Detection of salmonella in poultry using a silicon chip-based biosensor

被引:55
作者
Dill, K
Stanker, LH
Young, CR
机构
[1] Mol Devices Corp, Sunnyvale, CA 94089 USA
[2] USDA ARS, Food Anim Protect Res Lab, Food & Feed Safety Unit, College Stn, TX 77845 USA
来源
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS | 1999年 / 41卷 / 01期
关键词
Salmonella; poultry; Light-Addressable Potentiometric Sensor (LAPS); silicon chip;
D O I
10.1016/S0165-022X(99)00027-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Salmonella typhimurium was detected to levels as low as 119 CFUs using the Threshold(R) Immunoassay System. This immunoassay system utilizes solution-based binding of the biotin and fluorescein labeled antibodies to salmonella, followed by filtration-capture of the immunocomplex on a biotin-coated nitrocellulose membrane. Lastly, an anti-fluorescein urease conjugate is bound to the immunocomplex. Detection of the bound immunocomplex is made possible via the silicon chip-based light-addressable potentiometric sensor. In the presence of the urea, urease converts the substrate to ammonia and CO2 and this results in a pH change at the silicon surface. The resultant pH change is monitored with time and the signal output is reported in mu V s(-1). An experiment whereby chicken carcass washings were fortified with salmonella showed a recovery of 90%, indicating that the technique can be used to test for salmonella under these conditions. Precautions must be used with this instrument as sample debris will affect sample flow through the membrane and hence the signal output. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 10 条
  • [1] EXPERIMENTAL ENZYME-LINKED AMPEROMETRIC IMMUNOSENSORS FOR THE DETECTION OF SALMONELLAS IN FOODS
    BROOKS, JL
    MIRHABIBOLLAHI, B
    KROLL, RG
    [J]. JOURNAL OF APPLIED BACTERIOLOGY, 1992, 73 (03): : 189 - 196
  • [2] Rapid, sensitive and specific detection of whole cells and spores using the light-addressable potentiometric sensor
    Dill, K
    Song, JH
    Blomdahl, JA
    Olson, JD
    [J]. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1997, 34 (02): : 161 - 166
  • [3] Dill K, 1996, ACS SYM SER, V646, P89
  • [4] DILL K, 1996, P IMM 5 JOINT C ENV, P59
  • [5] DILL K, 1997, TECHNIQUES GLYCOBIOL, P229
  • [6] Enzyme-linked immunomagnetic electrochemical detection of Salmonella typhimurium
    Gehring, AG
    Crawford, CG
    Mazenko, RS
    VanHouten, LJ
    Brewster, JD
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1996, 195 (1-2) : 15 - 25
  • [7] Merrick H., 1992, BIOTECH FORUM EUR, V6, P398
  • [8] Panfili Peter R., 1994, Current Opinion in Biotechnology, V5, P60, DOI 10.1016/S0958-1669(05)80071-0
  • [9] SOUMET C, 1995, BIOTECHNIQUES, V19, P792
  • [10] Immunomagnetic-electrochemiluminescent detection of Escherichia coli O157 and Salmonella typhimurium in foods and environmental water samples
    Yu, H
    Bruno, JG
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1996, 62 (02) : 587 - 592