Hemodynamic Comparison of Sutureless and Rapid-Deployment Valves with Conventional Bioprostheses

被引:9
作者
Gotzmann, Max [1 ]
Wilbring, Manuel [2 ]
Charitos, Efstratios [1 ]
Treede, Hendrik [1 ]
Silaschi, Miriam [1 ]
机构
[1] Midgerman Heart Ctr, Dept Cardiac Surg, Ernst Grube Str 40, D-06120 Halle, Saale, Germany
[2] Univ Heart Ctr Dresden, Dept Cardiac Surg, Dresden, Germany
关键词
aortic valve/root; heart valve surgery; cardiac; REPLACEMENT; PERFORMANCE; SOCIETY;
D O I
10.1055/s-0039-1683426
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Sutureless and rapid-deployment bioprostheses (RPDs) are advantageous due to shorter aortic cross-clamp times (ACCs); however, few studies have investigated hemodynamic outcomes in comparison to conventional bioprostheses (CBs). Methods All patients receiving the Perceval (LivaNova, London, United Kingdom) and Intuity (Edwards Lifesciences, Irvine, California, United States) valves from February 2016 to December 2017 were included (n = 61). For controls, patients who underwent aortic valve replacement using CB from 2015 to 2018 (n = 743) were propensity-matched (n = 108). Primary end points were mean gradient at discharge, true internal diameter (ID) after implantation, and paravalvular leakage. Secondary end points were ACCs, cardiopulmonary bypass times (CPBTs), mortality, and pacemaker implantation. Results Age was 73.2 years (standard deviation [SD]: 7.6) in the RPD group and 72.9 years (SD: 7.3) in the CB group (p = 0.827). Median logistic EuroSCORE II was 3.4% (Q1: 2; IQ3: 5.3) and 3% (Q1: 1.9; IQ3: 5.6; p = 0.599). While ACCs and CPBT were shorter in RPDs (97 [SD: 31.4] vs. 125.4 minutes [SD: 62.1], p = 0.003; and 76.1 [SD: 25.7] vs. 89.7 minutes [SD: 34.3], p = 0.022), procedural times were similar (p = 0.257). True ID was 21.97 mm (SD: 1.79) in RPDs and 20.15 mm (SD: 1.70) in CB (p < 0.001). RPDs and CB resulted in comparable mean gradients (12.8 mm Hg [SD: 6.4] vs. 13.8 mm Hg [SD: 5.6]; p = 0.387) and rate of paravalvular regurgitation. There were no differences in the rates of pacemaker implantation and mortality. In a subanalysis of RPDs, mean gradient was 15.48 mm Hg (SD: 7.51) in Perceval (n = 21) and 10.79 mm Hg (SD: 4.78) in Intuity (n = 33; p = 0.010). Conclusions RPDs provided comparable hemodynamic performance, although implanted valves were larger in true ID. Whether this provides superior hemodynamic performance during exercise and longer durability needs further investigation. Among RPDs, the Intuity valve provided lower mean gradients at rest than Perceval valve.
引用
收藏
页码:584 / 594
页数:11
相关论文
共 50 条
  • [1] Clinical and Hemodynamic Outcomes of Rapid-Deployment Aortic Bioprostheses
    D'Onofrio, Augusto
    Tessari, Chiara
    Cibin, Giorgia
    Lorenzoni, Giulia
    Martinelli, Gian Luca
    Solinas, Marco
    Gerosa, Gino
    Gregori, Dario
    Alamanni, Francesco
    Polvani, Gianluca
    Massetti, Massimo
    Di Eusanio, Marco
    Merlo, Maurizio
    Vendramin, Igor
    Mangino, Domenico
    Mignosa, Carmelo
    Russo, Claudio
    Rinaldi, Mauro
    De Paulis, Ruggero
    Pacini, Davide
    Luzi, Giampaolo
    Antona, Carlo
    Salvador, Loris
    Musumeci, Francesco
    Maselli, Daniele
    Colli, Andrea
    Portoghese, Michele
    Alfieri, Ottavio
    De Filippo, Carlo Maria
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2022, 34 (02) : 453 - 461
  • [2] Surgical aortic valve replacement with new-generation bioprostheses: Sutureless versus rapid-deployment
    D'Onofrio, Augusto
    Salizzoni, Stefano
    Filippini, Claudia
    Tessari, Chiara
    Bagozzi, Lorenzo
    Messina, Antonio
    Troise, Giovanni
    Dalla Tomba, Margerita
    Rambaldini, Manfredo
    Dalen, Magnus
    Alamanni, Francesco
    Massetti, Massimo
    Mignosa, Carmelo
    Russo, Claudio
    Salvador, Loris
    Di Bartolomeo, Roberto
    Maselli, Daniele
    De Paulis, Ruggero
    Alfieri, Ottavio
    De Filippo, Carlo Maria
    Portoghese, Michele
    Bortolotti, Uberto
    Rinaldi, Mauro
    Gerosa, Gino
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 159 (02) : 432 - +
  • [3] Are Sutureless and Rapid-Deployment Aortic Valves a Serious Alternative to TA-TAVI? A Matched-Pairs Analysis
    Al-Maisary, Sameer
    Farag, Mina
    Te Gussinklo, Willem Hendrik
    Kremer, Jamila
    Pleger, Sven T.
