Mechanical Failure After Locking Plate Fixation of Unstable Intertrochanteric Femur Fractures

被引:85
|
作者
Streubel, Philipp N. [1 ]
Moustoukas, Michael J. [1 ]
Obremskey, William T. [1 ]
机构
[1] Vanderbilt Univ Sch Med, Dept Orthoped, Orthoped Trauma Serv, Nashville, TN 37232 USA
关键词
femur fracture; hip fracture; locking plate; internal fixation plates; mechanical failure; complications; malunion; nonunion; PROXIMAL FEMORAL FRACTURES; COMPRESSION HIP-SCREW; MEDOFF SLIDING PLATE; INTRAMEDULLARY NAIL; DHS;
D O I
10.1097/BOT.0b013e318251930d
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: The aim of this study was analyze modes of mechanical failure in a consecutive cohort of patients and establish possible risk factors. Design: This was a retrospective cohort study. Setting: The study was conducted at an academic level-1 trauma center. Patients: Twenty-nine patients (mean age 56 years, range 21-92; 45% males, 41% smokers, 17% diabetic, mean body mass index 26.9, range 20-56) with 30 OTA 31A3 fractures treated between 2003 and 2007 were included. Treatment: Operative fixation using 4.5-mm locking compression plate (LCP) proximal femur plate (Synthes, Paoli, PA). Main Outcome Measurements: Mechanical failure was defined as loss of alignment of at least 108 or shortening of at least 2 cm. Secondary outcomes included patient and fixation construct variables as possible predictors for mechanical failure. Results: At 20 months of follow-up, 11 failures (37%) occurred. Mean time to failure was 18 weeks (range 2-84). Cumulative failure rates were 10%, 20%, 27%, and 33% at 1, 2, 6, and 12 months, respectively. The most frequent failure mode was varus collapse with screw cut out (5 cases). There was no statistically significant difference between groups with regards to age, body mass index, diabetes, or smoking habit. The presence of a "kickstand screw" and medial cortical reduction were not significantly different in cases with and without failure. Proximal screw number and type were similar in both groups. Conclusions: A high rate of mechanical failure can be expected with proximal locking plate fixation of unstable proximal femur fractures. The use of a "kickstand" screw could not be established to reduce the risk for mechanical failure.
引用
收藏
页码:22 / 28
页数:7
相关论文
共 50 条
  • [1] External fixation in unstable intertrochanteric fractures of femur
    Kamble, KT
    Murthy, BS
    Pal, V
    Rao, KS
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1996, 27 (02): : 139 - 142
  • [2] External fixation in unstable intertrochanteric fractures of femur
    Krikler, SJ
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1996, 27 (10): : 756 - 756
  • [3] Application of proximal femur locking compression plate for unstable four part intertrochanteric fractures
    夏青
    外科研究与新技术, 2011, 20 (02) : 108 - 108
  • [4] Locking Plate Fixation for Paediatric Femur Fractures
    Sawalha, Seif
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2010, 30 (05) : 519 - 519
  • [5] Locking plate fixation for pediatric femur fractures
    Hedequist, Daniel
    Bishop, Julius
    Hresko, Timothy
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2008, 28 (01) : 6 - 9
  • [6] UNSTABLE INTERTROCHANTERIC FRACTURES OF FEMUR
    SARMIENTO, A
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1973, (92) : 77 - 85
  • [7] BENT PLATE FIXATION IN COMBINED INTERTROCHANTERIC AND SUBTROCHANTERIC FRACTURES OF THE FEMUR
    ROWE, SM
    CHUNG, JY
    MOON, ES
    SONG, EK
    ORTHOPEDICS, 1991, 14 (10) : 1123 - 1128
  • [8] Optimal side plate fixation for unstable intertrochanteric flip fractures
    Yian, EH
    Banerji, I
    Matthews, LS
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (04) : 254 - 259
  • [9] UNSTABLE INTERTROCHANTERIC SUBTROCHANTERIC FRACTURES OF THE FEMUR
    WHITELAW, GP
    SEGAL, D
    SANZONE, CF
    OBER, NS
    HADLEY, N
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (252) : 238 - 245
  • [10] INTERTROCHANTERIC FEMORAL FRACTURES - MECHANICAL FAILURE AFTER INTERNAL-FIXATION
    DAVIS, TRC
    SHER, JL
    HORSMAN, A
    SIMPSON, M
    PORTER, BB
    CHECKETTS, RG
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01): : 26 - 31