Conventional radiographs vs digitized radiographs:: image quality assessment

被引:20
作者
Parissis, N
Kondylidou-Sidira, A [1 ]
Tsirlis, A
Patias, P
机构
[1] Aristotle Univ Thessaloniki, Sch Dent, Dept Oral Surg, Thessaloniki 54124, Greece
[2] Aristotle Univ Thessaloniki, Dept Cadastre Photogrammetry & Cartog, Lab Photogrammetry & Remote Sensing, GR-54006 Thessaloniki, Greece
关键词
dental radiography; digital image; scanner; density; contrast; resolution;
D O I
10.1259/dmfr/99611204
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to compare image quality characteristics of conventional radiographs and their digital counterparts. Methods: 100 conventional radiographs (E-speed) were used for the evaluation of density and contrast. The radiographs were made using a range of exposures under standardized conditions and were compared with digital images that resulted from scanning the above radiographs with a commercially available scanner. Resolution was evaluated with an experiment using 50 film packets and a resolution target exposed with different exposure times, using both the original radiographs and their scanned equivalents. Results: The digitized radiographs appeared to be of higher density than the conventional ones. Moreover, they demonstrated a narrower density range. Resolution was similar for both types of images. Conclusions: Although there is an agreement with the literature that the digitized radiographs are of higher density, further investigation is required to detect the various factors that may have an effect on the quality of the digitized images.
引用
收藏
页码:353 / 356
页数:4
相关论文
共 18 条
[1]   Digitisation and display of intra-oral films [J].
Attaelmanan, A ;
Borg, E ;
Grondahl, HG .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (02) :97-102
[2]   DIGITIZING OF RADIOGRAPHS WITH A FLAT-BED SCANNER [J].
CHEN, SK ;
HOLLENDER, L .
JOURNAL OF DENTISTRY, 1995, 23 (04) :205-208
[3]   An evaluation of the signal and noise characteristics of four CCD-based film digitizers [J].
Hangiandreou, NJ ;
O'Connor, TJ ;
Felmlee, JP .
MEDICAL PHYSICS, 1998, 25 (10) :2020-2026
[4]   Scanning resolution and the detection of approximal caries [J].
Janhom, A ;
van Ginkel, FC ;
van Amerongen, JP ;
van der Stelt, PF .
DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (03) :166-171
[5]  
Kaplan I, 1990, Quintessence Int, V21, P737
[6]   Visually detectable resolution of intraoral dental films [J].
Künzel, A ;
Scherkowski, D ;
Willers, R ;
Becker, J .
DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (06) :385-389
[7]   Image processing and enhancement provided by commercial dental software programs [J].
Lehmann, TM ;
Troeltsch, E ;
Spitzer, K .
DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (04) :264-272
[8]   Performance of film, desktop monitor and laptop displays in caries detection [J].
Ludlow, JB ;
Abreu, M .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (01) :26-30
[9]  
PARISSIS N, 1997, BALKAN J STOM, V1, P98
[10]  
PARISSIS N, 1996, STOMA, V24, P185