Continuously moving table 3D MRI with lateral frequency-encoding direction

被引:11
作者
Aldefeld, B [1 ]
Börnert, P [1 ]
Keupp, J [1 ]
机构
[1] Philips Res Labs, Sector Tech Syst, D-22335 Hamburg, Germany
关键词
continuously moving table MRI; whole-body imaging; 3D; motion; magnetization preparation;
D O I
10.1002/mrm.20876
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method is presented for 3D MRI in an extended field of view (FOV) based on continuous motion of the patient table and an efficient acquisition scheme. A gradient-echo MR pulse sequence is applied with lateral (left-right (UR)) frequency-encoding direction and slab selection along the direction of motion. Compensation for the table motion is achieved by a combination of slab tracking and data alignment in hybrid space. The method allows fast k-space coverage to be achieved, especially when a short sampling FOV is chosen along the direction of table motion, as is desirable for good image quality. The method can be incorporated into different acquisitions schemes, including segmented k-space scanning, which allows for contrast variation with the use of magnetization preparation. Head-to-toe images of volunteers were obtained with good quality using 3D spoiled gradient-echo sequences. As an example of magnetization-prepared imaging, fat/water separated images were acquired using chemical shift selective (CHESS) presaturation pulses.
引用
收藏
页码:1210 / 1216
页数:7
相关论文
共 18 条
[1]  
ALDEFELD B, 2004, P 12 ANN M ISMRM TOK, P102
[2]   Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: Feasibility study [J].
Barkhausen, J ;
Quick, HH ;
Lauenstein, T ;
Goyen, M ;
Ruehm, SG ;
Laub, G ;
Debatin, JF ;
Ladd, ME .
RADIOLOGY, 2001, 220 (01) :252-256
[3]  
BOJAHR O, 1996, P ISMRM 4 ANN M NEW, P1734
[4]  
DIETRICH O, 1999, P 7 ANN M ISMRM PHIL, P1653
[5]   Gadolinium-enhanced three-dimensional MR angiography of the entire aorta and iliac arteries with dynamic manual table translation [J].
Earls, JP ;
DeSena, S ;
Bluemke, DA .
RADIOLOGY, 1998, 209 (03) :844-849
[6]   Floating table isotropic projection (FLIPR) acquisition: A time-resolved 3D method for extended field-of-view MRI during continuous table motion [J].
Fain, SB ;
Browning, FJ ;
Polzin, JA ;
Du, J ;
Zhou, Y ;
Block, WF ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) :1093-1102
[7]   Peripheral vascular tree stenoses: Evaluation with moving-bed infusion-tracking MR angiography [J].
Ho, KYJAM ;
Leiner, T ;
de Haan, MW ;
Kessels, AGH ;
Kitslaar, PJEHM ;
van Engelshoven, JMA .
RADIOLOGY, 1998, 206 (03) :683-692
[8]   Total-body echo-planar MR imaging in the staging of breast cancer: Comparison with conventional methods - Early experience [J].
Horvath, LJ ;
Burtness, BA ;
McCarthy, S ;
Johnson, KM .
RADIOLOGY, 1999, 211 (01) :119-128
[9]   Continuously moving table MRI with SENSE: Application in peripheral contrast enhanced MR angiography [J].
Hu, HH ;
Madhuranthakam, AJ ;
Kruger, DG ;
Glockner, JF ;
Riederer, SJ .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (04) :1025-1031
[10]   Total-body MR imaging in as little as 18 seconds [J].
Johnson, KMR ;
Leavitt, GD ;
Kayser, HWM .
RADIOLOGY, 1997, 202 (01) :262-267