Nerve conduction and sensorineural function in dental hygienists using high frequency ultrasound handpieces

被引:26
作者
Cherniack, M
Brammer, AJ
Nilsson, T
Lundstrom, R
Meyer, JD
Morse, T
Neely, G
Peterson, D
Toppila, E
Warren, N
Atwood-Sanders, M
Michalak-Turcotte, C
Abbas, U
Bruneau, H
Croteau, M
Fu, RW
机构
[1] Univ Connecticut, Ctr Hlth, Ergonom Technol Ctr, Farmington, CT 06030 USA
[2] CNR, Inst Microstruct Sci, Ottawa, ON, Canada
[3] Sundsvall Hosp, Dept Occupat & Environm Med, Sundsvall, Sweden
[4] Univ Umea Hosp, Dept Biomed Engn & Informat, Umea, Sweden
[5] Tech Risk Factors, Natl Inst Working Life, Umea, Sweden
[6] Finnish Inst Occupat Hlth, Dept Phys, Helsinki, Finland
关键词
vibrotactile threshold; sensory nerve conduction velocity; ultrasonics; dental hygienists;
D O I
10.1002/ajim.20288
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background Oscillatory vibration from industrial power tools poses a well-recognized risk of peripheral nerve injury. There have been reports of elevated vibrotactile perception thresholds (VPT) among dentists, dental technicians, and dental hygienists, using rotary devices and ultrasonics. Elevated VPTs are an indicator of small fiber nerve or mechanoreceptor injury, but the high frequencies associated with dental instruments are presumed by the ISO to exceed physiological response upper thresholds. This study examines nerve conduction and sensorineural deficits in dental hygienists. Methods A cross-sectional study of 94 experienced dental hygienists was conducted to assess peripheral nerve function and clinical signs and symptoms. Specialized testing included measurement of VPTs for three different categories of mechanoreceptors, sensory nerve conduction tests with fractionated digit and palmar segments, and measurement of calibrated pinch force with force sensitive resistors (FSRs) during a simulated procedure. Results Chronic hand paresthesias were described by 44.7% of experienced dental hygienists. Sensory nerve conduction velocity (SNCV) across the wrist-palm segment of the median nerve. VPTs were particularly elevated at the FAII mechanoreceptor among experienced dental hygienists. Compared to participants without carpal tunnel syndrome (CTS), as defined by study criteria, 14 experienced hygienists with diagnosed CTS had almost twice the average weekly use of vibratory instruments -8.3 hr versus 4.5 hr, and had SNCV deficits along the digit -47.11 m/sec (+8.70) versus 42.57 m/sec (+8.25), and across the wrist -44.04 m/sec (+7.15) versus 41.36 m/sec (+9.27). There was a distinct subset of dental hygienists (27%) with a combination of low calibrated pinch force in simulations, subjective loss of strength and elevated VPTs, especially in the FAH mechanoreceptor population -110.82 db (+8.57) versus 104.84 db (+680) in the rest of the cohort. This subset also had a higher prevalence of paresthesias (67% vs. 39%) and greater cumulative vibration exposure (OR = 1.206 [CI 1.005-1.448]), than other hygienists. Conclusions The high levels of paresthesias observed among dental hygienists appear to be attributable to several pathophysiological mechanisms, including, sensory nerve demyelination at the carpal tunnel and intrinsic to the digits, and dysfunction of fingertip mechanoreceptors. A distinct sub-population appears to exhibit a high level of accumulated abnormality.
引用
收藏
页码:313 / 326
页数:14
相关论文
共 42 条
  • [11] Conrad J C, 1993, J Dent Hyg, V67, P268
  • [12] SENSORY PERCEPTION IN THE HANDS OF DENTISTS
    EKENVALL, L
    NILSSON, BY
    FALCONER, C
    [J]. SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1990, 16 (05) : 334 - 339
  • [13] VIBRATION-INDUCED DECREASE IN THE MUSCLE FORCE IN LUMBERJACKS
    FARKKILA, M
    PYYKKO, I
    KORHONEN, O
    STARCK, J
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1980, 43 (01): : 1 - 9
  • [14] HANDGRIP FORCE IN LUMBERJACKS - 2-YEAR FOLLOW-UP
    FARKKILA, M
    AATOLA, S
    STARCK, J
    KORHONEN, O
    PYYKKO, I
    [J]. INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1986, 58 (03) : 203 - 208
  • [15] THE STOCKHOLM WORKSHOP SCALE FOR THE CLASSIFICATION OF COLD-INDUCED RAYNAUDS-PHENOMENON IN THE HAND-ARM VIBRATION SYNDROME (REVISION OF THE TAYLOR-PELMEAR SCALE)
    GEMNE, G
    PYYKKO, I
    TAYLOR, W
    PELMEAR, PL
    [J]. SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1987, 13 (04) : 275 - 278
  • [16] GEMNE G, 1994, HAND ARM VIBRATION C, P41
  • [17] SENSITIVITY AND SPECIFICITY OF VIBROMETRY FOR DETECTION OF CARPAL-TUNNEL SYNDROME
    GERR, F
    LETZ, R
    HARRISABBOTT, D
    HOPKINS, LC
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1995, 37 (09) : 1108 - 1115
  • [18] Gerwatowski L J, 1992, J Dent Hyg, V66, P89
  • [19] Griffin MJ, 2002, INT ARCH OCC ENV HEA, V75, P1
  • [20] FINGER RECEPTOR DYSFUNCTION IN DENTAL-TECHNICIANS EXPOSED TO HIGH-FREQUENCY VIBRATION
    HJORTSBERG, U
    ROSEN, I
    ORBAEK, P
    LUNDBORG, G
    BALOGH, I
    [J]. SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1989, 15 (05) : 339 - 344