Refrigerant migration during startup of a split air conditioner in heating mode

被引:22
作者
Han, Binglong [1 ]
Yan, Gang [1 ]
Yu, Jianlin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Shaanxi, Peoples R China
关键词
Refrigerant mass distribution; Supply air temperature; Heating capacity; Control method; Room air conditioner; INDOOR THERMAL COMFORT; COMPRESSOR; OPERATION; PRESSURE; SYSTEMS; R-410A; R290;
D O I
10.1016/j.applthermaleng.2018.11.126
中图分类号
O414.1 [热力学];
学科分类号
摘要
During winters, room air conditioners are generally expected to supply occupants with hot air rapidly following startup. In this study, the refrigerant migration characteristics during startup of a split air conditioner were experimentally investigated in heating mode. The transient refrigerant distribution inside main components was measured by using the quick-closing valve technique. The high and low side pressures and temperatures of the system were also investigated under the given operating conditions. All experiments were carried out in psychrometric rooms. On this basis, two control methods during the startup and shutdown process were proposed and tested. It was verified that increasing the refrigerant mass in the condenser prior to restarting can benefit the establishment of high pressure and supply occupants with air at a comfortable temperature more rapidly.
引用
收藏
页码:1068 / 1073
页数:6
相关论文
共 27 条
[1]   Energy saving and indoor thermal comfort evaluation using a novel local exhaust ventilation system for office rooms [J].
Ahmed, Ahmed Qasim ;
Gao, Shian ;
Kareem, Ali Khaleel .
APPLIED THERMAL ENGINEERING, 2017, 110 :821-834
[2]   Refrigerant mass charge distribution in a domestic refrigerator.: Part I:: Transient conditions [J].
Björk, E ;
Palm, B .
APPLIED THERMAL ENGINEERING, 2006, 26 (8-9) :829-837
[3]   A simple technique for refrigerant mass measurement [J].
Björk, E .
APPLIED THERMAL ENGINEERING, 2005, 25 (8-9) :1115-1125
[4]   Comparing different control strategies for indoor thermal comfort aimed at the evaluation of the energy cost of quality of building [J].
Calvino, Francesco ;
La Gennusa, Maria ;
Morale, Massimo ;
Rizzo, Gianfranco ;
Scaccianoce, Gianluca .
APPLIED THERMAL ENGINEERING, 2010, 30 (16) :2386-2395
[5]   Indoor thermal comfort characteristics under the control of a direct expansion air conditioning unit having a variable-speed compressor and a supply air fan [J].
Deng Shiming ;
Li Zheng ;
Qu Minglu .
APPLIED THERMAL ENGINEERING, 2009, 29 (11-12) :2187-2193
[6]  
Elbel, 2014, 15 INT REFR AIR COND
[7]   Alternative strategies for supply air temperature control in office buildings [J].
Gruber, Mattias ;
Truschel, Anders ;
Dalenback, Jan-Olof .
ENERGY AND BUILDINGS, 2014, 82 :406-415
[8]   Transient Characteristics of Split Air-Conditioning Systems Using R-22 and R-410A as Refrigerants [J].
Kapadia, R. G. ;
Jain, Sanjeev ;
Agarwal, R. S. .
HVAC&R RESEARCH, 2009, 15 (03) :617-649
[9]   Dynamic characteristics of a R-410A split air-conditioning system [J].
Kim, MH ;
Bullard, CW .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (07) :652-659
[10]  
Li, 2017, TRANSIENT DISTRIBUTI