Seismic response of full-scale structure with added viscoelastic dampers

被引:45
|
作者
Chang, KC
Lin, YY
机构
[1] Natl Taiwan Univ, Dept Civil Engn, Taipei 106, Taiwan
[2] Stanford Univ, Dept Civil & Environm Engn, Stanford, CA 94305 USA
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 2004年 / 130卷 / 04期
关键词
damping; seismic response; field tests; earthquakes; viscoelasticity;
D O I
10.1061/(ASCE)0733-9445(2004)130:4(600)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the test and analytical results of a full-scale 5 story steel frame with added viscoelastic (VE) dampers. The ISD110 VE dampers made by 3M Company are installed to the long (East-West) direction of the structure. In addition to carrying out ambient and free vibration tests, the dynamic responses of the VE structure under four moderate earthquakes are recorded and analyzed. The ambient vibration tests show that the increase of damping in the full-scale structure is not obvious because of the small input energy. Nevertheless, in the free vibration tests and under earthquake ground motions, the increase of damping ratio is very significant. Analytical results show that when the structure is added with the diagonal-damper-brace assemblies, the modal strain energy method that has been validated by extensive shaking table tests on small-scale models slightly overestimates the damping ratio of the full-scale structure. However, when the structure is added with the floor-damper-brace assemblies, the method slightly underestimates the damping ratio. In addition to providing important database for verifying the effectiveness of applying the VE dampers to full-scale structures, this study also obtains important experiences concerning the implementation and detailed design of damper connections for practical applications.
引用
收藏
页码:600 / 608
页数:9
相关论文
共 50 条
  • [41] Earthquake response analyses of a full-scale five-story steel frame equipped with two types of dampers
    Yu, Yi-Jer
    Tsai, Keh-Chyuan
    Li, Chao-Hsien
    Weng, Yuan-Tao
    Tsai, Ching-Yi
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2013, 42 (09): : 1301 - 1320
  • [42] Dynamic Parameter Identification of Secondary Mass Dampers Based on Full-Scale Tests
    Cho, Bong-Ho
    Jo, Ji-Seong
    Joo, Seok-Jun
    Kim, Hongjin
    COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, 2012, 27 (03) : 218 - 230
  • [43] Full-scale experimental verification of resetable semi-active stiffness dampers
    Yang, J. N.
    Bobrow, J.
    Jabbari, F.
    Leavitt, J.
    Cheng, C. P.
    Lin, P. Y.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2007, 36 (09): : 1255 - 1273
  • [44] Full-scale test of dampers for stay cable vibration mitigation and improvement measures
    Zhou, Haijun
    Xiang, Ning
    Huang, Xigui
    Sun, Limin
    Xing, Feng
    Zhou, Rui
    STRUCTURAL MONITORING AND MAINTENANCE, 2018, 5 (04): : 489 - 506
  • [45] Damping of stay cable with passive-on magnetorheological dampers: a full-scale test
    Zhou, H. J.
    Sun, L. M.
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2013, 11 (3A) : 154 - 159
  • [46] Modeling seismic response of a full-scale cold-formed steel-framed building
    Leng, Jiazhen
    Peterman, Kara D.
    Bian, Guanbo
    Buonopane, Stephen G.
    Schafer, Benjamin W.
    ENGINEERING STRUCTURES, 2017, 153 : 146 - 165
  • [47] Experimental investigation on seismic performance of austenitic stainless steel full-scale frames: Component response
    Ning, Keyang
    Yang, Lu
    Jiang, Ke
    Han, Yawei
    ENGINEERING STRUCTURES, 2025, 326
  • [48] Bayesian seismic strong-motion response and damage estimation with application to a full-scale seven story shear wall structure
    Erao, Kalil
    Moaveni, Babak
    Nagarajaiah, Satish
    ENGINEERING STRUCTURES, 2019, 186 : 146 - 160
  • [49] Simulated seismic laboratory load testing of full-scale buildings
    Univ of California, San Diego, La Jolla, United States
    Earthquake Spectra, 1 (57-86):
  • [50] SEISMIC TESTING OF FULL-SCALE STEEL BUILDING .1.
    FOUTCH, DA
    GOEL, SC
    ROEDER, CW
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1987, 113 (11): : 2111 - 2129