Early Outcomes of Thoracic Endovascular Stent-Graft Repair for Acute Complicated Type B Dissection Using the Gore TAG Endoprosthesis

被引:34
作者
Pearce, Benjamin J. [1 ]
Passman, Marc A. [1 ]
Patterson, Mark A. [1 ]
Taylor, Steve M. [1 ]
Lecroy, Christopher J. [1 ]
Combs, Bart R. [1 ]
Jordan, William D. [1 ]
机构
[1] Univ Alabama Hosp & Clin, Sect Vasc Surg & Endovasc Therapy, Birmingham, AL 35294 USA
关键词
D O I
10.1016/j.avsg.2008.08.035
中图分类号
R61 [外科手术学];
学科分类号
摘要
We assessed the technical success and early outcome of thoracic endovascular aortic repair (TEVAR) for complicated acute type B thoracic aortic dissection treated at a single institution using a commercially available device. All patients with symptomatic complicated acute type B thoracic aortic dissection treated with TEVAR since Food and Drug Administration approval of the Gore (Flagstaff, AZ) TAG (R) endoprosthesis were identified from a prospectively maintained vascular registry. Clinical indications, operative technique, perioperative complications, follow-up imaging, and mortality were analyzed. Between March 2005 and November 2007, 127 TEVARs using the TAG endoprosthesis were performed, of which 15 (11.8%) were for complicated acute type B thoracic aortic dissection. Indications for repair were malperfusion (53%), persistent pain (27%), and primary aortic failure (33%). Technical feasibility and success with deployment proximal to the entry tear was 93.3%, requiring at least partial coverage of the left subclavian artery in seven (46.7%). Adjunctive procedures required at the time of TEVAR included renal stent (n = 2), iliac stent (n = 3), and access- artery open repair (n = 2). Twelve patients (80%) had immediate resolution of the malperfusion deficit. Major perioperative complications included paraplegia (13.3%), renal failure requiring hemodialysis (13.3%), and stroke (6.7%). Perioperative mortality was 13.3%, occurring in one patient presenting with rupture and one with profound heart failure on admission. For complicated acute type B thoracic aortic dissection, TEVAR using commercially available stent grafts showed high technical success, excellent results at resolving malperfusion, and acceptably low complications and perioperative mortality.
引用
收藏
页码:742 / 749
页数:8
相关论文
共 26 条
[1]   Effects of the patent false lumen on the long-term outcome Iq of type B acute aortic dissection [J].
Akutsu, K ;
Nejima, J ;
Kiuchi, K ;
Sasaki, K ;
Ochi, M ;
Tanaka, K ;
Takano, T .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (02) :359-366
[2]  
BRUNKWALL J, 2007, 29 CHAR CROSS INT S
[3]   Neurologic complications associated with endovascular repair of thoracic aortic pathology: Incidence and risk factors. A study from the European Collaborators on Stent/Graft Techniques for Aortic Aneurysm Repair (EUROSTAR) Registry [J].
Buth, Jacob ;
Harris, Peter L. ;
Hobo, Roel ;
van Eps, Randolph ;
Cuypers, Philippe ;
Duijm, Lucien ;
Tielbeek, Xander .
JOURNAL OF VASCULAR SURGERY, 2007, 46 (06) :1103-1111
[4]  
CAMBRIA R, 2005, RUTHERFORD VASCULAR, P1521
[5]   Spinal cord ischemia after elective stent-graft repair of the thoracic aorta [J].
Chiesa, R ;
Melissano, G ;
Marrocco-Trischitta, MM ;
Civilini, E ;
Setacci, F .
JOURNAL OF VASCULAR SURGERY, 2005, 42 (01) :11-17
[6]   Technical strategies to expand stent-graft applicability in the aortic arch and proximal descending thoracic aorta [J].
Criado, FJ ;
Barnatan, MF ;
Rizk, Y ;
Clark, NS ;
Wang, CF .
JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 :32-38
[7]   Treatment of type B aortic dissection: endoluminal repair or conventional medical therapy? [J].
Dialetto, G ;
Covino, FE ;
Scognamiglio, G ;
Manduca, S ;
Della Corte, A ;
Giannolo, B ;
Scardone, M ;
Cotrufo, M .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 27 (05) :826-830
[8]   Endovascular stent-graft placement in aortic dissection:: a meta-analysis [J].
Eggebrecht, H ;
Nienaber, CA ;
Neuhäuser, M ;
Baumgart, D ;
Kische, S ;
Schmermund, A ;
Herold, U ;
Rehders, TC ;
Jakob, HG ;
Erbel, R .
EUROPEAN HEART JOURNAL, 2006, 27 (04) :489-498
[9]  
Görich J, 2002, J ENDOVASC THER, V9, P39
[10]   Risk of spinal cord ischemia after endograft repair of thoracic aortic aneurysms [J].
Gravereaux, EC ;
Faries, PL ;
Burks, JA ;
Latessa, V ;
Spielvogel, D ;
Hollier, LH ;
Marin, ML .
JOURNAL OF VASCULAR SURGERY, 2001, 34 (06) :997-1001