Radiation dose to the fetus for pregnant patients undergoing multidetector CT imaging: Monte Carlo Simulations estimating fetal dose for a range of gestational age and patient size1

被引:107
作者
Angel, Erin [1 ,2 ]
Wellnitz, Clinton V. [3 ]
Goodsitt, Mitchell M. [4 ]
Yaghmai, Nazanin [1 ,2 ]
DeMarco, John J. [1 ,2 ]
Cagnon, Christopher H. [1 ,2 ]
Sayre, James W. [1 ,2 ]
Cody, Dianna D. [5 ]
Stevens, Donna M. [5 ]
Primak, Andrew N. [6 ]
McCollough, Cynthia H. [6 ]
McNitt-Gray, Michael F. [1 ,2 ]
机构
[1] Univ Calif Los Angeles, David A Geffen Sch Med, Dept Radiol, Los Angeles, CA 90024 USA
[2] Univ Calif Los Angeles, David A Geffen Sch Med, Dept Radiat Oncol, Los Angeles, CA 90024 USA
[3] Mayo Clin, Dept Diagnost Radiol, Scottsdale, AZ USA
[4] Univ Michigan Hosp, Dept Radiol, Ann Arbor, MI 48109 USA
[5] Univ Texas MD Anderson Canc Ctr, Div Diagnost Imaging, Houston, TX 77030 USA
[6] Mayo Clin, Coll Med, Dept Radiol, Rochester, MN USA
关键词
D O I
10.1148/radiol.2491071665
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To use Monte Carlo simulations of a current-technology multidetector computed tomographic (CT) scanner to investigate fetal radiation dose resulting from an abdominal and pelvic examination for a range of actual patient anatomies that include variation in gestational age and maternal size. Materials and Methods: Institutional review board approval was obtained for this HIPAA-compliant retrospective study. Twenty-four models of maternal and fetal anatomy were created from image data from pregnant patients who had previously undergone clinically indicated CT examination. Gestational age ranged from less than 5 weeks to 36 weeks. Simulated helical scans of the abdominal and pelvic region were performed, and a normalized dose (in milligrays per 100 mAs) was calculated for each fetus. Stepwise multiple linear regression was performed to analyze the correlation of dose with gestational age and anatomic measurements of maternal size and fetal location. Results were compared with several existing fetal dose estimation methods. Results: Normalized fetal dose estimates from the Monte Carlo simulations ranged from 7.3 to 14.3 mGy/100 mAs, with an average of 10.8 mGy/100 mAs. Previous methods yielded values of 10-14 mGy/100 mAs. The correlation between gestational age and fetal dose was not significant ( P = .543). Normalized fetal dose decreased linearly with increasing patient perimeter (R-2 = 0.681, P < .001), and a two-factor model with patient perimeter and fetal depth demonstrated a strong correlation with fetal dose (R-2 = 0.799, P < .002). Conclusion: A method for the estimation of fetal dose from models of actual patient anatomy that represented a range of gestational age and patient size was developed. Fetal dose correlated with maternal perimeter and varied more than previously recognized. This correlation improves when maternal size and fetal depth are combined. (c) RSNA, 2008.
引用
收藏
页码:220 / 227
页数:8
相关论文
共 23 条
  • [11] Radiation exposure and pregnancy: When should we be concerned?
    McCollough, Cynthia H.
    Schueler, Beth A.
    Atwell, Thomas D.
    Braun, Natalie N.
    Regner, Dawn M.
    Brown, Douglas L.
    LeRoy, Andrew J.
    [J]. RADIOGRAPHICS, 2007, 27 (04) : 909 - U5
  • [12] AAPM/RSNA physics tutorial for residents:: Topics in CT -: Radiation dose in CT1
    McNitt-Gray, MF
    [J]. RADIOGRAPHICS, 2002, 22 (06) : 1541 - 1553
  • [13] Nagel HD, 2000, RAD EXPOSURE COMPUTE
  • [14] Fetal position and size data for dose estimation
    Osei, EK
    Faulkner, K
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (856) : 363 - 370
  • [15] Development of a 30-week-pregnant female tomographic model from computed tomography (CT) images for Monte Carlo organ dose calculations
    Shi, CY
    Xu, XG
    [J]. MEDICAL PHYSICS, 2004, 31 (09) : 2491 - 2497
  • [16] A METHOD FOR DESCRIBING THE DOSES DELIVERED BY TRANSMISSION-X-RAY COMPUTED-TOMOGRAPHY
    SHOPE, TB
    GAGNE, RM
    JOHNSON, GC
    [J]. MEDICAL PHYSICS, 1981, 8 (04) : 488 - 495
  • [17] SNYDER WS, 1969, J NUCL MED S, V3, P7
  • [18] CT-Expo - a novel program for dose evaluation in CT
    Stamm, G
    Nagel, HD
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (12): : 1570 - 1576
  • [19] Organ and effective doses in newborn patients during helical multislice computed tomography examination
    Staton, Robert J.
    Lee, Choonik
    Lee, Choonsik
    Williams, Matt D.
    Hintenlang, David E.
    Arreola, Manuel M.
    Williams, Jonathon L.
    Bolch, Wesley E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (20) : 5151 - 5166
  • [20] Waters, 1999, MCNPX USERS MANUAL V