Investigation of Aging Degradation Status of Insulating Elements in Oil-immersed Transformer and its Diagnostic Method Based on Field Measurement Data

被引:58
作者
Okabe, Shigemitsu [1 ]
Ueta, Genyo [1 ]
Tsuboi, Toshihiro [1 ]
机构
[1] Tokyo Elect Power Co Ltd, Tsurumi Ku, Yokohama, Kanagawa 2308510, Japan
关键词
Oil-immersed power transformer; aging; insulating oil; breakdown voltage; insulating paper; average polymerization degree (DP); oil components;
D O I
10.1109/TDEI.2013.6451376
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To ensure the reliability of oil-immersed power transformers in long-term operation, the influence of aging on various characteristics of their insulating elements must be clarified. The present paper reviewed the degradation status of insulating oil and paper of field-aged transformers, covering investigative results ranging from about 30 years ago to a relatively recent period. The field transformers treated were diverse in terms of their manufacturing year, manufacturer, structure, and voltage class. Despite the examination results of such wide-ranging transformers, there were similar changes in various characteristics due to the aging of insulating oil and paper. For example, as for the insulating oil, due to the aging for about 30 years, the characteristics of the total acid value and volume resistivity had degraded, whereas the breakdown voltage decreased only slightly. Regarding the insulating paper, mechanical characteristics such as the average polymerization degree (DP) were subject to age-related decline, whereas the breakdown voltage did not significantly decrease as with insulating oil. Therefore, based on use of about 30 years, since the life of a transformer is determined by factors such as the degradation of mechanical strength due to thermal stress, insulation degradation is considered less likely to pose a problem at an early stage. Even though it is difficult to directly measure the degree of degradation of insulating paper, this can be indirectly estimated by measuring the CO2 and CO content and furfural content in insulating oil. On the other hand, given the increasing number of transformers remaining in service over 30 years, which had been deemed the expected service life, consideration must be taken to aging degradation of the insulation performance. It emerged that, in order to identify the degree of degradation of these transformers, it was effective to manage the volume resistivity and dielectric loss tangent trends in electrical terms, the interfacial tension trend in physical terms and the total acid value trend in chemical terms. Analysis of the insulating oil components is also considered an effective means of evaluating aging degradation.
引用
收藏
页码:346 / 355
页数:10
相关论文
共 20 条
[1]  
[Anonymous], 1957, C571041991 IEEE
[2]  
[Anonymous], 1999, MAINT MAN OIL IMM TR, V54
[3]  
[Anonymous], 1995, 2200 JEC
[4]  
[Anonymous], 2006, C5712002006 IEEE
[5]  
[Anonymous], 2000, 600763 IEC
[6]  
Electric Technology Research Association of Japan, 2009, REPORT, V65
[7]  
Goodman E. A., 1971, ELECT LIGHT POWER, V62
[8]  
International Electrotechnical Commission, 2003, 602962013 IEC
[9]  
Ishii T, 2002, IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS, P1834, DOI 10.1109/TDC.2002.1177735
[10]  
Ishioka Y., 1984, IEEJ INSULATING MAT