Combined Composite Scintillation Detector for Separate Measurements of Fast and Thermal Neutrons

被引:0
|
作者
Galunov, Nikolai Z. [1 ]
Grinyov, Boris V. [1 ]
Karavaeva, Natalya L. [1 ]
Martynenko, Eugenia V. [1 ]
Tarasenko, Oleg A. [1 ]
Gerasymov, Yaroslav V. [1 ]
Sidletskiy, Oleg Ts [1 ]
机构
[1] Natl Acad Sci Ukraine, Inst Scintillat Mat, UA-61001 Kharkov, Ukraine
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We propose and study a new composite scintillation detector. It is the combined detector for separate detection of fast neutrons and thermal neutrons in the presence of gamma background radiation. The combined detector consists of two scintillation parts. It is the organic composite scintillator that is made from stilbene crystalline grains (grains with sizes from 2.5 to 3.0 mm) those we introduce in organosilicone matrix. The second part of the detector is a thin inorganic composite detector of thermal neutrons that contains Ce:GPS (Ce-doped gadolinium pyrosilicate) crystalline grains those are in the matrix of the same type. To detect thermal neutrons with minimal gamma background the single-layer composite material was used (grains with sizes in the following ranges: from 0.06 to 0.1, from 0.1 to 0.3 and from 0.3 to 0.5 mm). For chosen values of the sizes of the grains the efficiency of detection of gamma radiations with energies lower than 150 keV is negligible. The comparison of the values of scintillation amplitudes in the range of thermal neutron detection and in the range of recoil proton spectrum shows that the signals from thermal and fast neutrons do not overlap. Therefore the analysis of these two spectra can be run separately in different energy windows. The combined composite detector has no technological limitations on area of it input window. It needs screening from gamma radiations of low energies (corresponding to 33 keV peak from Gd conversion electrons or corresponding to the total range of 33 keV and 77 keV peaks). With increase of a grain size the efficiency of thermal neutrons detection growths. On the other hand the detection of the signals not only in the range of 33 keV peak but in the range of 77 keV peak as well causes the increase of the thickness of gamma-shielding and use a witness detector.
引用
收藏
页码:1813 / 1818
页数:6
相关论文
共 50 条
  • [21] Detector for separate detection of neutrons and γ rays
    V. F. Teplykh
    E. V. Platygina
    G. A. Mikhal’chenko
    Atomic Energy, 2000, 88 : 155 - 157
  • [22] Detector for separate detection of neutrons and γ rays
    Teplykh, VF
    Platygina, EV
    Mikhal'chenko, GA
    ATOMIC ENERGY, 2000, 88 (02) : 155 - 157
  • [23] THE SOLID-STATE SCINTILLATION PSD JULIOS - A FAST AND HIGH-RESOLUTION DETECTOR SYSTEM FOR THERMAL-NEUTRONS
    JANSEN, E
    SCHAFER, W
    SZEPESVARY, A
    WILL, G
    KURZ, R
    PHYSICA B-CONDENSED MATTER, 1989, 156 : 584 - 587
  • [24] Real-Time, Digital Imaging of Fast Neutrons and γ Rays with a Single Fast Liquid Scintillation Detector
    Joyce, Malcolm J.
    Gamage, Kelum A. A.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 602 - 606
  • [25] A time-gating scintillation detector for the measurement of laser-induced fast neutrons
    Lee, Sungman
    Park, Sangsoon
    Yea, Kwon-hae
    Cha, Hyungki
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (06):
  • [26] USE OF LI6I(EU) AS A SCINTILLATION DETECTOR AND SPECTROMETER FOR FAST NEUTRONS
    MURRAY, RB
    NUCLEAR INSTRUMENTS & METHODS, 1958, 2 (03): : 237 - 248
  • [27] BD-9 INTEGRAL DISCRIMINATOR IN SCINTILLATION DETECTOR SCHEME OF FAST-NEUTRONS
    IVANOV, EA
    USATYUK, VV
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1973, (01): : 105 - 106
  • [28] A SCINTILLATION COUNTER FOR THERMAL NEUTRONS
    DRAPER, JE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1951, 22 (07): : 543 - 543
  • [29] A SCINTILLATION COUNTER FOR DETECTING FAST NEUTRONS
    HARDING, GN
    NATURE, 1951, 167 (4246) : 437 - 437
  • [30] A Scintillation Detector of Protons and Neutrons, Products of a ddReaction
    V. N. Kornilov
    V. V. Maximov
    Instruments and Experimental Techniques, 2001, 44 : 219 - 223