条
  • [1] MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES
    ALTMAN, DG
    BLAND, JM
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) : 307 - 317
  • [2] Quantifying reproducibility for differential proteomics: noise analysis for protein liquid chromatography-mass spectrometry of human serum
    Anderle, M
    Roy, S
    Lin, H
    Becker, C
    Joho, K
    [J]. BIOINFORMATICS, 2004, 20 (18) : 3575 - 3582
  • [3] [Anonymous], R LANG ENV STAT COMP
  • [4] [Anonymous], 2003, User's Guide to Principal Components
  • [5] Contrast normalization of oligonucleotide arrays
    Åstrand, M
    [J]. JOURNAL OF COMPUTATIONAL BIOLOGY, 2003, 10 (01) : 95 - 102
  • [6] A comparison of normalization methods for high density oligonucleotide array data based on variance and bias
    Bolstad, BM
    Irizarry, RA
    Åstrand, M
    Speed, TP
    [J]. BIOINFORMATICS, 2003, 19 (02) : 185 - 193
  • [7] Metabolic Profiling as a Tool for Understanding Mechanisms of Toxicity
    Clarke, Christopher J.
    Haselden, John N.
    [J]. TOXICOLOGIC PATHOLOGY, 2008, 36 (01) : 140 - 147
  • [8] LOCALLY WEIGHTED REGRESSION - AN APPROACH TO REGRESSION-ANALYSIS BY LOCAL FITTING
    CLEVELAND, WS
    DEVLIN, SJ
    [J]. JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1988, 83 (403) : 596 - 610
  • [9] Statistical total correlation spectroscopy:: An exploratory approach for latent biomarker identification from metabolic 1H NMR data sets
    Cloarec, O
    Dumas, ME
    Craig, A
    Barton, RH
    Trygg, J
    Hudson, J
    Blancher, C
    Gauguier, D
    Lindon, JC
    Holmes, E
    Nicholson, J
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (05) : 1282 - 1289
  • [10] Evaluation of the orthogonal projection on latent structure model limitations caused by chemical shift variability and improved visualization of biomarker changes in 1H NMR spectroscopic metabonomic studies
    Cloarec, O
    Dumas, ME
    Trygg, J
    Craig, A
    Barton, RH
    Lindon, JC
    Nicholson, JK
    Holmes, E
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (02) : 517 - 526