Percutaneous Left Atrial Appendage Closure for Stroke Prophylaxis in Patients With Atrial Fibrillation 2.3-Year Follow-up of the PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) Trial

被引:486
作者
Reddy, Vivek Y. [1 ,2 ,3 ]
Doshi, Shephal K. [2 ]
Sievert, Horst [4 ]
Buchbinder, Maurice [5 ]
Neuzil, Petr [3 ]
Huber, Kenneth [6 ]
Halperin, Jonathan L. [1 ]
Holmes, David [7 ]
机构
[1] Mt Sinai Sch Med, New York, NY 10029 USA
[2] St Johns Hlth Ctr, Santa Monica, CA USA
[3] Homolka Hosp, Prague, Czech Republic
[4] Cardiovasc Ctr Frankfurt, Frankfurt, Germany
[5] Fdn Cardiovasc Med, La Jolla, CA USA
[6] St Lukes Hosp, Kansas City, MO USA
[7] Mayo Clin, Rochester, MN USA
关键词
anticoagulation; atrial fibrillation; catheters; left atrial appendage; pericardial effusion; stroke prevention; warfarin; PREVENT STROKE; WARFARIN; THERAPY; EXPERIENCE; OCCLUSION;
D O I
10.1161/CIRCULATIONAHA.112.114389
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The multicenter PROTECT AF study (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) was conducted to determine whether percutaneous left atrial appendage closure with a filter device (Watchman) was noninferior to warfarin for stroke prevention in atrial fibrillation. Methods and Results-Patients (n=707) with nonvalvular atrial fibrillation and at least 1 risk factor (age >75 years, hypertension, heart failure, diabetes, or prior stroke/transient ischemic attack) were randomized to either the Watchman device (n=463) or continued warfarin (n=244) in a 2: 1 ratio. After device implantation, warfarin was continued for approximate to 45 days, followed by clopidogrel for 4.5 months and lifelong aspirin. Study discontinuation rates were 15.3% (71/463) and 22.5% (55/244) for the Watchman and warfarin groups, respectively. The time in therapeutic range for the warfarin group was 66%. The composite primary efficacy end point included stroke, systemic embolism, and cardiovascular death, and the primary analysis was by intention to treat. After 1588 patient-years of follow-up (mean 2.3 +/- 1.1 years), the primary efficacy event rates were 3.0% and 4.3% (percent per 100 patient-years) in the Watchman and warfarin groups, respectively (relative risk, 0.71; 95% confidence interval, 0.44%-1.30% per year), which met the criteria for noninferiority (probability of noninferiority >0.999). There were more primary safety events in the Watchman group (5.5% per year; 95% confidence interval, 4.2%-7.1% per year) than in the control group (3.6% per year; 95% confidence interval, 2.2%-5.3% per year; relative risk, 1.53; 95% confidence interval, 0.95-2.70). Conclusions-The "local" strategy of left atrial appendage closure is noninferior to "systemic" anticoagulation with warfarin. PROTECT AF has, for the first time, implicated the left atrial appendage in the pathogenesis of stroke in atrial fibrillation.
引用
收藏
页码:720 / 729
页数:10
相关论文
共 50 条
[41]   Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation [J].
Swaans, Martin J. ;
Alipour, Arash ;
Rensing, Benno J. W. M. ;
Post, Martijn C. ;
Boersma, Lucas V. A. .
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2013, (72) :e3818
[42]   Evidence-Based Percutaneous Closure of the Left Atrial Appendage in Patients with Atrial Fibrillation [J].
Leal, Slvio ;
Moreno, Raul ;
de Sousa Almeida, Manuel ;
Aniceto Silva, Jose ;
Lopez-Sendon, Jose L. .
CURRENT CARDIOLOGY REVIEWS, 2012, 8 (01) :37-42
[43]   Utilization of percutaneous left atrial appendage closure in patients with atrial fibrillation: an update on patient outcomes [J].
Kleinecke, Caroline ;
Gloekler, Steffen ;
Meier, Bernhard .
EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2020, 18 (08) :517-530
[44]   Transcatheter left atrial appendage closure for stroke prevention among atrial fibrillation patients [J].
Khattab, Ahmed A. ;
Meier, Bernhard .
EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2012, 10 (07) :819-821
[45]   Left Atrial Appendage Closure for Stroke Prevention in Atrial Fibrillation [J].
Erin A. Fender ;
Jawad G. Kiani ;
David R. Holmes .
Current Atherosclerosis Reports, 2016, 18
[46]   Stroke prevention in atrial fibrillation with left atrial appendage closure [J].
Zack, Chad J. ;
Fender, Erin A. ;
Holmes, David R., Jr. .
MINERVA MEDICA, 2017, 108 (03) :199-211
[47]   Left Atrial Appendage Closure in Patients With Intracranial Hemorrhage and Nonvalvular Atrial Fibrillation [J].
Ajmal, Muhammad ;
Naik, Hursh ;
Kocheril, Abraham .
JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2020, 29 (04)
[48]   Combined atrial fibrillation ablation and left atrial appendage closure: Watchman vs. LAmbre devices [J].
Ke, Jin-Yan ;
Jin, Lu-Shen ;
Lin, Yuan-Nan ;
Xu, Jing ;
Liu, Wei-Ke ;
Fu, Jia-Yang ;
Li, Ling ;
Chen, Yi-Lian ;
Qiu, Yi-Xuan ;
Li, Yue-Chun .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
[49]   Safety of Percutaneous Left Atrial Appendage Closure with the Amplatzer Cardiac Plug in Patients with Atrial Fibrillation and Contraindications to Anticoagulation [J].
Wiebe, Jens ;
Bertog, Stefan ;
Franke, Jennifer ;
Wettstein, Olga ;
Lehn, Katharina ;
Hofmann, Ilona ;
Vaskelyte, Laura ;
Sievert, Horst .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (05) :796-802
[50]   Percutaneous left atrial appendage closure for stroke prevention in patients with atrial fibrillation: an assessment of net clinical benefit [J].
Gangireddy, Sandeep R. ;
Halperin, Jonathan L. ;
Fuster, Valentin ;
Reddy, Vivek Y. .
EUROPEAN HEART JOURNAL, 2012, 33 (21) :2700-2708