Anterior Chamber Depth Measurement in Phakic and Pseudophakic Eyes

被引:43
|
作者
Su, Po-Fang [1 ]
Lo, Andy Y. [1 ]
Hu, Chao-Yu [1 ]
Chang, Shu-Wen [1 ,2 ]
机构
[1] Far Eastern Mem Hosp, Dept Ophthalmol, Taipei 220, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Ophthalmol, Taipei, Taiwan
关键词
anterior chamber depth; Pentacam; IOLMaster; A-scan ultrasonography; blue light-filtering IOLs;
D O I
10.1097/OPX.0b013e31818e8ceb
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare anterior chamber depth (ACD) measurements using two non-contact optical devices, Pentacam and IOLMaster, and a contact device, ultrasonic A-scan in phakic and pseudophakic eyes. Methods. Ninety phakic and 94 pseudophakic eyes were enrolled in this prospective Study. The difference between ACD measurements by the three devices was analyzed using the repeated-measures analysis of variance, and agreement among the three measurements was investigated. The accuracy of detecting the anterior lens surface of the intraocular lens (IOL) with or without blue-blocker was also assessed. Results. In phakic eyes, the Pentacam measured the deepest ACD with the smallest standard deviation (3.26 +/- 0.41, 3.20 +/- 0.45, and 3.12 +/- 0.44 mm measured by Pentacam, IOLMaster, and A-scan, respectively, p < 0.001). In contrast, the Pentacam measurement of ACD had the largest standard deviation in pseudophakic eyes (4.05 +/- 0.58, 4.06 +/- 0.46, and 3.81 +/- 0.41 mm by Pentacam, IOL-Master, and A-scan, respectively, p < 0.001). The Pentacam instrument failed to correctly identify the anterior lens surface in 26.4% of IOLs without blue-blocker and in 58.5% of blue light-filtering IOLs (p = 0.016). Manual correction of the Pentacam image and subsequent ACD measurement improved the agreement between Pentacam and the other two devices. After manual adjustment, the average ACD value increased, and the standard deviation decreased significantly (4.34 +/- 0.28 mm). Conclusions. ACD measurements by Pentacam, IOLMaster, and A-scan were in better agreement in phakic eyes when compared with pseudophakic eyes. In pseudophakic eyes, the 95% limits of agreements between Pentacam and IOLMaster as well as Pentacam and A-scan were unsatisfactory. IOLs with blue-blocker might interfere with ACD measurements. However, this error can be corrected manually in the Pentacam examination.
引用
收藏
页码:1193 / 1200
页数:8
相关论文
共 50 条
  • [21] REFRACTION AND ANTERIOR-CHAMBER DEPTH BEFORE AND AFTER NEODYMIUM-YAG LASER TREATMENT FOR POSTERIOR CAPSULE OPACIFICATION IN PSEUDOPHAKIC EYES - A PROSPECTIVE-STUDY
    THORNVAL, P
    NAESER, K
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (04): : 457 - 460
  • [22] Comparison of anterior chamber depth measured by three different anterior segment analysis systems
    Song, Han
    Yang, Wei
    Yang, Chunliu
    Sun, Qing
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2025, 51
  • [23] Effects of Postural Variation on Anterior Chamber Depth in Pseudoexfoliative Eyes with Normal Intraocular Pressure
    Ermis, Sitki Samet
    CURRENT EYE RESEARCH, 2010, 35 (10) : 888 - 891
  • [24] Comparison of IOL master and ultrasound biomicroscopy in anterior chamber depth measurement
    Zhou, Wen-Kai
    Li, Xiao-Yan
    Zhang, Jin-Song
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2009, 2 (04): : 352 - 354
  • [25] The distribution of anterior chamber depth in a Tehran population: the Tehran eye study
    Hashemi, Hassan
    KhabazKhoob, Mehdi
    Mehravaran, Shiva
    Yazdani, Kamran
    Mohammad, Kazem
    Fotouhi, Akbar
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2009, 29 (04) : 436 - 442
  • [26] The measurement of anterior chamber depth and axial length with the IOLMaster compared with contact ultrasonic axial scan
    Bai, Quan-Hao
    Wang, Jun-Li
    Wang, Qing-Qiang
    Yan, Qi-Chang
    Zhang, Jin-Song
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2008, 1 (02) : 151 - 154
  • [27] Horizontal and anterior chamber diameter for phakic intraocular lens sizing
    Oleszko, Adam A.
    Marek, Jaroslaw J.
    Muzyka-Wozniak, Maria M.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2021, 104 (01) : 62 - 68
  • [28] Agreement of Corneal Diameter and Anterior Chamber Depth Measurements with the IOLMaster 500 and the IOLMaster 700 Optical Biometers in Myopic Eyes
    Tana-Rivero, Pedro
    Tello-Elordi, Cristina
    Orts-Vila, Paz
    Tana-Sanz, Pedro
    Tana-Sanz, Santiago
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 1245 - 1253
  • [29] Prediction of anterior chamber volume after implantation of posterior chamber phakic intraocular lens
    Takagi, Yuki
    Kojima, Takashi
    Nishida, Tomoya
    Nakamura, Tomoaki
    Ichikawa, Kazuo
    PLOS ONE, 2020, 15 (11):
  • [30] Agreement on Anterior Chamber Depth Measurement between Three Commercially Available Devices
    Noya-Padin, Veronica
    Pena-Verdeal, Hugo
    Garcia-Queiruga, Jacobo
    Sampedro-Marino, Irene
    Giraldez, Maria Jesus
    Yebra-Pimentel, Eva
    PHOTONICS, 2024, 11 (04)