    Leuschner, Florian
    Karck, Matthias
    Szabo, Gabor
    Arif, Rawa
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (14)
  • [4] A Meta-Analysis of Sutureless or Rapid-Deployment Aortic Valve Replacement
    Takagi, Hisato
    Umemoto, Takuya
    THORACIC AND CARDIOVASCULAR SURGEON, 2016, 64 (05) : 400 - 409
  • [5] Conventional versus rapid-deployment aortic valve replacement: a single-centre comparison between the Edwards Magna valve and its rapid-deployment successor
    Andreas, Martin
    Wallner, Stephanie
    Habertheuer, Andreas
    Rath, Claus
    Schauperl, Martin
    Binder, Thomas
    Beitzke, Dietrich
    Rosenhek, Raphael
    Loewe, Christian
    Wiedemann, Dominik
    Kocher, Alfred
    Laufer, Guenther
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 22 (06) : 799 - 805
  • [6] Minimally invasive aortic valve replacement with sutureless and rapid deployment valves: a report from an international registry (Sutureless and Rapid Deployment International Registry)
    Berretta, Paolo
    Andreas, Martin
    Carrel, Thierry P.
    Solinas, Marco
    Teoh, Kevin
    Fischlein, Theodor
    Santarpino, Giuseppe
    Folliguet, Thierry
    Villa, Emmanuel
    Meuris, Bart
    Mignosa, Carmelo
    Martinelli, Gianluca
    Misfeld, Martin
    Glauber, Mattia
    Kappert, Utz
    Savini, Carlo
    Shrestha, Malak
    Phan, Kevin
    Albertini, Alberto
    Yan, Tristan
    Di Eusanio, Marco
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (04) : 793 - 799
  • [7] Rapid-deployment aortic valves: Do the data support a tipping point?
    Glotzbach, Jason P.
    McKellar, Stephen H.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 154 (05) : 1532 - 1533
  • [8] New cardiac bioprostheses: the case of 'sutureless' valves
    Albertini, Alberto
    Mikus, Elisa
    Sabarese, Marica
    Caprili, Luca
    Del Giglio, Mauro
    Lamarra, Mauro
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2015, 17 (0A) : A34 - A37
  • [9] Multicenter, propensity-weighted comparison of stented, rapid-deployment and new-generation aortic valves
    D'Onofrio, Augusto
    Cibin, Giorgia
    Tessari, Chiara
    Lorenzoni, Giulia
    Luzi, Giampaolo
    Manzan, Erica
    Gregori, Dario
    Gerosa, Gino
    IJC HEART & VASCULATURE, 2024, 54
  • [10] Current trends of sutureless and rapid deployment valves: an 11-year experience from the Sutureless and Rapid Deployment International Registry
    Berretta, Paolo
    Arzt, Sebastian
    Fiore, Antonio
    Carrel, Thierry P.
    Misfeld, Martin
    Teoh, Kevin
    Villa, Emmanuel
    Albertini, Alberto
    Fischlein, Theodor
    Martinelli, Gianluca
    Shrestha, Malak
    Savini, Carlo
    Miceli, Antonio
    Santarpino, Giuseppe
    Andreas, Martin
    Mignosa, Carmelo
    Phan, Kevin
    Meuris, Bart
    Solinas, Marco
    Yan, Tristan
    Di Eusanio, Marco
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 58 (05) : 1054 - 1062