A validated method to quantify folic acid in wheat flour samples using liquid chromatography - Tandem mass spectrometry

被引:14
|
作者
Martins-Junior, Helio A. [1 ]
Wang, Alexandre Y. [1 ]
Alabourda, Janete [2 ]
Pires, Maria A. E. [3 ]
Vega, Oscar B. [3 ]
Lebre, Daniel T. [4 ]
机构
[1] Appl Biosyst Brazil Ltda, BR-04311000 Sao Paulo, Brazil
[2] Inst Adolfo Lutz Registro, Dept Bromatol & Quim, BR-01246902 Sao Paulo, Brazil
[3] IPEN CNEN SP, CQMA, BR-05508000 Sao Paulo, Brazil
[4] Appl Biosyst MDS Sciex, Concord, ON L4K 4V8, Canada
关键词
folic acid; validation; liquid chromatography; tandem mass spectrometry;
D O I
10.1590/S0103-50532008000500024
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In order to monitor the fortification level of folic acid (vitamin B9) in wheat flour samples, we developed and validated a simple and fast analytical method using the liquid chromatography with tandem triple quadrupole mass spectrometry (LC-MS/MS) technique. The compound was ionized by an electrospray source in positive mode. The tandem MS/MS instrument was set in MRM (Multiple Reaction Monitoring) mode to detect two m/z transitions used for quantitation and confirmation purposes. A total of 83 samples were prepared to validate the method according to the regulatory guidelines from the Commission Decision 2002/657/EC for food residues analysis. The method performance was evaluated in regards to linearity, accuracy, precision, sensitivity, and uncertainty. The statistical analysis of the results showed a correlation coefficient (r(2)) of 1.000 within the concentration range of 1.0 to 50 mu g L-1. The method reproducibility of 5.6% was obtained by calculating the standard deviation sum of the intra-day and inter-day analysis at a fortification level limit of 1.50 mu g g(-1) of folic acid. In addition, ten blank spiked samples at the fortification level limit were extracted and analyzed with an accuracy of 85% and a precision of 3 % (coefficient of variation). The method sensitivity was expressed in decision limit (CC alpha) of 0.06 mu g g(-1) and detection capability (CC beta) of 0.11 mu g g(-1). The total measurement uncertainty method calculated was +/- 0. 11 mu g g(-1). Different brands of Brazilian wheat flour were evaluated and reported.
引用
收藏
页码:971 / 977
页数:7
相关论文
共 50 条
  • [41] Liquid chromatography-tandem mass spectrometry method for the determination of vanillylmandelic acid in urine
    Magera, MJ
    Thompson, AL
    Matern, D
    Rinaldo, P
    CLINICAL CHEMISTRY, 2003, 49 (05) : 825 - 826
  • [42] Analysis of carbohydrate heterogeneity in a glycoprotein using liquid chromatography mass spectrometry and liquid chromatography with tandem mass spectrometry
    Kawasaki, N
    Ohta, M
    Hyuga, S
    Hashimoto, O
    Hayakawa, T
    ANALYTICAL BIOCHEMISTRY, 1999, 269 (02) : 297 - 303
  • [43] Liquid chromatography–tandem mass spectrometry
    Mira Petrovic
    Damià Barceló
    Analytical and Bioanalytical Chemistry, 2013, 405 : 5857 - 5858
  • [44] Development of a validated ultra-high-performance liquid chromatography tandem mass spectrometry method for determination of acid diterpenes in Copaifera oleoresins
    Mangabeira da Silva, Jonas Joaquim
    Crevelin, Eduardo Jose
    Carneiro, Luiza Junqueira
    Rogez, Herve
    Sola Veneziani, Rodrigo Cassio
    Ambrosio, Sergio Ricardo
    Beraldo Moraes, Luiz Alberto
    Bastos, Jairo Kenupp
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1515 : 81 - 90
  • [45] A liquid chromatography tandem mass spectrometry method for plasma glucagon
    Nguyen, Van Long
    Tuckwell, Phillip
    Ireland, Andrea
    Fitzpatrick, Michael
    ANALYTICAL BIOCHEMISTRY, 2023, 675
  • [46] A novel method to quantify chitosan in aqueous solutions by ultrahigh-performance liquid chromatography–tandem mass spectrometry
    Xue, Ting
    Zhou, Lei
    Wang, Fanjun
    Tian, Zhuang
    Li, Nanxi
    Ye, Tong
    Hao, Ruolin
    Yang, Lei
    Gu, Ruolan
    Gan, Hui
    Wu, Zhuona
    Zhu, Xiaoxia
    Liu, Shuchen
    Sun, Yunbo
    Dou, Guifang
    Meng, Zhiyun
    Carbohydrate Polymers, 2024, 329
  • [47] Thyronamines in Humans: Development of a Validated Isotope Dilution Liquid Chromatography/Tandem Mass Spectrometry Method for Their Measurement.
    Soldin, O. P.
    Gu, J.
    Soldin, S. J.
    ENDOCRINE REVIEWS, 2010, 31 (03)
  • [48] Quantitation of plasma angiotensin II in healthy Chinese subjects by a validated liquid chromatography tandem mass spectrometry method
    Lo, Clara Wai-Shan
    Tsui, Teresa Kam-Chi
    Ma, Ronald Ching-Wan
    Chan, Michael Ho-Ming
    Ho, Chung-Shun
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (05)
  • [49] A validated liquid chromatography-tandem mass spectrometry method for the quantitative determination of 4β-hydroxycholesterol in human plasma
    van de Merbel, Nico C.
    Bronsema, Kees J.
    van Hout, Mischa W. J.
    Nilsson, Ralf
    Sillen, Henrik
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (05) : 1089 - 1095
  • [50] Validated Ultra-Performance Liquid Chromatography Tandem Mass Spectrometry Method for the Determination of Pramipexole in Human Plasma
    Yadav, Manish
    Rao, Rajasekhar
    Kurani, Hemal
    Rathod, Jaysukh
    Patel, Rakesh
    Singhal, Puran
    Shrivastav, Pranav S.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2010, 48 (10) : 811 - 818