Biomechanical Analysis of Hip Replacement Stem Design: A Finite Element Analysis

被引:1
作者
Azbari, Zahra Shamsipour [1 ]
Rad, Mohadese Rajaei [2 ]
Nahvinejad, Amirreza [1 ]
Gilakjani, Hasan Asadi [1 ]
Khorsandi, Mohammad [1 ]
机构
[1] Guilan Univ, Mech Engn Dept, Rasht, Iran
[2] Univ Tehran, Sch Mech Engn, Tehran, Iran
来源
2022 29TH NATIONAL AND 7TH INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING, ICBME | 2022年
关键词
Hip; Arthroplasty; Stem; finite element; geometry; STRAIN DISTRIBUTION; KNEE REPLACEMENT;
D O I
10.1109/ICBME57741.2022.10052890
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The hip joint is one of the largest joints of the body, which plays an important role in bearing the body's weight. When arthritis progresses to its higher levels, arthroplasty is performed to reduce pain and increase joint range of motion. This surgery is a common treatment worldwide, the quality of which depends on several factors. One of the critical factors is the geometry of the stem, which is implanted into the femur bone and receives support from it. For this aim, in this study, the geometry of three available stems in the orthopedic devices market was investigated by the finite element method (FEM). An accurate model of the proximal part of the femur was generated, and after modeling each stem, the final model was assembled. After developing the FE model, three loading conditions were applied to the stems. Maximum values of stress were observed in the middle part and neck of the stem. Moreover, it was observed that thickness is a key parameter in addition to the offset and neck shaft angle parameters and their effect on the amount and distribution of stress in the implant and bone. The results of this study can help improve the design of hip joint stems.
引用
收藏
页码:305 / 309
页数:5
相关论文
共 21 条
  • [1] Abdullah AH., 2017, Journal of Engineering and Applied Sciences, V12, P2715
  • [2] [Anonymous], Dataset
  • [3] Ashtiani Mohammad N., 2021, DYNAMIC STRESS STRAI, V19, P136
  • [4] HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS
    BERGMANN, G
    GRAICHEN, F
    ROHLMANN, A
    [J]. JOURNAL OF BIOMECHANICS, 1993, 26 (08) : 969 - 990
  • [5] Prediction of the strength and fracture location of the femoral neck by CT-based finite-element method: a preliminary study on patients with hip fracture
    Bessho, M
    Ohnishi, I
    Okazaki, H
    Sato, W
    Kominami, H
    Matsunaga, S
    Nakamura, K
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2004, 9 (06) : 545 - 550
  • [6] Primary stability and strain distribution of cementless hip stems as a function of implant design
    Bieger, Ralf
    Ignatius, Anita
    Decking, Ralf
    Claes, Lutz
    Reichel, Heiko
    Duerselen, Lutz
    [J]. CLINICAL BIOMECHANICS, 2012, 27 (02) : 158 - 164
  • [7] Brauer Carmen A., 1996, MEDICAL ENG PHYS, V18, P70
  • [8] Static structural analysis of different stem designs used in total hip arthroplasty using finite element method
    Chethan, K. N.
    Zuber, Mohammad
    Bhat, Shyamasunder N.
    Shenoy, Satish B.
    Kini, Chandrakant R.
    [J]. HELIYON, 2019, 5 (06)
  • [9] Temporal trends in hip and knee replacement in the United Kingdom 1991 TO 2006
    Culliford, D. J.
    Maskell, J.
    Beard, D. J.
    Murray, D. W.
    Price, A. J.
    Arden, N. K.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (01): : 130 - 135
  • [10] Changes in strain distribution of loaded proximal femora caused by different types of cementless femoral stems
    Decking, Ralf
    Puhl, Wolfhart
    Simon, Ulrich
    Claes, Lutz E.
    [J]. CLINICAL BIOMECHANICS, 2006, 21 (05) : 495 - 501