Implementation of a volumetric modulated arc therapy treatment planning solution for kidney and adrenal stereotactic body radiation therapy

被引:5
|
作者
Sonier, Marcus [1 ]
Chu, William [1 ,2 ]
Lalani, Nafisha [1 ]
Erler, Darby [1 ]
Cheung, Patrick [1 ,2 ]
Korol, Renee [1 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Odette Canc Ctr, Toronto, ON, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
关键词
VMAT; SBRT; RCC; Oligometastases; Treatment planning; Motion management; RADIOTHERAPY; CT;
D O I
10.1016/j.meddos.2016.09.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To develop a volumetric modulated arc therapy (VMAT) treatment planning solution in the treatment of primary renal cell carcinoma and oligometastatic adrenal lesions with stereotactic body radiation therapy. Single-arc VMAT plans (n = 5) were compared with clinically delivered step-and-shoot intensity-modulated radiotherapy (IMRT) with planning target volume coverage normalized between techniques. Target volume conformity, organ-at-risk (OAR) dose, treatment time, and monitor units were compared. A VMAT planning solution, created from a combination of arc settings and optimization constraints, auto-generated treatment plans in a single optimization. The treatment planning solution was evaluated on 15 consecutive patients receiving kidney and adrenal stereotactic body radiation therapy. Treatment time was reduced from 13.0 +/- 2.6 to 4.0 +/- 0.9 minutes for IMRT and VMAT, respectively. The VMAT planning solution generated treatment plans with increased target homogeneity, improved 95% conformity index, and a reduced maximum point dose to nearby OARs but with increased intermediate dose to distant OARs. The conformity of the 95% isodose improved from 1.32 +/- 0.39 to 1.12 +/- 0.05 for IMRT and VMAT treatment plans, respectively. Evaluation of the planning solution showed clinically acceptable dose distributions for 13 of 15 cases with tight conformity of the prescription isodose to the planning target volume of 1.07 +/- 0.04, delivering minimal dose to OARs. The introduction of a stereotactic body radiation therapy VMAT treatment planning solution improves the efficiency of planning and delivery time, producing treatment plans of comparable or superior quality to IMRT in the case of primary renal cell carcinoma and oligometastatic adrenal lesions. (C) 2016 American Association of Medical Dosimetrists.
引用
收藏
页码:323 / 328
页数:6
相关论文
共 50 条
  • [1] Interplay effects in highly modulated stereotactic body radiation therapy lung cases treated with volumetric modulated arc therapy
    Fernandez, Desmond J.
    Sick, Justin T.
    Fontenot, Jonas D.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (11): : 58 - 69
  • [2] A Collimator Setting Optimization Algorithm for Dual-Arc Volumetric Modulated Arc Therapy in Pancreas Stereotactic Body Radiation Therapy
    Li, Xinyi
    Wu, Jackie
    Palta, Manisha
    Zhang, You
    Sheng, Yang
    Zhang, Jiahan
    Wang, Chunhao
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2019, 18
  • [3] Biological-based optimization and volumetric modulated arc therapy delivery for stereotactic body radiation therapy
    Diot, Quentin
    Kavanagh, Brian
    Timmerman, Robert
    Miften, Moyed
    MEDICAL PHYSICS, 2012, 39 (01) : 237 - 245
  • [4] A comparison of robustness of volumetric modulated arc therapy and dynamic conformal arc therapy for lung stereotactic body radiation therapy
    Teague, Kathlina M.
    Miller, Daniel C.
    Nyamwanda, Jacqueline A.
    Prichard, Hugh A.
    Kirk, Michael C.
    MEDICAL DOSIMETRY, 2022, 47 (01) : 110 - 110
  • [5] Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy
    Mallory, Matthew
    Pokhrel, Damodar
    Badkul, Rajeev
    Jiang, Hongyu
    Lominska, Christopher
    Wang, Fen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 54 - 61
  • [6] Dosimetric study for spine stereotactic body radiation therapy: magnetic resonance guided linear accelerator versus volumetric modulated arc therapy
    Yadav, Poonam
    Musunuru, Hima B.
    Witt, Jacob S.
    Bassetti, Michael
    Bayouth, John
    Baschnagel, Andrew M.
    RADIOLOGY AND ONCOLOGY, 2019, 53 (03) : 362 - 368
  • [7] Feasibility of stereotactic body radiation therapy with volumetric modulated arc therapy and high intensity photon beams for hepatocellular carcinoma patients
    Wang, Po-Ming
    Hsu, Wei-Chung
    Chung, Na-Na
    Chang, Feng-Ling
    Jang, Chin-Jyh
    Fogliata, Antonella
    Scorsetti, Marta
    Cozzi, Luca
    RADIATION ONCOLOGY, 2014, 9
  • [8] Treatment planning for volumetric modulated arc therapy
    Bedford, James L.
    MEDICAL PHYSICS, 2009, 36 (11) : 5128 - 5138
  • [9] Feasibility of Implementing Stereotactic Body Radiation Therapy Using a Non-Commercial Volumetric Modulated Arc Therapy Treatment Planning System for Early Stage Lung Cancer
    Song, Yulin
    Mueller, Boris
    Obcemea, Ceferino
    Mychalczak, Borys
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 409 - 412
  • [10] Comparison of volumetric-modulated arc therapy and dynamic conformal arc treatment planning for cranial stereotactic radiosurgery
    Molinier, Jessica
    Kerr, Christine
    Simeon, Sebastien
    Ailleres, Norbert
    Charissoux, Marie
    Azria, David
    Fenoglietto, Pascal
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 92 - 101