Technical Note: MRI only prostate radiotherapy planning using the statistical decomposition algorithm

被引:108
作者
Siversson, Carl [1 ,2 ]
Nordstrom, Fredrik [2 ,3 ,4 ]
Nilsson, Terese [2 ]
Nyholm, Tufve [5 ]
Jonsson, Joakim [5 ]
Gunnlaugsson, Adalsteinn [6 ]
Olsson, Lars E. [1 ]
机构
[1] Lund Univ, Dept Med Radiat Phys, S-20502 Malmo, Sweden
[2] Spectron Med AB, S-25467 Helsingborg, Sweden
[3] Skane Univ Hosp, Dept Radiat Phys, S-21428 Lund, Sweden
[4] Lund Univ, Dept Med Radiat Phys, S-21428 Lund, Sweden
[5] Umea Univ, Dept Radiat Sci, S-90185 Umea, Sweden
[6] Lund Univ, Skane Univ Hosp, Dept Oncol, S-21428 Lund, Sweden
关键词
MRI; radiotherapy; treatment planning; dose calculation; synthetic CT; ELECTRON-DENSITY; IMAGES; SEGMENTATION; DISTORTION; PREDICTION;
D O I
10.1118/1.4931417
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In order to enable a magnetic resonance imaging (MRI) only workflow in radiotherapy treatment planning, methods are required for generating Hounsfield unit (HU) maps (i.e., synthetic computed tomography, sCT) for dose calculations, directly from MRI. The Statistical Decomposition Algorithm (SDA) is a method for automatically generating sCT images from a single MR image volume, based on automatic tissue classification in combination with a model trained using a multimodal template material. This study compares dose calculations between sCT generated by the SDA and conventional CT in the male pelvic region. Methods: The study comprised ten prostate cancer patients, for whom a 3D T2 weighted MRI and a conventional planning CT were acquired. For each patient, sCT images were generated from the acquired MRI using the SDA. In order to decouple the effect of variations in patient geometry between imaging modalities from the effect of uncertainties in the SDA, the conventional CT was nonrigidly registered to the MRI to assure that their geometries were well aligned. For each patient, a volumetric modulated arc therapy plan was created for the registered CT (rCT) and recalculated for both the sCT and the conventional CT. The results were evaluated using several methods, including mean average error (MAE), a set of dose-volume histogram parameters, and a restrictive gamma criterion (2% local dose/1 mm). Results: The MAE within the body contour was 36.5 +/- 4.1 (1 s.d.) HU between sCT and rCT. Average mean absorbed dose difference to target was 0.0% +/- 0.2% (1 s.d.) between sCT and rCT, whereas it was -0.3% +/- 0.3% (1 s.d.) between CT and rCT. The average gamma pass rate was 99.9% for sCT vs rCT, whereas it was 90.3% for CT vs rCT. Conclusions: The SDA enables a highly accurate MRI only workflow in prostate radiotherapy planning. The dosimetric uncertainties originating from the SDA appear negligible and are notably lower than the uncertainties introduced by variations in patient geometry between imaging sessions. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:6090 / 6097
页数:8
相关论文
共 29 条
[1]   Multi-atlas based segmentation of brain images: Atlas selection and its effect on accuracy [J].
Aljabar, P. ;
Heckemann, R. A. ;
Hammers, A. ;
Hajnal, J. V. ;
Rueckert, D. .
NEUROIMAGE, 2009, 46 (03) :726-738
[2]   Characterization, prediction, and correction of geometric distortion in 3 T MR images [J].
Baldwin, Lesley N. ;
Wachowicz, Keith ;
Thomas, Steven D. ;
Rivest, Ryan ;
Fallone, B. Gino .
MEDICAL PHYSICS, 2007, 34 (02) :388-399
[3]  
Bishop Christopher, 2006, Pattern Recognition and Machine Learning, DOI 10.1117/1.2819119
[4]   DOSIMETRIC PRECISION REQUIREMENTS IN RADIATION-THERAPY [J].
BRAHME, A .
ACTA RADIOLOGICA ONCOLOGY, 1984, 23 (05) :379-391
[5]   Attenuation Correction Synthesis for Hybrid PET-MR Scanners: Application to Brain Studies [J].
Burgos, Ninon ;
Cardoso, M. Jorge ;
Thielemans, Kris ;
Modat, Marc ;
Pedemonte, Stefano ;
Dickson, John ;
Barnes, Anna ;
Ahmed, Rebekah ;
Mahoney, Colin J. ;
Schott, Jonathan M. ;
Duncan, John S. ;
Atkinson, David ;
Arridge, Simon R. ;
Hutton, Brian F. ;
Ourselin, Sebastien .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (12) :2332-2341
[6]   The contribution of magnetic resonance imaging to the three-dimensional treatment planning of localized prostate cancer [J].
Debois, M ;
Oyen, R ;
Maes, F ;
Verswijvel, G ;
Gatti, G ;
Bosmans, H ;
Feron, M ;
Bellon, E ;
Kutcher, G ;
Van Poppel, H ;
Vanuytsel, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (04) :857-865
[7]   A complete distortion correction for MR images: I. Gradient warp correction [J].
Doran, SJ ;
Charles-Edwards, L ;
Reinsberg, SA ;
Leach, MO .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (07) :1343-1361
[8]   An Atlas-Based Electron Density Mapping Method for Magnetic Resonance Imaging (MRI)-Alone Treatment Planning and Adaptive MRI-Based Prostate Radiation Therapy [J].
Dowling, Jason A. ;
Lambert, Jonathan ;
Parker, Joel ;
Salvado, Olivier ;
Fripp, Jurgen ;
Capp, Anne ;
Wratten, Chris ;
Denham, James W. ;
Greer, Peter B. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (01) :E5-E11
[9]  
EDGEWORTH F., 1888, PHILOS MAG, V25, P184, DOI [DOI 10.1080/14786448808628170, 10.1080/14786448808628170]
[10]   NONSTANDARD DEVIATIONS [J].
GOITEIN, M .
MEDICAL PHYSICS, 1983, 10 (05) :709-711