Development of single crystal diamond neutron detectors and test at JET tokamak

被引:58
作者
Angelone, M. [1 ,2 ]
Lattanzi, D. [1 ]
Pillon, M. [1 ,2 ]
Marinelli, M. [2 ,3 ]
Milani, E. [2 ,3 ]
Tucciarone, A. [3 ]
Verona-Rinati, G. [2 ,3 ]
Popovichev, S. [2 ,4 ]
Montereali, R. M. [5 ]
Vincenti, M. A. [5 ]
Murari, A. [2 ,6 ]
机构
[1] ENEA Fusione, EURATOM Assoc, I-00044 Rome, Italy
[2] JET EFDA, Culham Sci Ctr, Abingdon OX14 3DB, Oxon, England
[3] Univ Roma Tor Vergata, Dipartimento Ingn Meccan, EURATOM Assoc, I-00133 Rome, Italy
[4] UKAEA Euratom Fus Assoc, Culham Sci Ctr, Abingdon OX14 3DB, Oxon, England
[5] ENEA, Phys Technol & New Mat Dept, I-00044 Rome, Italy
[6] ENEA Fusione, EURATOM Assoc, Consorzio RFX, I-35127 Padua, Italy
基金
英国工程与自然科学研究理事会;
关键词
CVD diamond neutron detectors; Fusion neutrons detection; Neutron diagnostics;
D O I
10.1016/j.nima.2008.07.107
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
During the 2005-2007 JET experimental campaigns a Single Crystal Diamond (SCD) detector covered with a 2-mu m thick LiF film 95% enriched in Li-6 was installed at JET and operated continuously during the whole experimental campaign with the goal to measure both the total and the time-dependent neutron emission from plasmas. After reviewing the history of diamond as neutron detector for tokamak application, this paper reports on the experimental measurements performed during that time window. The results are compared with those obtained with detectors routinely working at JET (Fission Chambers and silicon diodes). In particular it was demonstrated that using an SCD detector covered with a (LiF)-Li-6 film it has been possible to discriminate between the total and the 14-MeV neutrons coming from triton burn-up. This allowed, for the first time using a single detector, the simultaneous measurement of both the total and 14-MeV neutron yields as well as their time dependency with very good reliability and stability. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:616 / 622
页数:7
相关论文
共 23 条
[1]   Radiation hard diamond sensors for future tracking applications [J].
Adam, W. ;
de Boer, W. ;
Borchi, E. ;
Bruzzi, M. ;
Colledani, C. ;
D'Angelo, P. ;
Dabrowski, V. ;
Dulinski, W. ;
van Eijk, B. ;
Eremin, V. ;
Fizzotti, F. ;
Frais-Koelbl, H. ;
Furetta, C. ;
Gan, K. K. ;
Gorisek, A. ;
Griesmayer, E. ;
Grigoriev, E. ;
Hartjes, F. ;
Hrubec, J. ;
Huegging, F. ;
Kagan, H. ;
Kaplon, J. ;
Kass, R. ;
Knoepfle, K. T. ;
Krammer, M. ;
Lange, W. ;
Logiudice, A. ;
Manfredotti, C. ;
Mathes, M. ;
Menichelli, D. ;
Mishina, M. ;
Moroni, L. ;
Noomen, J. ;
Oh, A. ;
Pernegger, H. ;
Pernicka, M. ;
Potenza, R. ;
Riester, J. L. ;
Rudge, A. ;
Sala, S. ;
Schnetzer, S. ;
Sciortino, S. ;
Stone, R. ;
Sutera, C. ;
Trischuk, W. ;
Velthuis, J. J. ;
Vincenzo, B. ;
Weilhammer, P. ;
Weingarten, J. ;
Wermes, N. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 565 (01) :278-283
[2]   Radiation hardness of a polycrystalline chemical-vapor-deposited diamond detector irradiated with 14 MeV neutrons [J].
Angelone, M ;
Pillon, M ;
Balducci, A ;
Marinelli, M ;
Milani, E ;
Morgada, ME ;
Pucella, G ;
Tucciarone, A ;
Verona-Rinati, G ;
Ochiai, K ;
Nishitani, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (02)
[3]   Time dependent 14 MeV neutrons measurement using a polycrystalline chemical vapor deposited diamond detector at the JET tokamak [J].
Angelone, M ;
Pillon, M ;
Bertalot, L ;
Orsitto, F ;
Marinelli, M ;
Milani, E ;
Pucella, G ;
Tucciarone, A ;
Verona-Rinati, G ;
Popovichev, S ;
Murari, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (01)
[4]   Development and application of CVD diamond detectors to 14 MeV neutron flux monitoring [J].
Angelone, M ;
Pillon, M ;
Marinelli, M ;
Paoletti, A ;
Tucciarone, A ;
Pucella, G ;
Verona-Rinati, G .
RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) :233-236
[5]   Synthesis and characterization of a single-crystal chemical-vapor-deposition diamond particle detector [J].
Balducci, A ;
Marinelli, M ;
Milani, E ;
Morgada, ME ;
Pucella, G ;
Tucciarone, A ;
Verona-Rinati, G ;
Angelone, M ;
Pillon, M .
APPLIED PHYSICS LETTERS, 2005, 86 (21) :1-3
[6]  
Balducci A., 2005, APPL PHYS LETT, V86, P19350
[7]   Radiation hardness studies of CVD diamond detectors [J].
Bauer, C ;
Baumann, I ;
Colledani, C ;
Conway, J ;
Delpierre, P ;
Djama, F ;
Dulinski, W ;
Fallou, A ;
Gan, KK ;
Gilmore, RS ;
Grigoriev, E ;
Hallewell, G ;
Han, S ;
Hessing, T ;
Honschied, K ;
Hrubec, J ;
Husson, D ;
Kagan, H ;
Kania, D ;
Kass, R ;
Kinnison, W ;
Knopfle, KT ;
Krammer, M ;
Llewellyn, TJ ;
Manfredi, PF ;
Pan, LS ;
Pernegger, H ;
Pernicka, M ;
Plano, R ;
Re, V ;
Roe, S ;
Rudge, A ;
Schaeffer, M ;
Schnetzer, S ;
Somalwar, S ;
Speziali, V ;
Stone, R ;
Tapper, RJ ;
Tesarek, R ;
Trischuk, W ;
Turchetta, R ;
Thomson, GB ;
Wagner, R ;
Weilhammer, P ;
White, C ;
Ziock, H ;
Zoeller, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 367 (1-3) :207-211
[8]  
Field J.E., 1979, PROPERTIES DIAMOND
[10]   High carrier mobility in single-crystal plasma-deposited diamond [J].
Isberg, J ;
Hammersberg, J ;
Johansson, E ;
Wikström, T ;
Twitchen, DJ ;
Whitehead, AJ ;
Coe, SE ;
Scarsbrook, GA .
SCIENCE, 2002, 297 (5587) :1670-1672