Impact of CT attenuation correction by SPECT/CT in brain perfusion images

被引:24
|
作者
Ishii, Kazunari [1 ]
Hanaoka, Kohei [1 ]
Okada, Masahiro [1 ]
Kumano, Seishi [1 ]
Komeya, Yoshihiro [1 ]
Tsuchiya, Norio [1 ]
Hosono, Makoto [1 ]
Murakami, Takamichi [1 ]
机构
[1] Kinki Univ, Fac Med, Dept Radiol, Osaka 5898511, Japan
关键词
SPECT/CT; Brain perfusion; Attenuation correction; Chang's method; SCATTER CORRECTION; NONUNIFORM;
D O I
10.1007/s12149-011-0567-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to elucidate the regional differences between brain perfusion single photon emission computed tomography (SPECT) images reconstructed with a uniform attenuation correction using Chang's method (AC-Chang) and a non-uniform attenuation correction with CT using SPECT/CT (AC-CT). SPECT images of a phantom with and without head holder were obtained, and reconstructed images of AC-Chang and AC-CT were compared. Twenty-eight consecutive patients with brain disease examined by SPECT/CT brain perfusion imaging were selected, and images were reconstructed with AC-Chang and AC-CT. The AC-Chang and AC-CT reconstructed images were then compared by voxel-based analysis using three-dimensional stereotactic surface projections. Counts in the frontal area of the AC-Chang phantom image with head holder were higher than those in the posterior area. Counts in the frontal area of the AC-Chang clinical images were significantly higher than those in the AC-CT images, while the counts in the margin of the frontal lobe and posterior margin of the parietal, occipital cortices and cerebellum of the AC-Chang images were significantly lower. Relative frontal perfusion was 5.0% higher and relative cerebellar perfusion was 4.6% lower in the AC-Chang images relative to the AC-CT images, on average. We demonstrated the frontal dominant hyper-perfusion and parieto-occipital and cerebellar hypo-perfusion in brain SPECT images reconstructed with AC-Chang compared to those reconstructed with AC-CT. We suggest that to obtain an accurate attenuation-corrected brain perfusion SPECT image, attenuation correction by Chang's method is inadequate.
引用
收藏
页码:241 / 247
页数:7
相关论文
共 50 条
  • [31] Would SPECT/CT be a must for attenuation correction in gated-SPECT myocardial perfusion imaging?
    Ali, L.
    Al-Saffar, A.
    Loutfi, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S533 - S533
  • [32] The Role of the Attenuation Correction by ECG-GATED Myocardial Perfusion SPECT/CT
    Radacsi, A.
    Olbrich, Z.
    Balogh, I.
    Ronaszeki, A.
    Ronaszeki, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S538 - S539
  • [33] Single CT for attenuation correction of rest/stress cardiac SPECT perfusion imaging
    R. Glenn Wells
    Mikael Trottier
    Manuja Premaratne
    Karen Vanderwerf
    Terrence D. Ruddy
    Journal of Nuclear Cardiology, 2018, 25 : 616 - 624
  • [34] Attenuation correction in myocardial perfusion SPECT/CT: Effects of misregistration and value of reregistration
    Goetze, Sibyll
    Brown, Tracy L.
    Lavely, William C.
    Zhang, Zhe
    Bengel, Frank M.
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (07) : 1090 - 1095
  • [35] CT attenuation correction of spect myocardial perfusion scintigraphy improves diagnostic accuracy
    Wright, G.
    Cockburn, K.
    Davies, G.
    Avery, G.
    Tweddel, A.
    HEART, 2007, 93 : A97 - A97
  • [36] V/P-SPECT-CT: Influence of attenuation correction on the homogeneity of lung perfusion SPECT
    Knollmann, Daniela
    Meyer, Philipp
    Meyer, Andreas
    Schaefer, Wolfgang
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [37] Single CT for attenuation correction of rest/stress cardiac SPECT perfusion imaging
    Dewan, Ambuj
    Ali, Iftikhar
    Ruddy, Terrence
    Wells, R.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [38] Myocardial perfusion SPECT with CT attenuation correction: Role of misregistration and value of reregistration
    Goetze, Sibyll
    Brown, Tracy L.
    Lavely, William C.
    Zhang, Zhe
    Bengel, Frank M.
    CIRCULATION, 2006, 114 (18) : 582 - 582
  • [39] SPECT and CT misalignment in myocardial perfusion scintigraphy with attenuation correction: effect of CT realignment on study result
    Siennicki, J.
    Raciborska, I.
    Kovacevic-Kusmierek, K.
    Chizynski, K.
    Kusmierek, J.
    Plachcinska, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S263 - S264
  • [40] Effect of CT attenuation correction on striatal 123I-ioflupane uptake evaluation: A quantitative comparison using brain SPECT and SPECT/CT images
    Vejdani, Kaveh
    Gandhi, Harsh
    Hewing, Debra
    Muzaffar, Razi
    Osman, Medhat
    Chand, Pratap
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55