PVC-based Mn(III) porphyrin membrane coated graphite electrode for determination of histidine

被引:98
作者
Amini, MK [1 ]
Shahrokhian, S [1 ]
Tangestaninejad, S [1 ]
机构
[1] Univ Esfahan, Dept Chem, Esfahan 81744, Iran
关键词
D O I
10.1021/ac9812633
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction, performance characteristics, and application of a polymeric membrane coated on a graphite electrode with unique selectivity toward histidine are reported. The electrode was prepared by incorporating chloro(5,10,15,20-tetraphenylporphyrinato) manganese(III) [Mn(TPP)Cl] into a plasticized poly(vinyl chloride) membrane. The influences of membrane composition, pH, and foreign ions were investigated. Calibration plots with near Nernstian slopes for histidine were observed, -55.4 mV/decade, over a linear range of four decades of concentration (1 x 10(-5) to 1 x 10(-1) M). The electrode has a detection limit of 5 x 10(-6) M histidine and shows a fast response time of about 1 min. The electrode shows high selectivities toward histidine over several amino acids and common inorganic anions.
引用
收藏
页码:2502 / 2505
页数:4
相关论文
共 50 条
  • [31] PVC membrane and coated graphite potentiometric sensors based on 1-phenyl-3-pyridin-2-yl-thiourea for selective determination of iron(III)
    Motlagh, Masoud Ghanei
    Taher, Mohammad Ali
    Ahmadi, Ali
    ELECTROCHIMICA ACTA, 2010, 55 (22) : 6724 - 6730
  • [32] Determination of cerium ion by polymeric membrane and coated graphite electrode based on novel pendant armed macrocycle
    Singh, Ashok K.
    Singh, Prerna
    ANALYTICA CHIMICA ACTA, 2010, 675 (02) : 170 - 180
  • [33] Coated-graphite electrode based on poly(vinyl chloride)-aluminum phthalocyanine membrane for determination of salicylate
    Shahrokhian, S
    Amini, MK
    Kolagar, S
    Tangestaninejad, S
    MICROCHEMICAL JOURNAL, 1999, 63 (02) : 302 - 310
  • [34] An enantioselective polyaniline-coated membrane electrode based on chiral salen Mn(III) as chiral selector
    Xu, Lan
    Hou, Jingya
    Yang, Yuanyuan
    Li, Bingxin
    Chen, Shaozhu
    ANALYTICAL METHODS, 2012, 4 (03) : 807 - 811
  • [35] Novel gadolinium PVC-based membrane sensor based on omeprazole as an antibiotic
    Ganjali, MR
    Tahami, M
    Shamsipur, M
    Poursaberi, T
    Haghgoo, S
    Hosseini, M
    ELECTROANALYSIS, 2003, 15 (12) : 1038 - 1042
  • [36] Graphite coated membrane electrode in drug analysis
    Guo, Yong-Li
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 1999, 20 (5 Suppl):
  • [37] Novel PVC-based membrane sensors selective for vanadyl ions
    Jain, AK
    Gupta, VK
    Singh, LP
    Khurana, U
    TALANTA, 1998, 46 (06) : 1453 - 1460
  • [38] Fabrication of Mercury Ion Selective Electrode Based on a Porphyrin Derivative with Plasticized PVC Membrane
    Long, Shu
    Li, Ji-Shan
    Ding, Shan-Shan
    Luo, Yong-Feng
    Zhao, Rong-Na
    Cao, Zhong
    FUNDAMENTAL OF CHEMICAL ENGINEERING, PTS 1-3, 2011, 233-235 : 1994 - 1997
  • [39] Study of PVC-based Skin Phantom with graphite particles in Terahertz Frequency Range
    Zhang, T.
    Khodzitsky, M. K.
    Demchenko, P. S.
    Bykov, A., V
    Popov, A. P.
    Meglinski, I., V
    3RD INTERNATIONAL CONFERENCE TERAHERTZ AND MICROWAVE RADIATION: GENERATION, DETECTION AND APPLICATIONS (TERA-2018), 2018, 195
  • [40] Potentiometric Study of Coated Graphite Electrode and Polymeric Membrane Electrode for the Determination of Sm3+Ion
    Upadhyay, Anjali
    Singh, A. K.
    Jain, A. K.
    Gupta, Vinod Kumar
    Bandi, Koteswara Rao
    ELECTROANALYSIS, 2012, 24 (07) : 1630 - 1638