Anterior Chamber Depth Measurement in Phakic and Pseudophakic Eyes

被引:43
|
作者
Su, Po-Fang [1 ]
Lo, Andy Y. [1 ]
Hu, Chao-Yu [1 ]
Chang, Shu-Wen [1 ,2 ]
机构
[1] Far Eastern Mem Hosp, Dept Ophthalmol, Taipei 220, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Ophthalmol, Taipei, Taiwan
关键词
anterior chamber depth; Pentacam; IOLMaster; A-scan ultrasonography; blue light-filtering IOLs;
D O I
10.1097/OPX.0b013e31818e8ceb
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare anterior chamber depth (ACD) measurements using two non-contact optical devices, Pentacam and IOLMaster, and a contact device, ultrasonic A-scan in phakic and pseudophakic eyes. Methods. Ninety phakic and 94 pseudophakic eyes were enrolled in this prospective Study. The difference between ACD measurements by the three devices was analyzed using the repeated-measures analysis of variance, and agreement among the three measurements was investigated. The accuracy of detecting the anterior lens surface of the intraocular lens (IOL) with or without blue-blocker was also assessed. Results. In phakic eyes, the Pentacam measured the deepest ACD with the smallest standard deviation (3.26 +/- 0.41, 3.20 +/- 0.45, and 3.12 +/- 0.44 mm measured by Pentacam, IOLMaster, and A-scan, respectively, p < 0.001). In contrast, the Pentacam measurement of ACD had the largest standard deviation in pseudophakic eyes (4.05 +/- 0.58, 4.06 +/- 0.46, and 3.81 +/- 0.41 mm by Pentacam, IOL-Master, and A-scan, respectively, p < 0.001). The Pentacam instrument failed to correctly identify the anterior lens surface in 26.4% of IOLs without blue-blocker and in 58.5% of blue light-filtering IOLs (p = 0.016). Manual correction of the Pentacam image and subsequent ACD measurement improved the agreement between Pentacam and the other two devices. After manual adjustment, the average ACD value increased, and the standard deviation decreased significantly (4.34 +/- 0.28 mm). Conclusions. ACD measurements by Pentacam, IOLMaster, and A-scan were in better agreement in phakic eyes when compared with pseudophakic eyes. In pseudophakic eyes, the 95% limits of agreements between Pentacam and IOLMaster as well as Pentacam and A-scan were unsatisfactory. IOLs with blue-blocker might interfere with ACD measurements. However, this error can be corrected manually in the Pentacam examination.
引用
收藏
页码:1193 / 1200
页数:8
相关论文
共 50 条
  • [31] Comparasion of Orbscan II Topography and Ultrasound Biometry in the Measurement of Anterior Chamber Depth
    Zengin, Ozgur
    Selver, Ozlem Barut
    Ozbek, Zeynep
    Yaman, Aylin
    Durak, Ismel
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2009, 39 (01): : 27 - 31
  • [32] Changes in the anterior and posterior radii of the corneal curvature and anterior chamber depth by orthokeratology
    Tsukiyama, Junko
    Miyamoto, Yuko
    Higaki, Shiro
    Fukuda, Masahiko
    Shimomura, Yoshikazu
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (01): : 17 - 20
  • [33] Changes of ocular biometry in eyes with posterior chamber phakic intraocular lens implantation
    Kayhan, B.
    Coskunseven, E.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2022, 45 (04): : 377 - 383
  • [34] Comparison of anterior chamber depth between normal and keratoconic eyes: A systematic review and meta-analysis
    Hashemi, Hassan
    Yekta, AbbasAli
    Yazdani, Negareh
    Ostadimoghaddam, Hadi
    Khabazkhoob, Mehdi
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2020, 32 (01): : 94 - 98
  • [35] Intraocular lens calculation formula selection for short eyes: based on axial length and anterior chamber depth
    Gao, Ruoxi
    Zhang, Jiaqing
    Han, Xiaotong
    Huang, Yiguo
    Huang, Ruoxuan
    Ye, Jinfeng
    Wen, Ling
    Qiu, Xiaozhang
    Chen, Xiaoyun
    Tan, Xuhua
    Luo, Lixia
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [36] Effect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with Cataract
    Gonen, Tansu
    Keskinbora, Kadircan
    Horozoglu, Fatih
    Sever, Ozkan
    Yasar, Mustafa
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (04): : 207 - 212
  • [37] Comparison of Corneal Diameter and Anterior Chamber Depth Measurements Using 4 Different Devices
    Shajari, Mehdi
    Lehmann, Ulrike C.
    Kohnen, Thomas
    CORNEA, 2016, 35 (06) : 838 - 842
  • [38] Anterior chamber depth in normal subjects by rotating scheimpflug imaging
    Feng, Matthew T.
    Belin, Michael W.
    Ambrosio, Renato, Jr.
    Grewal, Satinder P. S.
    Yan, Wang
    Shaheen, Mohamed S.
    McGhee, Charles
    Maeda, Naoyuki
    Neuhann, Tobias H.
    Dick, H. Burkhard
    Alageel, Saleh A.
    Steinmueller, Andreas
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2011, 25 (03) : 255 - 259
  • [39] Vault Height Is a Key Predictive Factor for Anterior Segment Measurement Error by IOLMaster 700 in Eyes With Phakic Intraocular Lens
    Zhang, Jiaqing
    Chen, Fei
    Han, Xiaotong
    Qiu, Xiaozhang
    Liu, Zhenzhen
    Chen, Xiaoyun
    Jin, Guangming
    Qu, Bo
    Yao, Huan
    Ye, Yiming
    Yu, Keming
    Tan, Xuhua
    Luo, Lixia
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2023, 12 (09):
  • [40] Measurement and prediction of the postoperative anterior chamber depth for intraocular lenses of different shape and material
    Haigis, W
    Kammann, J
    Dornbach, G
    Schuttrumpf, R
    ULTRASONOGRAPHY IN OPHTHALMOLOGY XV, 1997, 61 : 437 - 447