Single-shot echo-planar imaging with Nyquist ghost compensation: Interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI)

被引:21
|
作者
Poser, Benedikt A. [1 ,2 ]
Barth, Markus [2 ,3 ]
Goa, Pal-Erik [4 ]
Deng, Weiran [1 ]
Stenger, V. Andrew [1 ]
机构
[1] Univ Hawaii, John A Burns Sch Med, Dept Med, Honolulu, HI 96822 USA
[2] Radboud Univ Nijmegen, Ctr Brain Cognit & Behav, Donders Inst, NL-6525 ED Nijmegen, Netherlands
[3] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Essen, Germany
[4] St Olavs Univ Hosp, Dept Med Imaging, Med Imaging Lab, Trondheim, Norway
关键词
EPI; BOLD; Nyquist ghost; N/2; ghost; parallel imaging; GRAPPA; dual echo; IDEA EPI; GEOMETRIC DISTORTION; REFERENCE-SCAN; BOLD-CONTRAST; SENSITIVITY; ARTIFACTS; RECONSTRUCTION; OPTIMIZATION; ACQUISITION;
D O I
10.1002/mrm.24222
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Echo planar imaging (EPI) is most commonly used for blood oxygen level-dependent fMRI, owing to its sensitivity and acquisition speed. A major problem with EPI is Nyquist (N/2) ghosting, most notably at high field. EPI data are acquired under an oscillating readout gradient and hence vulnerable to gradient imperfections such as eddy current delays and off-resonance effects, as these cause inconsistencies between odd and even k-space lines after time reversal. We propose a straightforward and pragmatic method herein termed interleaved dual echo with acceleration (IDEA) EPI: two k-spaces (echoes) are acquired under the positive and negative readout lobes, respectively, by performing phase encoding blips only before alternate readout gradients. From these two k-spaces, two almost entirely ghost free images per shot can be constructed, without need for phase correction. The doubled echo train length can be compensated by parallel imaging and/or partial Fourier acquisition. The two k-spaces can either be complex averaged during reconstruction, which results in near-perfect cancellation of residual phase errors, or reconstructed into separate images. We demonstrate the efficacy of IDEA EPI and show phantom and in vivo images at both 3 T and 7 T. Magn Reson Med, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:37 / 47
页数:11
相关论文
共 50 条
  • [1] Referenceless interleaved echo-planar imaging
    Reeder, SB
    Atalar, E
    Faranesh, AZ
    McVeigh, ER
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (01) : 87 - 94
  • [2] INTERLEAVED ASYMMETRIC ECHO-PLANAR IMAGING
    HENNEL, F
    NEDELEC, JF
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) : 520 - 524
  • [3] The effect of residual Nyquist ghost in quantitative echo-planar diffusion imaging
    Porter, DA
    Calamante, F
    Gadian, DG
    Connelly, A
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (02) : 385 - 392
  • [4] Performance of Single-Shot Echo-Planar Imaging in Diffusion Tensor Imaging in Rat Sciatic Nerve Compared With Readout-Segmented Echo-Planar Imaging
    Chen, Yueyao
    Pan, Zhongxian
    Meng, Fanqi
    Li, Zhujing
    Hu, Yuanming
    Yu, Xuewen
    Gao, Jinyun
    Guo, Yihao
    Lyu, Hanqing
    Lin, Xiaofeng
    FRONTIERS IN NEUROSCIENCE, 2022, 16
  • [5] Detection of Middle Ear Cholesteatoma by Diffusion-Weighted MR Imaging: Multishot Echo-Planar Imaging Compared with Single-Shot Echo-Planar Imaging
    Yamashita, K.
    Yoshiura, T.
    Hiwatashi, A.
    Kamano, H.
    Dashjamts, T.
    Shibata, S.
    Tamae, A.
    Honda, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (10) : 1915 - 1918
  • [6] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    An, He
    Ma, Xiaodong
    Pan, Ziyi
    Guo, Hua
    Lee, Elaine Yuen Phin
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 1876 - 1884
  • [7] Readout-segmented echo-planar imaging in the evaluation of sinonasal lesions: A comprehensive comparison of image quality in single-shot echo-planar imaging
    Zhao, Menglong
    Liu, Zhuang
    Sha, Yan
    Wang, Shenjiang
    Ye, Xinpei
    Pan, Yucheng
    Wang, Shaoyu
    MAGNETIC RESONANCE IMAGING, 2016, 34 (02) : 166 - 172
  • [8] Comparison of DWI Methods in the Pediatric Brain: PROPELLER Turbo Spin-Echo Imaging Versus Readout-Segmented Echo-Planar Imaging Versus Single-Shot Echo-Planar Imaging
    Kim, Tae-Hyung
    Baek, Moon-Young
    Park, Ji Eun
    Ryu, Young Jin
    Cheon, Jung-Eun
    Kim, In-One
    Choi, Young Hun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (06) : 1352 - 1358
  • [9] Quantification and reduction of ghosting artifacts in interleaved echo-planar imaging
    Reeder, SB
    Atalar, E
    Bolster, BD
    McVeigh, ER
    MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) : 429 - 439
  • [10] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    He An
    Xiaodong Ma
    Ziyi Pan
    Hua Guo
    Elaine Yuen Phin Lee