Evaluation of 4 corneal astigmatic marking methods

被引:74
作者
Popp, Nina [1 ]
Hirnschall, Nino [1 ,2 ]
Maedel, Sophie [1 ]
Findl, Oliver [1 ,2 ]
机构
[1] Hanusch Hosp, Vienna Inst Res Ocular Surg, A-1140 Vienna, Austria
[2] Moorfields Eye Hosp NHS Fdn Trust, London, England
关键词
INTRAOCULAR-LENS; RESIDUAL ASTIGMATISM; REFRACTIVE SURGERY; CATARACT;
D O I
10.1016/j.jcrs.2012.07.039
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare 4 devices used to mark the cornea before astigmatism-reducing surgery. SETTING: Hanusch Krankenhaus, Vienna, Austria. DESIGN: Randomized examiner-masked clinical trial. METHODS: Patients were randomly allocated to 1 of 4 groups for preoperative corneal marking in the sitting position. The 4 methods used were marking at the slitlamp with an insulin needle, a pendular marker, a bubble marker, and a tonometer marker. The marks were then documented with a standardized photographic technique, and the rotational deviation and vertical misalignment were assessed. RESULTS: The study enrolled 60 patients. The pendular-marking device showed the least rotational deviation to the reference meridian (mean 1.8 degrees). There was no statistically significant difference between slitlamp marking and pendular marking (P = .05); however, there was a significant difference between the pendular marker and the bubble marker and between the pendular marker and the tonometer marker (P = .01 and P < .01, respectively). The least vertical misalignment was observed with the slitlamp-marking device (mean 0.28 mm). There was no statistically significant difference in vertical misalignment between the 4 groups. CONCLUSIONS: All marking devices showed a slight deviation to the horizontal reference meridian. Because small deviations of the meridian can result in a relevant reduction in the astigmatism-reducing effect with toric intraocular lenses, accurate marking of the cornea before surgery is critical due to the variable cyclotorsion caused by a change from the upright to the supine position.
引用
收藏
页码:2094 / 2099
页数:6
相关论文
共 11 条
[1]   Surgical correction of astigmatism during cataract surgery [J].
Buckhurst, Phillip J. ;
Wolffsohn, James S. ;
Davies, Leon N. ;
Naroo, Shehzad A. .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2010, 93 (06) :409-418
[2]   Residual astigmatism produced by toric intraocular lens rotation [J].
Felipe, Adelina ;
Artigas, Jose M. ;
Diez-Ajenjo, Amparo ;
Garcia-Domene, Carmen ;
Alcocer, Pablo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (10) :1895-1901
[3]   Analysis of biometry and prevalence data for corneal astigmatism in 23 239 eyes [J].
Hoffmann, Peter Christian ;
Huetz, Werner W. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (09) :1479-1485
[4]   Rotational stability of a single-piece toric acrylic intraocular lens [J].
Koshy, John J. ;
Nishi, Yutaro ;
Hirnschall, Nino ;
Crnej, Alja ;
Gangwani, Vinod ;
Maurino, Vincenzo ;
Findl, Oliver .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (10) :1665-1670
[5]   Toric Intraocular Lenses-Theory, Matrix Calculations, and Clinical Practice [J].
Langenbucher, Achim ;
Viestenz, Anja ;
Szentmary, Nora ;
Behrens-Baumann, Wolfgang ;
Viestenz, Arne .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (07) :611-622
[6]   Assessment and statistics of surgically induced astigmatism [J].
Naeser, Kristian .
ACTA OPHTHALMOLOGICA, 2008, 86 (03) :349-349
[7]   Sources of error in intraocular lens power calculation [J].
Norrby, Sverker .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03) :368-376
[8]  
Sharma BR, 2009, NEPAL J OPHTHALMOL, V1, P90
[9]   Correction of pre-existing astigmatism during cataract surgery: comparison between the effects of opposite clear corneal incisions and a single clear corneal incision [J].
Simon, GJB ;
Desatnik, H .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 243 (04) :321-326
[10]   Cyclotorsion: A possible cause of residual astigmatism in refractive surgery [J].
Tjon-Fo-Sang, MJ ;
de Faber, JTHN ;
Kingma, C ;
Beekhuis, WH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (04) :599-602