Dynamic Modeling and Control for SPMSMs With Internal Turn Short Fault

被引:108
作者
Jeong, Ilsu [1 ]
Hyon, Byong Jo [1 ]
Nam, Kwanghee [1 ]
机构
[1] Pohang Univ Sci & Technol, Dept Elect Engn, Pohang 790784, South Korea
关键词
Dual current controllers; fault tolerant; flux linkage; motor internal turn fault; negative sequence; permanent magnet synchronous motor (PMSM); positive sequence; INDUCTION MACHINES; STATOR WINDINGS; MOTORS; DIAGNOSIS; LOCATION;
D O I
10.1109/TPEL.2012.2222049
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A dynamic model for a faulted surface-mount permanent magnet synchronous motor (SPMSM) is derived using a deformed flux model. In reflecting the internal turn short into the dynamics, the variations in inductance and back EMF term were considered. Then, the faulted model was transformed into the two synchronous dq-models: one for the positive sequence and the other for the negative sequence. Also, a torque equation, which shows the relation between the ripple and the negative sequence current, is derived. The negative sequence current should be suppressed to eliminate the torque ripple. The dual current controller is utilized for this purpose: in the dual controller, the positive and negative sequences are controlled separately in their own synchronous frames. Notch filters are utilized in each synchronous frame to extract positive or negative sequence component. Experiments were performed with an SPMSM specially designed to make an internal turn short artificially. The experimental results coincide well with the corresponding simulation results, and exhibit a strength of the dual current controller in suppressing the negative sequence current.
引用
收藏
页码:3495 / 3508
页数:14
相关论文
共 33 条
[1]   THE CAUSES AND CONSEQUENCES OF PHASE UNBALANCE IN SINGLE-SIDED LINEAR INDUCTION-MOTORS [J].
ADAMIAK, K ;
ANANTHASIVAM, K ;
DAWSON, GE ;
EASTHAM, AR ;
GIERAS, JF .
IEEE TRANSACTIONS ON MAGNETICS, 1988, 24 (06) :3223-3233
[2]  
[Anonymous], 1985, Adaptive signal processing prentice-hall
[3]   ANFIS-based diagnosis and location of stator interturn faults in PM brushless dc motors [J].
Awadallah, MA ;
Morcos, MM .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (04) :795-796
[4]   A Cooperative Imbalance Compensation Method for Distributed-Generation Interface Converters [J].
Cheng, Po-Tai ;
Chen, Chien-An ;
Lee, Tung-Lin ;
Kuo, Shen-Yuan .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (02) :805-815
[5]  
Cruz SMA, 2000, IEEE IND APPLIC SOC, P395, DOI 10.1109/IAS.2000.881141
[6]   Operation of fault tolerant machines with winding failures [J].
Haylock, JA ;
Mecrow, BC ;
Jack, AG ;
Atkinson, DJ .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (04) :1490-1495
[7]   PMSM Control Based on Edge-Field Hall Sensor Signals Through ANF-PLL Processing [J].
Jung, Sung-Yoon ;
Nam, Kwanghee .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (11) :5121-5129
[8]   The Internal Fault Analysis of Brushless DC Motors Based on the Winding Function Theory [J].
Kim, Taehyung ;
Lee, Hyung-Woo ;
Kwak, Sangshin .
IEEE TRANSACTIONS ON MAGNETICS, 2009, 45 (05) :2090-2096
[9]  
Kyung-Tae Kim, 2011, 8th International Conference on Power Electronics - ECCE Asia, P2216
[10]   A robust, on-line turn-fault detection technique for induction machines based on monitoring the sequence component impedance matrix [J].
Lee, SB ;
Tallam, RM ;
Habetler, TG .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2003, 18 (03) :865-872