Diagnostic use of macular layer analysis by SD-OCT in primary open angle glaucoma

被引:0
|
作者
Delbarre, M. [1 ]
El Chehab, H. [1 ]
Francoz, M. [1 ]
Zerrouk, R. [1 ]
Marechal, M. [1 ]
Marill, A. F. [1 ]
Giraud, J. -M. [1 ]
May, F. [1 ]
Renard, J. -P. [1 ]
机构
[1] Hop Instruct Armees Val de Grace, Serv Ophtalmol, F-75230 Paris 5, France
来源
JOURNAL FRANCAIS D OPHTALMOLOGIE | 2013年 / 36卷 / 09期
关键词
Glaucoma; Optical coherence tomography; SD-OCT; Ganglion cell complex; GCC; GCIPL; OPTICAL COHERENCE TOMOGRAPHY; GANGLION-CELL LOSS; EYES; THICKNESS; ACCURACY;
D O I
10.1016/j.jfo.2013.08.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. - The purpose of this study is to evaluate the diagnostic ability of segmentation of the various internal macular layers by spectral domain optical coherence tomography (Cirrus HD-OCT, Carl Zeiss Meditec (CZM), Dublin, CA, USA) and to compare it to that of the peripapillary retinal nerve fiber layer (cpRNFL) in primary open angle glaucoma (POAG). Materials and methods. - This study included 252 eyes diagnosed with primary open angle glaucoma (POAG) (164 early POAG, 44 moderate POAG and 44 advanced POAG) and 223 eyes of control subjects. All patients underwent visual field testing (Humphrey Field Analyser, SITA-Standard 24-2, CZM), and SD-OCT imaging (Cirrus HD-OCT) of the macular and optic nerve head regions (ganglion cell analysis (GCA), macular cube 200 x 200; optic disc cube 200 x 200). OCT macular scans were segmented into macular nerve fiber layer (mNFL), ganglion cell layer with inner plexiform layer (GCIPL), outer retinal layers, and ganglion cell complex (GCC) (mNFL + GCIPL). Glaucoma discriminating ability was assessed using the area under the receiver operator characteristic curve (AUC) for all macular parameters and mean circumpapillary retinal nerve fibre layer (cpRNFL). Results. - For the entire POAG population of this study, the minimum GCIPL index provided greater diagnostic ability than the other parameters studied, with a statistically significant difference in their AUC (minimum GCIPL [0.887], mean GCIPL [0.865], GCC [0.863], cpRNFL [0.823], mean mNFL [0.786] and minimum mNFL [0.742]). The results were similar in the early POAG group but without any statistically significant difference with the cpRNFL parameter. In the moderate POAG group, the diagnostic ability was similar for all indices, whereas in the advanced POAG group, minimum GCIPL and GCC gave the largest AUC indices. Discussion and conclusion. - The minimum macular GCIPL is a new index obtained with the GCA algorithm of the Cirrus HD-OCT. It appears to have an excellent ability to detect glaucoma at every stage and demonstrates performance comparable to that of the cpRNFL parameter, in combination with which it may provide important complementary information for clinical practice. (C) 2013 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:723 / 731
页数:9
相关论文
共 50 条
  • [31] Artificial intelligence for the detection of glaucoma with SD-OCT images: a systematic review and Meta-analysis
    Shi, Nan-Nan
    Li, Jing
    Liu, Guang-Hui
    Cao, Ming-Fang
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (03) : 408 - 419
  • [32] OCT Angiography of the Peripapillary Retina in Primary Open-Angle Glaucoma
    Lee, Eun Ji
    Lee, Kyoung Min
    Lee, Seung Hyen
    Kim, Tae-Woo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (14) : 6265 - 6270
  • [33] Diagnostic capability of macular parameters of Stratus OCT 3 in detection of early glaucoma
    Parikh, R. S.
    Parikh, S. R.
    Thomas, R.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (02) : 197 - 201
  • [34] Peripapillary Choroidal Thickness and Choroidal Area in Glaucoma, Ocular Hypertension and Healthy Subjects by SD-OCT
    Lamparter, J.
    Schulze, A.
    Riedel, J.
    Wasielica-Poslednik, J.
    Koenig, J.
    Pfeiffer, N.
    Hoffmann, E. M.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (04) : 390 - 394
  • [35] Comparative Evaluation of Two SD-OCT Macular Parameters (GCC, GCL) and RNFL in Chiasmal Compression
    Santorini, Melissa
    De Moura, Thomas Ferreira
    Barraud, Sara
    Litre, Claude Fabien
    Brugniart, Catherine
    Denoyer, Alexandre
    Djerada, Zoubir
    Arndt, Carl
    EYE AND BRAIN, 2022, 14 : 35 - 48
  • [36] The Optimal Diameter for Circumpapillary Retinal Nerve Fiber Layer Thickness Measurement by SD-OCT in Glaucoma
    Heindl, Ludwig M.
    Adler, Werner
    El-Malahi, Ouahiba
    Schaub, Friederike
    Hermann, Manuel M.
    Dietlein, Thomas S.
    Cursiefen, Claus
    Enders, Philip
    JOURNAL OF GLAUCOMA, 2018, 27 (12) : 1086 - 1093
  • [37] Macular Thickness Measurement via Heidelberg Spectralis SD-OCT in Pediatric Patients
    Yilmaz, Ihsan
    Ozkaya, Abdullah
    Alkin, Zeynep
    Perente, Irfan
    Alagoz, Cengiz
    Yazici, Ahmet Taylan
    OPHTHALMOLOGICA, 2014, 232 : 50 - 51
  • [38] The Whole Macular Choroidal Thickness in Subjects with Primary Open Angle Glaucoma
    Nakakura, Shunsuke
    Yamamoto, Minami
    Terao, Etsuko
    Nagasawa, Toshihiko
    Tabuchi, Hitoshi
    Kiuchi, Yoshiaki
    PLOS ONE, 2014, 9 (10):
  • [39] SD-OCT Use in Myopic Retinoschisis Pre- and Post-Vitrectomy
    Wang, Shiyuan
    Peng, Qing
    Zhao, Peiquan
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (05) : 678 - 683
  • [40] A new diagnostic model of primary open angle glaucoma based on FD-OCT parameters
    Ya-Jie Zheng
    Ying-Zi Pan
    Xue-Ying Li
    Yuan Fang
    Mei Li
    Rong-Hua Qiao
    Yu Cai
    International Journal of Ophthalmology, 2018, (06) : 951 - 957