A mid-IR flow-through sensor for direct monitoring of enzyme catalysed reactions. Case study: measurement of carbohydrates in beer

被引:20
作者
Haberkorn, M [1 ]
Hinsmann, P [1 ]
Lendl, B [1 ]
机构
[1] Vienna Univ Technol, Inst Analyt Chem, A-1060 Vienna, Austria
关键词
D O I
10.1039/b109594c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel mid-IR flow-through sensor for in situ monitoring of the enzymatic reaction of amyloglucosidase with carbohydrates was developed. Amyloglucosidase was immobilised on agarose beads with N-ethyl-N'-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC) and directly placed in a conventional IR flow-through cell. The carbohydrate content of various beer samples was then determined by following the enzymatic hydrolytic cleavage of carbohydrates to glucose with Fourier-transform infrared (FTIR) spectroscopy. The whole procedure was done in an automated way operating in the stopped flow mode by incorporating the flow-through sensor in a sequential injection (SI) manifold. As the immobilised enzyme was directly probed by the IR beam, an in situ study of the enzymatic reaction was possible enabling determination of the Michaelis-Menten constant of the immobilised enzyme. A linear calibration curve was recorded using maltose standards in the range between 0.86 and 7.13 g L-1. The proposed method was successfully applied to the determination of the carbohydrate content of four different beer samples by the standard addition method. Moreover experiments showed the possibility of monitoring in situ the immobilisation of the enzyme as well as a small organic acid (malic acid) on the agarose beads using EDC.
引用
收藏
页码:109 / 113
页数:5
相关论文
共 27 条
[1]  
[Anonymous], [No title captured]
[2]   QUANTITATIVE-ANALYSIS OF INDIVIDUAL SUGARS DURING STARCH HYDROLYSIS BY FT-IR/ATR SPECTROMETRY .1. MULTIVARIATE CALIBRATION STUDY - REPEATIBILITY AND REPRODUCIBILITY [J].
BELLONMAUREL, V ;
VALLAT, C ;
GOFFINET, D .
APPLIED SPECTROSCOPY, 1995, 49 (05) :556-562
[3]  
BERGMEYER HU, 1983, METHOD ENZYMAT AN, V1, P68
[4]   FLUOROMETRIC FLOW-THROUGH SENSOR FOR ALUMINUM SPECIATION [J].
CANIZARES, P ;
DECASTRO, MDL .
ANALYTICA CHIMICA ACTA, 1994, 295 (1-2) :59-65
[5]   FLOW-THROUGH FLUOROMETRIC SENSOR FOR THE DETERMINATION OF ALUMINUM AT THE NANOGRAM PER MILLILITER LEVEL [J].
CANIZARES, P ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL LETTERS, 1994, 27 (02) :247-262
[6]   FLOW-THROUGH SENSOR FOR THE DIRECT DETERMINATION OF PESTICIDE MIXTURES WITHOUT CHROMATOGRAPHIC-SEPARATION [J].
FERNANDEZBAND, B ;
LINARES, P ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1672-1675
[7]   FLOW-INJECTION DETERMINATION OF MIXTURES OF AMINES IMMOBILIZED IN THE FLOW CELL OF A PHOTOMETRIC DIODE-ARRAY DETECTOR [J].
FERNANDEZBAND, B ;
LAZARO, F ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1990, 229 (02) :177-182
[8]   FLOW-THROUGH OPTICAL BIOSENSOR BASED ON THE PERMANENT IMMOBILIZATION OF AN ENZYME AND TRANSIENT RETENTION OF A REACTION-PRODUCT [J].
FERNANDEZROMERO, JM ;
DECASTRO, MDL .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3048-3052
[9]  
GALLIGNANI M, 1994, ANAL CHIM ACTA, V29, P155
[10]   ENHANCEMENT OF FLOW-INJECTION OPTOSENSING BY SORBENT EXTRACTION AND REACTION-RATE MEASUREMENT [J].
LACY, N ;
CHRISTIAN, GD ;
RUZICKA, J .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1482-1490