Structural Performance of T-Stub End Plate Joints to Thin Walled Concrete Filled Steel Tube Columns

被引:0
|
作者
Azmi, Narul A. Z. [1 ]
Clotilda, P.
Hanizah, A. H. [2 ]
Azmi, I [1 ]
机构
[1] Univ Teknol MARA, Fac Civil Engn, Shah Alam, Selangor DE, Malaysia
[2] Univ Teknol MARA, Fac Civil Engn, Permatang Pauh, Pulau Pinang, Malaysia
关键词
EXPERIMENTAL BEHAVIOR; TUBULAR COLUMNS; CONNECTIONS;
D O I
10.1063/1.4965076
中图分类号
O59 [应用物理学];
学科分类号
摘要
Available literature has indicated that a thin-walled concrete filled steel tube (CFST) contributes to an ideal moment resisting capacity at the web-plate connection when the bolting type design is applied. In this research program, a combination of analytical and experimental studies was conducted to comprehend the behaviour of CFST attached with web-plate connection toward tensile resistance when the end-plate thickness and bolt arrangement changed. Four specimens had been tested using pull-out test. Each specimen consisted of a CFST column with a thin steel tube thickness of 2mm and attached to a T-stub type of connection. All columns and connections are fastened by M20 grade 8.8 with 110mm and 150mm longitudinal spacing between bolts whereas the thicknesses of T-stub end plate are 10mm and 12mm thick end-plate. The monotonic pull-out loading test was used until the specimens reached failure. Based on test results, the ultimate load for all specimens shows a similar behaviour with the Eurocode 3 standard. It can be concluded that the thin-walled CFST column is shown to be reliable to be used for tensile resisting composite frame structures especially for medium to high rise structures.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Structural performance of blind bolted end plate joints to concrete-filled thin-walled steel tubular columns
    Wang, Jingfeng
    Guo, Shuiping
    THIN-WALLED STRUCTURES, 2012, 60 : 54 - 68
  • [2] Tensile behavior of high performance structural steel T-stub joints
    Zhao, M. S.
    Lee, C. K.
    Chiew, S. P.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 122 : 316 - 325
  • [3] Strength and ductility of stiffened thin-walled hollow steel structural stub columns filled with concrete
    Tao, Zhong
    Han, Lin-Hai
    Wang, Dong-Ye
    THIN-WALLED STRUCTURES, 2008, 46 (10) : 1113 - 1128
  • [4] Calculation on stiffened concrete-filled thin-walled hollow steel structural (HSS) stub columns
    Wang, Zhi-Bin
    Duan, Hua-Fei
    Tao, Zhong
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 1443 - 1447
  • [5] Behavior of circular thin-walled steel tube confined concrete stub columns
    Ding, Fa-xing
    Tan, Liu
    Liu, Xue-mei
    Wang, Liping
    STEEL AND COMPOSITE STRUCTURES, 2017, 23 (02): : 229 - 238
  • [6] Study on stainless steel blind bolted T-stub to concrete-filled stainless steel tube connections
    Li, Ying-Lei
    Zhao, Xiao-Ling
    ENGINEERING STRUCTURES, 2022, 257
  • [7] Behavior of Corroded Thin-Walled Concrete-Filled Steel Tubular Stub Columns
    Xue, Wen
    Chen, Ju
    Xie, Fang
    Ye, Changhu
    Liu, Chengbin
    BUILDINGS, 2022, 12 (04)
  • [8] Experimental behaviour of stiffened concrete-filled thin-walled hollow steel structural (HSS) stub columns
    Tao, Z
    Han, LH
    Wang, ZB
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2005, 61 (07) : 962 - 983
  • [9] Assessment on seismic performance of circular concrete-filled thin-walled steel tube columns
    Wang, Xuanding
    Gao, Pan
    Liu, Jiepeng
    Zhao, Qiaorong
    Xu, Huimin
    Wei, Wei
    Wang, Xian-Tie
    ADVANCES IN STRUCTURAL ENGINEERING, 2023, 26 (03) : 399 - 412
  • [10] Axial behaviour of concrete filled steel tube stub columns: a review
    Guler, S.
    Korkut, F.
    Yaltay, N.
    Yavuz, D.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 359 - 363