Radiation dose to the fetus for pregnant patients undergoing multidetector CT imaging: Monte Carlo Simulations estimating fetal dose for a range of gestational age and patient size1

被引:106
|
作者
Angel, Erin [1 ,2 ]
Wellnitz, Clinton V. [3 ]
Goodsitt, Mitchell M. [4 ]
Yaghmai, Nazanin [1 ,2 ]
DeMarco, John J. [1 ,2 ]
Cagnon, Christopher H. [1 ,2 ]
Sayre, James W. [1 ,2 ]
Cody, Dianna D. [5 ]
Stevens, Donna M. [5 ]
Primak, Andrew N. [6 ]
McCollough, Cynthia H. [6 ]
McNitt-Gray, Michael F. [1 ,2 ]
机构
[1] Univ Calif Los Angeles, David A Geffen Sch Med, Dept Radiol, Los Angeles, CA 90024 USA
[2] Univ Calif Los Angeles, David A Geffen Sch Med, Dept Radiat Oncol, Los Angeles, CA 90024 USA
[3] Mayo Clin, Dept Diagnost Radiol, Scottsdale, AZ USA
[4] Univ Michigan Hosp, Dept Radiol, Ann Arbor, MI 48109 USA
[5] Univ Texas MD Anderson Canc Ctr, Div Diagnost Imaging, Houston, TX 77030 USA
[6] Mayo Clin, Coll Med, Dept Radiol, Rochester, MN USA
关键词
D O I
10.1148/radiol.2491071665
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To use Monte Carlo simulations of a current-technology multidetector computed tomographic (CT) scanner to investigate fetal radiation dose resulting from an abdominal and pelvic examination for a range of actual patient anatomies that include variation in gestational age and maternal size. Materials and Methods: Institutional review board approval was obtained for this HIPAA-compliant retrospective study. Twenty-four models of maternal and fetal anatomy were created from image data from pregnant patients who had previously undergone clinically indicated CT examination. Gestational age ranged from less than 5 weeks to 36 weeks. Simulated helical scans of the abdominal and pelvic region were performed, and a normalized dose (in milligrays per 100 mAs) was calculated for each fetus. Stepwise multiple linear regression was performed to analyze the correlation of dose with gestational age and anatomic measurements of maternal size and fetal location. Results were compared with several existing fetal dose estimation methods. Results: Normalized fetal dose estimates from the Monte Carlo simulations ranged from 7.3 to 14.3 mGy/100 mAs, with an average of 10.8 mGy/100 mAs. Previous methods yielded values of 10-14 mGy/100 mAs. The correlation between gestational age and fetal dose was not significant ( P = .543). Normalized fetal dose decreased linearly with increasing patient perimeter (R-2 = 0.681, P < .001), and a two-factor model with patient perimeter and fetal depth demonstrated a strong correlation with fetal dose (R-2 = 0.799, P < .002). Conclusion: A method for the estimation of fetal dose from models of actual patient anatomy that represented a range of gestational age and patient size was developed. Fetal dose correlated with maternal perimeter and varied more than previously recognized. This correlation improves when maternal size and fetal depth are combined. (c) RSNA, 2008.
引用
收藏
页码:220 / 227
页数:8
相关论文
共 15 条
  • [1] Radiation Dose to the Fetus for Pregnant Patients Undergoing Multidetector CT Imaging: Monte Carlo Simulations Estimating Fetal Dose for a Range of Gestational Age and Patient Size (vol 249, pg 220, 2008)
    Angel, E.
    Wellnitz, C., V
    Goodsitt, M. M.
    Yaghmai, N.
    DeMarco, J. J.
    Cagnon, C. H.
    Sayre, J. W.
    Cody, D. D.
    Stevens, D. M.
    Primak, A. N.
    McCollough, C. H.
    McNitt-Gray, M. F.
    RADIOLOGY, 2010, 255 (02) : 664 - 664
  • [2] Monte Carlo Based Multidetector CT Modeling and Dose Calculations for Pregnant Patients
    Gu, J.
    Caracappa, P.
    Xu, X.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [3] Estimating surface radiation dose from multidetector CT: Cylindrical phantoms, anthropomorphic phantoms and Monte Carlo simulations
    DeMarco, JJ
    Cagnon, CH
    Cody, DD
    Stevens, DM
    McCollough, CH
    O'Daniel, J
    McNitt-Gray, MF
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 102 - 112
  • [4] Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose
    DeMarco, J. J.
    Cagnon, C. H.
    Cody, D. D.
    Stevens, D. M.
    McCollough, C. H.
    Zankl, M.
    Angel, E.
    McNitt-Gray, M. F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (09): : 2583 - 2597
  • [5] Radiation dose from MDCT using Monte Carlo simulations: Estimating fetal dose due to pulmonary embolism scans accounting for overscan
    Angel, E.
    Wellnitz, C.
    Goodsitt, M.
    DeMarco, J.
    Cagnon, C.
    Ghatali, M.
    Cody, D.
    Stevens, D.
    McCollough, C.
    Primak, A.
    McNitt-Gray, M.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [6] MONTE CARLO SIMULATION OF RADIOTHERAPY FOR BREAST CANCER IN PREGNANT PATIENTS: HOW TO REDUCE THE RADIATION DOSE AND RISKS TO FETUS?
    Mazonakis, Michalis
    Tzedakis, Antonis
    Damilakis, John
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (01) : 10 - 16
  • [7] Patient-Specific Estimate of Effective Dose and Fetus Dose in Potentially Pregnant Pediatric Patients Undergoing Low Dose Pelvis CT Scan
    Nosrati, R.
    Callahan, M.
    Voss, S.
    Zhang, D.
    MEDICAL PHYSICS, 2022, 49 (06) : E396 - E396
  • [8] Patient-specific fetal radiation dosimetry for pregnant patients undergoing abdominal and pelvic CT imaging
    Qu, Shuiyin
    Liu, Haikuan
    Xie, Tianwu
    Giger, Maryellen L.
    Quan, Guotao
    Zaidi, Habib
    MEDICAL PHYSICS, 2023, 50 (06) : 3801 - 3815
  • [9] Personalized 3D Dose Prediction for Intrabeam Treatments Based On Patient CT Imaging with Monte Carlo GATE Simulations
    Bouzid, D.
    Nicolas, B.
    Dupre, P.
    Bert, J.
    Pradier, O.
    Visvikis, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [10] CT Dose Reduction with Tube Current Modulation: A Case Study of Fetal Doses to Pregnant Patients Using Monte Carlo Computational Phantoms
    Gu, J.
    Liu, B.
    Xu, X.
    MEDICAL PHYSICS, 2010, 37 (06)