Bone bonding, displacement, and absorption in cases of double-door laminoplasty with unidirectional porous hydroxyapatite spacers

被引:11
作者
Noguchi, Hiroshi [1 ]
Koda, Masao [1 ]
Funayama, Toru [1 ]
Kumagai, Hiroshi [1 ]
Abe, Tetsuya [1 ]
Nagashima, Katsuya [1 ]
Miura, Kousei [1 ]
Mataki, Kentaro [1 ]
Fujii, Kengo [1 ]
Yamazaki, Masashi [1 ]
机构
[1] Univ Tsukuba, Dept Orthopaed Surg, Fac Med, 1-1-1 Tennodai, Tsukuba, Ibaraki 3058575, Japan
基金
日本学术振兴会;
关键词
Double-door laminoplasty; Hydroxyapatite; Spacer; Complication; Cervical spine; Bone bonding; CERVICAL LAMINOPLASTY; MYELOPATHY;
D O I
10.1016/j.jocn.2019.01.012
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We used a newly developed, high-porosity unidirectional porous hydroxyapatite spacer (Regenos spacer, not approved by the FDA). To assess the short-term bone bonding capacity of Regenos spacer used in a double-door laminoplasty, including displacement, deformation, and absorption after implantation. Fifty patients underwent a double-door laminoplasty using Regenos spacers, with computed tomography (CT) images obtained at 2-4 weeks and 6-12 months, post-surgery, in 30 patients. Bone bonding rate, amount of displacement, and the incidence of deformation and absorption were evaluated from the early and late postoperative CT images. Bone bonding rate for Regenos spacers, using our modified classification, was 48.9% at 6 months, post-surgery, and 67.0% at 12 months. The change in anterior-posterior diameter of the spinal canal (Delta H) was significantly greater for Regenos spacers than for autologous bone spacers (p < 0.05). There was no difference in the change in angle between the vertebral arch and the posterior wall of the vertebral body (Delta R) between the Regenos and autologous bone spacers. Deformation was identified in 21.3% (10/47). Though, no evidence of breakage along their long axis was identified among these 10 cases on axial Cr images with passable clinical results. Regenos spacers lowered the risk of early dislocation after implantation and facilitated bone bonding due to infiltration of surrounding tissue. However, the deformation and absorption was observed at high rates because of their insufficient mechanical strength, we need to require a longer term follow-up to more clearly evaluate their adverse impact in clinically. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:46 / 52
页数:7
相关论文
共 21 条
[1]   Posterior movement and enlargement of the spinal cord after cervical laminoplasty [J].
Aita, I ;
Hayashi, K ;
Wadano, Y ;
Yabuki, T .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (01) :33-37
[2]  
Ando M, 2005, CENT JPN J ORTHOP TR, V48, P457
[3]  
Enyo Y, 2010, CENTRAL JAPAN J ORTH, V53, P51
[4]   Histological Analysis of Bone Bonding and Ingrowth into Connected Porous Hydroxyapatite Spacers in Spinal Surgery [J].
Funayama, Toru ;
Noguchi, Hiroshi ;
Tsukanishi, Toshinori ;
Sakane, Masataka .
BIOCERAMICS 24, 2013, 529-530 :309-+
[5]  
Hirabayashi S, 1999, J Orthop Sci, V4, P264
[6]  
Ichikawa S, 1994, J JAPAN SPINE RES SO, V5, P215
[7]   Cervical laminoplasty: evaluation of bone bonding of a high porosity hydroxyapatite spacer [J].
Iguchi, T ;
Kanemura, A ;
Kurihara, A ;
Kasahara, K ;
Yoshiya, S ;
Doita, M ;
Nishida, K .
JOURNAL OF NEUROSURGERY, 2003, 98 (02) :137-142
[8]  
Ito J, 1990, SPINE SPINAL CORD, V3, P556
[9]   Bone Regeneration and Remodeling within a Unidirectional Porous Hydroxyapatite Bone Substitute at a Cortical Bone Defect Site: Histological Analysis at One and Two Years after Implantation [J].
Iwasashi, Masashi ;
Funayama, Toru ;
Watanabe, Arata ;
Noguchi, Hiroshi ;
Tsukanishi, Toshinori ;
Suetsugu, Yasushi ;
Makihara, Takeshi ;
Ochiai, Naoyuki ;
Yamazaki, Masashi ;
Sakane, Masataka .
MATERIALS, 2015, 8 (08) :4884-4894
[10]   Postoperative displacement of hydroxyapatite spacers implanted during double-door laminoplasty Clinical article [J].
Kaito, Takashi ;
Hosono, Noboru ;
Makino, Takahiro ;
Kaneko, Noriyoshi ;
Namekata, Masato ;
Fuji, Takeshi .
JOURNAL OF NEUROSURGERY-SPINE, 2009, 10 (06) :551-556