Optical coherence tomography guided in-stent thrombus removal in patients with acute coronary syndromes

被引:15
作者
Di Giorgio, Alessandro [1 ,2 ]
Capodanno, Davide [2 ,3 ]
Ramazzotti, Vito [1 ]
Imola, Fabrizio [1 ,4 ]
Mallus, Maria Teresa [1 ]
Stazi, Filippo [1 ,4 ]
Paoletti, Giulia [4 ]
Biondi-Zoccai, Giuseppe [4 ,5 ]
Tamburino, Corrado [2 ,3 ]
Prati, Francesco [1 ,4 ]
机构
[1] San Giovanni Hosp, I-00184 Rome, Italy
[2] Ferrarotto Hosp, Dept Cardiol, Catania, Italy
[3] ETNA Fdn, Catania, Italy
[4] CLI Fdn, Rome, Italy
[5] Univ Roma La Sapienza, Dept Medicosurg Sci & Biotechnol, Latina, Italy
关键词
Acute coronary syndrome; Optical coherence tomography; Quantitative coronary angiography; Thrombosis; ELEVATION MYOCARDIAL-INFARCTION; DRUG-ELUTING STENTS; INTRAVASCULAR ULTRASOUND; TISSUE COVERAGE; TASK-FORCE; ANGIOPLASTY; INTERVENTION; IMPLANTATION; ANGIOGRAPHY; APPOSITION;
D O I
10.1007/s10554-013-0191-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The persistence of thrombus inside stent struts is a frequent event in patients with acute coronary syndromes (ACS) undergoing percutaneous coronary intervention (PCI), and this phenomenon might be associated with an increased risk of stent thrombosis. We sought to quantify by means of optical coherence tomography (OCT) the presence of in-stent thrombus after achievement of an optimal angiographic result in patients with ACS undergoing PCI. In addition, we evaluated the feasibility and safety of an OCT-guided strategy of in-stent thrombus removal. Eighty consecutive patients with ACS undergoing PCI were treated with two different strategies equally divided into two groups: angio-guided PCI, and OCT-guided PCI, in which additional OCT-driven in-stent balloon dilatation was adopted to reduce thrombus encroachment of the lumen. Overall in-stent thrombus area was 4.3 % with a maximal thrombus encroachment of 16.7 %. In the OCT-guided group, use of high pressure intra-stent dilatation led to a significant increase in stented area (9.6 +/- A 2.4 vs. 9.1 +/- A 2.49 mm(2), p = 0.002) and lumen area (9.2 +/- A 2.4 vs. 8.7 +/- A 2.3 mm(2), p < 0.001) and also significantly decreased in-stent thrombus area in absolute (0.35 +/- A 0.29 vs. 0.42 +/- A 0.30 mm(2), p = 0.001) and relative terms (3.58 +/- A 3.25 vs. 4.53 +/- A 3.01 %, p = 0.001). Values of TIMI flow, frame count and blush grade, as well as clinical outcomes were not detrimentally affected by such additional dilatations. The use of additional OCT-driven in-stent balloon dilatations is feasible, safe and might be effective in the treatment of in-stent thrombus for patients with ACS.
引用
收藏
页码:989 / 996
页数:8
相关论文
共 33 条
[1]   ACC/AHA 2007 Guidelines for the Management of Patients With unstable Angina/Non-ST-Elevation Myocardial Infarction A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 2002 Guidelines for the Management of Patients With Unstable Angina/Non-ST-Elevation Myocardial Infarction) Developed in Collaboration with the American College of Emergency Physicians, the Society for Cardiovascular Angiography and Interventions, and the Society of Thoracic Surgeons Endorsed by the American Association of Cardiovascular and Pulmonary Rehabilitation and the Society for Academic Emergency Medicine [J].
Anderson, Jeffrey L. ;
Adams, Cynthia D. ;
Antman, Elliott M. ;
Bridges, Charles R. ;
Califf, Robert M. ;
Casey, Donald E., Jr. ;
Chavey, William E. ;
Fesmire, Francis M. ;
Hochman, Judith S. ;
Levin, Thomas N. ;
Lincoff, A. Michael ;
Peterson, Eric D. ;
Theroux, Pierre ;
Wenger, Nanette Kass ;
Wright, R. Scott ;
Smith, Sidney C. ;
Jacobs, Alice K. ;
Halperin, Jonathan L. ;
Hunt, Sharon A. ;
Krumholz, Harlan M. ;
Kushner, Frederick G. ;
Lytle, Bruce W. ;
Nishimura, Rick ;
Ornato, Joseph P. ;
Page, Richard L. ;
Riegel, Barbara .
CIRCULATION, 2007, 116 (07) :E148-E304
[2]   Intracoronary Optical Coherence Tomography: A Comprehensive Review Clinical and Research Applications [J].
Bezerra, Hiram G. ;
Costa, Marco A. ;
Guagliumi, Giulio ;
Rollins, Andrew M. ;
Simon, Daniel I. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (11) :1035-1046
[3]   Comparison of optical coherence tomography and intravascular ultrasound for the assessment of in-stent tissue coverage after stent implantation [J].
Capodanno, Davide ;
Prati, Francesco ;
Pawlowsky, Tomasz ;
Cera, Maria ;
La Manna, Alessio ;
Albertucci, Mario ;
Tamburino, Corrado .
EUROINTERVENTION, 2009, 5 (05) :538-543
[4]   Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation [J].
Cook, Stephane ;
Wenaweser, Peter ;
Togni, Mario ;
Billinger, Michael ;
Morger, Cyrill ;
Seiler, Christian ;
Vogel, Rolf ;
Hess, Otto ;
Meier, Bernhard ;
Windecker, Stephan .
CIRCULATION, 2007, 115 (18) :2426-2434
[5]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[6]   THROMBOSIS AND ACUTE CORONARY-ARTERY LESIONS IN SUDDEN CARDIAC ISCHEMIC DEATH [J].
DAVIES, MJ ;
THOMAS, A .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 310 (18) :1137-1140
[7]   Intravascular ultrasound-guided optimized stent deployment - Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study) [J].
de Jaegere, P ;
Mudra, H ;
Figulla, H ;
Almagor, Y ;
Doucet, S ;
Penn, I ;
Colombo, A ;
Hamm, C ;
Bartorelli, A ;
Rothman, M ;
Nobuyoshi, M ;
Yamaguchi, T ;
Voudris, V ;
DiMario, C ;
Makovski, S ;
Hausmann, D ;
Rowe, S ;
Rabinovich, S ;
Sunamura, M ;
van Es, GA .
EUROPEAN HEART JOURNAL, 1998, 19 (08) :1214-1223
[8]  
Fitzgerald PJ, 2000, CIRCULATION, V102, P523
[9]   Relationship between TIMI frame count and clinical outcomes after thrombolytic administration [J].
Gibson, CM ;
Murphy, SA ;
Rizzo, MJ ;
Ryan, KA ;
Marble, SJ ;
McCabe, CH ;
Cannon, CP ;
Van de Werf, F ;
Braunwald, E .
CIRCULATION, 1999, 99 (15) :1945-1950
[10]   Incomplete Stent Apposition and Delayed Tissue Coverage Are More Frequent in Drug-Eluting Stents Implanted During Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction Than in Drug-Eluting Stents Implanted for Stable/Unstable Angina Insights From Optical Coherence Tomography [J].
Gonzalo, Nieves ;
Barlis, Peter ;
Serruys, Patrick W. ;
Garcia-Garcia, Hector M. ;
Onuma, Yoshinobu ;
Ligthart, Jurgen ;
Regar, Evelyn .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (05) :445-452