Heart rate variability in severe aortic stenosis

被引:0
作者
Vukasovic, JL
Florenzano, F
Adriazola, P
Escobar, E
机构
[1] Univ Chile, Hosp Salvador, Santiago, Chile
[2] Hosp Direcc Previs Carabineros Chile, Santiago, Chile
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: Autonomic dysfunction may be a risk factor for the generation of arrhythmias and sudden death in patients with severe aortic stenosis; thus, patients with this condition were studied to assess cardiac autonomic function. Methods: Twelve patients (five males, seven females; mean age 63 +/- 13 years) with severe symptomatic aortic stenosis before and after aortic valve replacement, were compared with a control group matched by age and sex. In the study group, mean fractional shortening was 36.5 +/- 5% and maximal aortic gradient 94.7 +/- 12 mmHg, assessed echocardiographically. Autonomic dysfunction was evaluated by following heart rate variability in both time and frequency domains. Spectral analysis was assessed at very low frequency (VLF: 0.017-0.05 Hz), low frequency (LF: 0.05-0.15 Hz) and high frequency (HF: 0.15-0.50 Hz). Heart rate variability was analyzed during three intervals, between 6:00-8:00 am (morning), 14:00-16:00 (afternoon) and 02:00-04:00 (night), and re-evaluated at 8-10 months after aortic valve replacement. Results: Compared with controls, patients with aortic stenosis presented a significantly lower heart rate variability in the morning and afternoon, analyzed either by time or frequency domain: 50 +/- 22 versus 132 +/- 52 ms (p < 0.05); VLF 5.0 +/- 1.5 versus 7.9 +/- 1.4 ln (ms)(2) (p < 0.05); LF 4.9 +/- 1.7 versus 7.5 +/- 1.8 ln (ms)(2) (p < 0.05); HF 5.3 +/- 1.4 versus 7.5 +/- 1.8 ln (ms)(2) (p < 0.05). Results at night showed a similar tendency, but were not statistically significantly different. At 8-10 months after aortic valve replacement, heart rate variability was increased significantly during the morning, from 50 +/- 22 to 79.5 +/- 22 ms (p <0.05); VLF from 5.0 +/- 1.5 to 6.7 +/- 0.8 ln (ms)(2) (p < 0.05); LF from 4.9 +/- 1.7 to 6.2 +/- 1.3 ln (ms)(2) (p < 0.05). HF values tended to increase, though not significantly so. During the remainder of the day there was also a non-statistically significant increment in all values of heart rate variability. Conclusions: The study results suggest that patients with severe symptomatic aortic stenosis present with autonomic dysfunction that tends to normalize within the first year of valve replacement.
引用
收藏
页码:143 / 148
页数:6
相关论文
共 25 条
[21]   HEART-RATE-VARIABILITY - A MEASURE OF CARDIAC AUTONOMIC TONE [J].
STEIN, PK ;
BOSNER, MS ;
KLEIGER, RE ;
CONGER, BM .
AMERICAN HEART JOURNAL, 1994, 127 (05) :1376-1381
[22]   Impact of reduced heart rate variability on risk for cardiac events - The Framingham Heart Study [J].
Tsuji, H ;
Larson, MG ;
Venditti, FJ ;
Manders, ES ;
Evans, JC ;
Feldman, CL ;
Levy, D .
CIRCULATION, 1996, 94 (11) :2850-2855
[23]   REDUCED HEART-RATE-VARIABILITY AND MORTALITY RISK IN AN ELDERLY COHORT - THE FRAMINGHAM HEART-STUDY [J].
TSUJI, H ;
VENDITTI, FJ ;
MANDERS, ES ;
EVANS, JC ;
LARSON, MG ;
FELDMAN, CL ;
LEVY, D .
CIRCULATION, 1994, 90 (02) :878-883
[24]   Heart-Rate-Variability [J].
Vanravenswaaijarts, CMA ;
Kollee, LAA ;
Hopman, JCW ;
Stoelinga, GBA ;
Vangeijn, HP .
ANNALS OF INTERNAL MEDICINE, 1993, 118 (06) :436-447
[25]   NORMALIZATION OF DIASTOLIC DYSFUNCTION IN AORTIC-STENOSIS LATE AFTER VALVE-REPLACEMENT [J].
VILLARI, B ;
VASSALLI, G ;
MONRAD, ES ;
CHIARIELLO, M ;
TURINA, M ;
HESS, OM .
CIRCULATION, 1995, 91 (09) :2353-2358