Impact of CT attenuation correction by SPECT/CT in brain perfusion images

被引:24
|
作者
Ishii, Kazunari [1 ]
Hanaoka, Kohei [1 ]
Okada, Masahiro [1 ]
Kumano, Seishi [1 ]
Komeya, Yoshihiro [1 ]
Tsuchiya, Norio [1 ]
Hosono, Makoto [1 ]
Murakami, Takamichi [1 ]
机构
[1] Kinki Univ, Fac Med, Dept Radiol, Osaka 5898511, Japan
关键词
SPECT/CT; Brain perfusion; Attenuation correction; Chang's method; SCATTER CORRECTION; NONUNIFORM;
D O I
10.1007/s12149-011-0567-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to elucidate the regional differences between brain perfusion single photon emission computed tomography (SPECT) images reconstructed with a uniform attenuation correction using Chang's method (AC-Chang) and a non-uniform attenuation correction with CT using SPECT/CT (AC-CT). SPECT images of a phantom with and without head holder were obtained, and reconstructed images of AC-Chang and AC-CT were compared. Twenty-eight consecutive patients with brain disease examined by SPECT/CT brain perfusion imaging were selected, and images were reconstructed with AC-Chang and AC-CT. The AC-Chang and AC-CT reconstructed images were then compared by voxel-based analysis using three-dimensional stereotactic surface projections. Counts in the frontal area of the AC-Chang phantom image with head holder were higher than those in the posterior area. Counts in the frontal area of the AC-Chang clinical images were significantly higher than those in the AC-CT images, while the counts in the margin of the frontal lobe and posterior margin of the parietal, occipital cortices and cerebellum of the AC-Chang images were significantly lower. Relative frontal perfusion was 5.0% higher and relative cerebellar perfusion was 4.6% lower in the AC-Chang images relative to the AC-CT images, on average. We demonstrated the frontal dominant hyper-perfusion and parieto-occipital and cerebellar hypo-perfusion in brain SPECT images reconstructed with AC-Chang compared to those reconstructed with AC-CT. We suggest that to obtain an accurate attenuation-corrected brain perfusion SPECT image, attenuation correction by Chang's method is inadequate.
引用
收藏
页码:241 / 247
页数:7
相关论文
共 50 条
  • [1] Impact of CT attenuation correction by SPECT/CT in brain perfusion images
    Kazunari Ishii
    Kohei Hanaoka
    Masahiro Okada
    Seishi Kumano
    Yoshihiro Komeya
    Norio Tsuchiya
    Makoto Hosono
    Takamichi Murakami
    Annals of Nuclear Medicine, 2012, 26 : 241 - 247
  • [2] Clinical impact of CT attenuation correction by SPECT/CT in brain perfusion images
    Ishii, Kazunari
    Hanaoka, Kohei
    Okada, Masahiro
    Kumano, Seishi
    Komeya, Yoshihiro
    Tsuchiya, Norio
    Hosono, Makoto
    Murakami, Takamichi
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [3] Impact of CT Attenuation Correction in SPECT Myocardial Perfusion Imaging
    Vlachou, F.
    Nikaki, A.
    Gogos, K.
    Tsiakas, E.
    Papoutsani, D.
    Giannis, D.
    Gogou, L.
    Prassopoulos, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S317 - S317
  • [4] Respiratory average CT for attenuation correction in myocardial perfusion SPECT/CT
    Duo Zhang
    Bang-Hung Yang
    Nien Yun Wu
    Greta Seng Peng Mok
    Annals of Nuclear Medicine, 2017, 31 : 172 - 180
  • [5] Respiratory average CT for attenuation correction in myocardial perfusion SPECT/CT
    Zhang, Duo
    Yang, Bang-Hung
    Wu, Nien Yun
    Mok, Greta Seng Peng
    ANNALS OF NUCLEAR MEDICINE, 2017, 31 (02) : 172 - 180
  • [6] Respiration Average CT for Myocardial Perfusion SPECT/CT Attenuation Correction
    Mok, Greta S. P.
    Zhang, Duo
    Ho, Cobie Y. T.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [7] CT-attenuation correction in myocardial perfusion SPECT using a hybrid SPECT/CT
    Namdar, M
    Siegrist, PT
    Koepfli, P
    Tschuetscher, P
    Hany, TF
    Kaufmann, PA
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S261 - S261
  • [8] Impact of CT-based attenuation and scatter correction on myocardial SPECT images
    van Dalen, J. A.
    Sellis, M.
    de Bruin, W. I.
    Wyndaele, D. N. J.
    Slump, C. H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S286 - S286
  • [9] Clinical Impact of Nonuniform CT-Based Attenuation Correction in Brain Perfusion SPECT/CT Using 99mTc-ECD
    Farid, Karim
    Petras, Slavomir
    Poullias, Xavier
    Caillat-Vigneron, Nadine
    CLINICAL NUCLEAR MEDICINE, 2014, 39 (06) : E343 - E345
  • [10] Diagnostic Performance Of Myocardial Perfusion SPECT/CT With Attenuation Correction
    Mammeri, S.
    Mansouri, F.