Experimental investigations of the swirling flow in the conical diffuser using flow-feedback control technique with additional energy source

被引:4
|
作者
Tanasa, C. [1 ]
Bosioc, A. I.
Susan-Resiga, R. F. [1 ]
Muntean, S.
机构
[1] Polytech Univ, Dept Hydraul Machinery, Timisoara, Romania
来源
26TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, PTS 1-7 | 2013年 / 15卷
关键词
D O I
10.1088/1755-1315/15/6/062043
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The previous experimental and numerical investigations of decelerated swirling flows in conical diffusers have demonstrated that water injection along to the axis mitigates the pressure fluctuations associated to the precessing vortex rope [1]. However, for swirling flows similar to Francis turbines operated at partial discharge, the water jet becomes effective when the jet discharge is larger than 10% from the turbine discharge, leading to large volumetric losses when the jet is supplied from upstream the runner. As a result, it was introduced a new approach for supplying the jet by using a fraction of the discharge collected downstream the conical diffuser [2]. This is called flow-feedback control technique (FFCT) and it was investigated experimentally in order to assess its capability [3]. The FFCT approach not requires additional energy to supply the jet. Consequently, the turbine efficiency is not diminished due to the volumetric losses injected even if around 10% of the main flow is used. However, the equivalent amplitude of the pressure pulsations associated to the vortex rope decreases with 30% if 10% jet discharge is applied [3]. Using 12% water jet discharge from upstream then the equivalent amplitude of the pressure pulsations is mitigated with 70% according to Bosioc et al. [4]. In our case, an extra 2% jet discharge is required in order to obtain similar results with FFCT. This extra discharge is provided using an additional energy source. Therefore, the paper presents experimental investigation performed with FFCT with additional energy source. The experimental results obtained with this technique are compared against FFCT and the swirling flow with vortex rope, respectively.
引用
收藏
页数:10
相关论文
共 39 条
  • [1] FLOW-FEEDBACK CONTROL TECHNIQUE FOR VORTEX ROPE MITIGATION FROM CONICAL DIFFUSER OF HYDRAULIC TURBINES DRAFT TUBE
    Tanasa, Constantin
    Bosioc, Alin I.
    Muntean, Sebastian
    Susan-Resiga, Romeo F.
    PROCEEDINGS OF THE ROMANIAN ACADEMY SERIES A-MATHEMATICS PHYSICS TECHNICAL SCIENCES INFORMATION SCIENCE, 2011, 12 (02): : 125 - 132
  • [2] Numerical and experimental investigation of swirling flow in a conical diffuser
    David, Stefan
    Pavel, Zubik
    Martin, Hudec
    Pavel, Rudolf
    EFM14 - EXPERIMENTAL FLUID MECHANICS 2014, 2015, 92
  • [3] THEORETICAL AND EXPERIMENTAL INVESTIGATION OF THE TURBULENT SWIRLING FLOW CHARACTERISTICS IN A CONICAL DIFFUSER
    BENISEK, M
    CANTRAK, S
    NEDELJKOVIC, M
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 1991, 71 (05): : T453 - T456
  • [4] PRESSURE RECOVERY IMPROVEMENT IN A CONICAL DIFFUSER WITH SWIRLING FLOW USING WATER JET INJECTION
    Bosioc, Alin I.
    Tanasa, Constantin
    Muntean, Sebastian
    Susan-Resiga, Romeo F.
    PROCEEDINGS OF THE ROMANIAN ACADEMY SERIES A-MATHEMATICS PHYSICS TECHNICAL SCIENCES INFORMATION SCIENCE, 2010, 11 (03): : 245 - 252
  • [5] Unsteady pressure measurements and numerical investigation of the jet control method in a conical diffuser with swirling flow
    Bosioc, A. I.
    Tanasa, C.
    Muntean, S.
    Susan-Resiga, R. F.
    25TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, 2010, 12
  • [6] Experimental study of swirling flow from conical diffusers using the water jet control method
    Bosioc, Alin Ilie
    Tanasa, Constantin
    RENEWABLE ENERGY, 2020, 152 : 385 - 398
  • [7] A Perspective Review of Passive Techniques Applied to Control the Swirling Flow Instabilities From the Conical Diffuser of Hydraulic Turbines
    Tanasa, Constantin
    Bosioc, Alin
    Stuparu, Adrian
    Muntean, Sebastian
    Susan-Resiga, Romeo
    APPLIED MECHANICS REVIEWS, 2024, 76 (01)
  • [8] Reconstruction of numerical inlet boundary conditions using machine learning: Application to the swirling flow inside a conical diffuser
    Veras, Pedro
    Balarac, Guillaume
    Metais, Olivier
    Georges, Didier
    Bombenger, Antoine
    Segoufin, Claire
    PHYSICS OF FLUIDS, 2021, 33 (08)
  • [9] A Novel Passive Method to Control the Swirling Flow with Vortex Rope from the Conical Diffuser of Hydraulic Turbines with Fixed Blades
    Tanasa, Constantin
    Bosioc, Alin
    Muntean, Sebastian
    Susan-Resiga, Romeo
    APPLIED SCIENCES-BASEL, 2019, 9 (22):
  • [10] COMPRESSIBLE CONICAL DIFFUSER FLOW USING ENERGY DEFICIT BOUNDARY-LAYER METHOD
    LIVESEY, JL
    ODUKWE, AO
    KAMAL, WA