Isotachophoresis on a chip with indirect fluorescence detection as a field deployable system for analysis of carboxylic acids

被引:14
|
作者
Smejkal, Petr [1 ,2 ]
Breadmore, Michael C. [1 ,2 ]
Guijt, Rosanne M. [3 ]
Foret, Frantisek [4 ]
Bek, Fritz [5 ]
Macka, Mirek [1 ,2 ]
机构
[1] Univ Tasmania, Sch Chem, Hobart, Tas 7005, Australia
[2] Univ Tasmania, ACROSS, Hobart, Tas 7005, Australia
[3] Univ Tasmania, Sch Pharm, Hobart, Tas 7005, Australia
[4] Acad Sci Czech Republic, Inst Analyt Chem, Vvi, CS-61142 Brno, Czech Republic
[5] Agilent Technol, Waldbronn, Germany
基金
澳大利亚研究理事会;
关键词
Carboxylic acids; Fluorescence; Indirect detection; Isotachophoresis; Microfluidics; CAPILLARY ISOTACHOPHORESIS; RECENT PROGRESS; ZONE-ELECTROPHORESIS; PRECONCENTRATION; CE; ITP; SEPARATION;
D O I
10.1002/elps.201200141
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
ITP with indirect fluorescence detection (IFD) was introduced three decades ago. Despite this fact, the method has never become widely adopted. The main aim of this work was to utilize the ITPIFD for the separation of carboxylic acids by using a commercially available, portable, microfluidic chip electrophoresis system. On the 16.8-mm effective length separation channel, a maximum of eight carboxylic acids could be separated, with LOD values in a range from 0.12 to 0.4 mM. The commercial chips used for all experiments have multichannel structures important for analysis of more than one sample per a chip in case of standard use. This multichannel structure was used to investigate the possibility of multiple sample loading for ITP separation. Application of ITPIFD was investigated for analysis of benzoate in diet soft drinks and the results were in good agreement with results of a CE method.
引用
收藏
页码:3166 / 3172
页数:7
相关论文
共 50 条
  • [1] Separation of carboxylic acids in human serum by isotachophoresis using a commercial field-deployable analytical platform combined with in-house glass microfluidic chips
    Smejkal, Petr
    Breadmore, Michael C.
    Guijt, Rosanne M.
    Grym, Jakub
    Foret, Frantisek
    Bek, Fritz
    Macka, Mirek
    ANALYTICA CHIMICA ACTA, 2012, 755 : 115 - 120
  • [2] A cost-effective and field-deployable sensing system for chip-integrated detection of bacteria with the naked eye
    Shen, Ren
    Hui, Wenhao
    Wu, Wenguang
    Yang, Ning
    Lin, Xiaodong
    Mak, Pui-In
    Martins, Rui P.
    Liu, Aiqun
    Jia, Yanwei
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 410
  • [3] High-sensitive analysis of DNA fragments by capillary gel electrophoresis using transient isotachophoresis preconcentration and fluorescence detection
    Xu, Zhongqi
    Esumi, Toshiaki
    Ikuta, Natsuki
    Hirokawa, Takeshi
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (17) : 3602 - 3605
  • [4] New derivatization method for carboxylic acids in aqueous solution for analysis by capillary electrophoresis and laser-induced fluorescence detection
    Kibler, M
    Bächmann, K
    JOURNAL OF CHROMATOGRAPHY A, 1999, 836 (02) : 325 - 331
  • [5] Exploring chip-capillary electrophoresis-laser-induced fluorescence field-deployable platform flexibility: Separations of fluorescent dyes by chip-based non-aqueous capillary electrophoresis
    Nuchtavorn, Nantana
    Smejkal, Petr
    Breadmore, Michael C.
    Guijt, Rosanne M.
    Doble, Philip
    Bek, Fritz
    Foret, Frantisek
    Suntornsuk, Leena
    Macka, Mirek
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1286 : 216 - 221
  • [6] Analysis of Aliphatic Organic Acids in Commercial Fruit Juices by Capillary Electrophoresis with Indirect UV Detection: Application to Differentiation of Fruit Juices
    Navarro-Pascual-Ahuir, Maria
    Jesus Lerma-Garcia, Maria
    Simo-Alfonso, Ernesto F.
    Manuel Herrero-Martinez, Jose
    FOOD ANALYTICAL METHODS, 2017, 10 (12) : 3991 - 4002
  • [7] Multicolor-Assay-on-a-Chip Processed by Robotic Operation (MACpro) with Improved Diagnostic Accuracy for Field-Deployable Detection
    Liu, Binyao
    Cheng, Yixin
    Pan, Xiang
    Yang, Wen
    Li, Xiangpeng
    Wang, Lele
    Ye, Haihang
    Pan, Tingrui
    ANALYTICAL CHEMISTRY, 2024, 96 (17) : 6634 - 6642
  • [8] Optimization of laser induced fluorescence detection system for integrated capillary electrophoresis chip
    Li, Y
    Cen, ZF
    Bao, ZK
    Li, XT
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 2, 2002, : 643 - 647
  • [9] Integration of a fluorescence detection system and a laminate-based disposable microfluidic chip
    Irawan, R
    Chuan, TS
    Yaw, FC
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2005, 45 (05) : 456 - 460
  • [10] Capillary electrophoretic analysis of arsenic species with indirect laser induced fluorescence detection
    Zhang, PD
    Xu, GW
    Xiong, JH
    Zheng, YF
    Yang, Q
    Wei, FS
    JOURNAL OF SEPARATION SCIENCE, 2002, 25 (03) : 155 - 159