Calibration graphs in isotope dilution mass spectrometry

被引:31
作者
Pagliano, Enea [1 ]
Mester, Zoltan [1 ]
Meija, Juris [1 ]
机构
[1] Natl Res Council Canada, Ottawa, ON K1A 0R6, Canada
关键词
Isotope dilution; Stable isotope labeled internal standards; Calibration graphs; Nonlinearity;
D O I
10.1016/j.aca.2015.09.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Isotope-based quantitation is routinely employed in chemical measurements. Whereas most analysts seek for methods with linear theoretical response functions, a unique feature that distinguishes isotope dilution from many other analytical methods is the inherent possibility for a nonlinear theoretical response curve. Most implementations of isotope dilution calibration today either eliminate the nonlinearity by employing internal standards with markedly different molecular weight or they employ empirical polynomial fits. Here we show that the exact curvature of any isotope dilution curve can be obtained from three-parameter rational function, y = f(q) = (a(0) + a(1)q)/(1 + a(2)q), known as the Pade[1,1] approximant. The use of this function allows eliminating an unnecessary source of error in isotope dilution analysis when faced with nonlinear calibration curves. In addition, fitting with Pade model can be done using linear least squares. Crown Copyright (C) 2015 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:63 / 67
页数:5
相关论文
共 18 条
[1]  
Alonso JIG., 2013, Isotope Dilution Mass Spectrometry
[2]   ANALYSIS OF LINEAR APPROACHES TO QUANTITATIVE STABLE ISOTOPE METHODOLOGY IN MASS-SPECTROMETRY [J].
BUSH, ED ;
TRAGER, WF .
BIOMEDICAL MASS SPECTROMETRY, 1981, 8 (05) :211-218
[3]   COMPARISON OF CALCULATION PROCEDURES FOR ISOTOPE-DILUTION DETERMINATIONS USING GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
COLBY, BN ;
MCCAMAN, MW .
BIOMEDICAL MASS SPECTROMETRY, 1979, 6 (06) :225-230
[4]  
Duncan M.W., 2006, PRINCIPLES QUANTITAT
[5]   STATISTICAL EVALUATION OF CALIBRATION CURVE NONLINEARITY IN ISOTOPE-DILUTION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
JONCKHEERE, JA ;
DELEENHEER, AP .
ANALYTICAL CHEMISTRY, 1983, 55 (01) :153-155
[6]  
Jozef B., 2001, MEAS SCI REV, V1, P63
[7]   GAS CHROMATOGRAPH MASS SPECTROMETER ACCELERATING VOLTAGE ALTERNATOR SYSTEM FOR MEASUREMENT OF STABLE ISOTOPE RATIOS IN ORGANIC-MOLECULES [J].
KLEIN, PD ;
EISLER, WJ ;
HAUMANN, JR .
ANALYTICAL CHEMISTRY, 1972, 44 (03) :490-&
[8]   Coordinate Swapping in Standard Addition Graphs for Analytical Chemistry: A Simplified Path for Uncertainty Calculation in Linear and Nonlinear Plots [J].
Meija, Juris ;
Pagliano, Enea ;
Mester, Zoltan .
ANALYTICAL CHEMISTRY, 2014, 86 (17) :8563-8567
[9]   DETERMINATION OF CLONAZEPAM AND ITS 7-AMINO METABOLITE IN PLASMA AND BLOOD BY GAS CHROMATOGRAPHY CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
MIN, BH ;
GARLAND, WA .
JOURNAL OF CHROMATOGRAPHY, 1977, 139 (01) :121-133
[10]   DETERMINATION OF CARBOXYLIC-ACIDS BY ISOTOPE-DILUTION GAS-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED-SPECTROSCOPY [J].
OLSON, ES ;
DIEHL, JW ;
FROEHLICH, ML .
ANALYTICAL CHEMISTRY, 1988, 60 (18) :1920-1924