The use of a mini-κ goniometer head in macromolecular crystallography diffraction experiments

被引:41
|
作者
Brockhauser, Sandor [1 ,2 ]
Ravelli, Raimond B. G. [3 ]
McCarthy, Andrew A. [1 ,2 ]
机构
[1] European Mol Biol Lab, F-38042 Grenoble, France
[2] UJF, EMBL, CNRS, UMI 3265,Unit Virus Host Cell Interact, F-38043 Grenoble, France
[3] Leiden Univ, Med Ctr LUMC, NL-2300 RC Leiden, Netherlands
关键词
DATA-COLLECTION STRATEGIES; X-RAY-ABSORPTION; RADIATION-DAMAGE; ANOMALOUS SIGNAL; TRANSFER-RNA; CRYSTALS; BEAMLINE;
D O I
10.1107/S0907444913003880
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Most macromolecular crystallography (MX) diffraction experiments at synchrotrons use a single-axis goniometer. This markedly contrasts with small-molecule crystallography, in which the majority of the diffraction data are collected using multi-axis goniometers. A novel miniaturized kappa-goniometer head, the MK3, has been developed to allow macromolecular crystals to be aligned. It is available on the majority of the structural biology beamlines at the ESRF, as well as elsewhere. In addition, the Strategy for the Alignment of Crystals (STAC) software package has been developed to facilitate the use of the MK3 and other similar devices. Use of the MK3 and STAC is streamlined by their incorporation into online analysis tools such as EDNA. The current use of STAC and MK3 on the MX beamlines at the ESRF is discussed. It is shown that the alignment of macromolecular crystals can result in improved diffraction data quality compared with data obtained from randomly aligned crystals.
引用
收藏
页码:1241 / 1251
页数:11
相关论文
共 50 条
  • [21] Use of electrochemistry in mini-/micro-LED and VCSELs
    Kang, Jin-ho
    Elafandy, Rami
    Li, Bingjun
    Song, Jie
    Han, Jung
    LIGHT-EMITTING DEVICES, MATERIALS, AND APPLICATIONS XXVI, 2022, 12022
  • [23] Improvements toward highly accurate diffraction experiments at the macromolecular micro-crystallography beamline BL-17A
    Yamada, Yusuke
    Chavas, Leonard M. G.
    Igarashi, Noriyuki
    Hiraki, Masahiko
    Wakatsuki, Soichi
    Matsugaki, Naohiro
    JOURNAL OF SYNCHROTRON RADIATION, 2013, 20 : 938 - 942
  • [24] MULTIWAVELENGTH ANOMALOUS DIFFRACTION AS A DIRECT PHASING VEHICLE IN MACROMOLECULAR CRYSTALLOGRAPHY
    HENDRICKSON, WA
    HORTON, JR
    MURTHY, HMK
    PAHLER, A
    SMITH, JL
    SYNCHROTRON RADIATION IN STRUCTURAL BIOLOGY, 1989, 51 : 317 - 324
  • [25] THE USE OF AN IMAGING PROPORTIONAL COUNTER IN MACROMOLECULAR CRYSTALLOGRAPHY
    HOWARD, AJ
    GILLILAND, GL
    FINZEL, BC
    POULOS, TL
    OHLENDORF, DH
    SALEMME, FR
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1987, 20 (05) : 383 - 387
  • [26] Use of mmCIF in the Publication of Macromolecular Crystallography Communications
    McMahon, Brian
    Strickland, Peter R.
    Einspahr, Howard M.
    Guss, Mitchell
    Jones, Louise E.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C128 - C128
  • [27] Progress in macromolecular crystallography depends on further miniaturization of crystallization experiments
    Gorrec, Fabrice
    DRUG DISCOVERY TODAY, 2014, 19 (10) : 1505 - 1507
  • [28] USE OF A 3-CIRCLE GONIOMETER FOR DIFFRACTION MEASUREMENTS
    WILLIS, BTM
    BRITISH JOURNAL OF APPLIED PHYSICS, 1962, 13 (11): : 548 - &
  • [29] THE PROCESSING OF DIFFRACTION DATA TAKEN ON A SCREENLESS WEISSENBERG CAMERA FOR MACROMOLECULAR CRYSTALLOGRAPHY
    HIGASHI, T
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1989, 22 : 9 - 18
  • [30] Improved R-factors for diffraction data analysis in macromolecular crystallography
    Diederichs, K
    Karplus, PA
    NATURE STRUCTURAL BIOLOGY, 1997, 4 (04): : 269 - 275