A validated method to quantify folic acid in wheat flour samples using liquid chromatography - Tandem mass spectrometry

被引:14
|
作者
Martins-Junior, Helio A. [1 ]
Wang, Alexandre Y. [1 ]
Alabourda, Janete [2 ]
Pires, Maria A. E. [3 ]
Vega, Oscar B. [3 ]
Lebre, Daniel T. [4 ]
机构
[1] Appl Biosyst Brazil Ltda, BR-04311000 Sao Paulo, Brazil
[2] Inst Adolfo Lutz Registro, Dept Bromatol & Quim, BR-01246902 Sao Paulo, Brazil
[3] IPEN CNEN SP, CQMA, BR-05508000 Sao Paulo, Brazil
[4] Appl Biosyst MDS Sciex, Concord, ON L4K 4V8, Canada
关键词
folic acid; validation; liquid chromatography; tandem mass spectrometry;
D O I
10.1590/S0103-50532008000500024
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In order to monitor the fortification level of folic acid (vitamin B9) in wheat flour samples, we developed and validated a simple and fast analytical method using the liquid chromatography with tandem triple quadrupole mass spectrometry (LC-MS/MS) technique. The compound was ionized by an electrospray source in positive mode. The tandem MS/MS instrument was set in MRM (Multiple Reaction Monitoring) mode to detect two m/z transitions used for quantitation and confirmation purposes. A total of 83 samples were prepared to validate the method according to the regulatory guidelines from the Commission Decision 2002/657/EC for food residues analysis. The method performance was evaluated in regards to linearity, accuracy, precision, sensitivity, and uncertainty. The statistical analysis of the results showed a correlation coefficient (r(2)) of 1.000 within the concentration range of 1.0 to 50 mu g L-1. The method reproducibility of 5.6% was obtained by calculating the standard deviation sum of the intra-day and inter-day analysis at a fortification level limit of 1.50 mu g g(-1) of folic acid. In addition, ten blank spiked samples at the fortification level limit were extracted and analyzed with an accuracy of 85% and a precision of 3 % (coefficient of variation). The method sensitivity was expressed in decision limit (CC alpha) of 0.06 mu g g(-1) and detection capability (CC beta) of 0.11 mu g g(-1). The total measurement uncertainty method calculated was +/- 0. 11 mu g g(-1). Different brands of Brazilian wheat flour were evaluated and reported.
引用
收藏
页码:971 / 977
页数:7
相关论文
共 50 条
  • [21] Development of an analytical method to quantify pharmaceuticals in fish tissues by liquid chromatography-tandem mass spectrometry detection and application to environmental samples
    Boulard, Lise
    Parrhysius, Pia
    Jacobs, Bjoern
    Dierkes, Georg
    Wick, Arne
    Buchmeier, Georgia
    Koschorreck, Jan
    Ternes, Thomas A.
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1633 (1633)
  • [22] Multiresidue analysis of 47 pesticides in cooked wheat flour and polished rice by liquid chromatography with tandem mass spectrometry
    Lee, Sung Jung
    Park, Hyeong Jin
    Kim, Wooseong
    Jin, Jong Sung
    Abd El-Aty, A. M.
    Shim, Jae-Han
    Shin, Sung Chul
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (04) : 434 - 442
  • [23] Development and validation of liquid chromatography tandem mass spectrometry method to quantify androgens in recurrent prostate cancer
    Titus, M
    Lih, F
    Tomer, K
    Mohler, JL
    JOURNAL OF UROLOGY, 2006, 175 (04): : 136 - 137
  • [24] Determination of amines as pentafluoropropionic acid anhydride derivatives in biological samples using liquid chromatography and tandem mass spectrometry
    Marand, Å
    Karlsson, D
    Dalene, M
    Skarping, G
    ANALYST, 2004, 129 (06) : 522 - 528
  • [25] Determination of chloramphenicol in meat samples using liquid chromatography-tandem mass spectrometry
    Akter Mou, Salma
    Islam, Rafiza
    Shoeb, Mohammad
    Nahar, Nilufar
    FOOD SCIENCE & NUTRITION, 2021, 9 (10): : 5670 - 5675
  • [26] The analysis of dried blood spot samples using liquid chromatography tandem mass spectrometry
    Keevil, Brian G.
    CLINICAL BIOCHEMISTRY, 2011, 44 (01) : 110 - 118
  • [27] VALIDATED LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY METHOD FOR DETERMINATION AND PHARMACOKINETIC STUDY OF METOLAZONE IN RAT PLASMA
    Dubey, Ramkumar
    Das, Soumyajit
    Kant, Kamal
    Ghosh, Manik
    18TH INTERNATIONAL ELECTRONIC CONFERENCE ON SYNTHETIC ORGANIC CHEMISTRY, 2014,
  • [28] Liquid chromatography-tandem mass spectrometry validated method for the estimation of indapamide in human whole blood
    Jain, DS
    Subbaiah, G
    Sanyal, M
    Pande, UC
    Shrivastav, P
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 834 (1-2): : 149 - 154
  • [29] Determination of iodoacetic acid using liquid chromatography/electrospray tandem mass spectrometry
    Lau, Benjamin P. -Y.
    Becalski, Adam
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (12) : 1787 - 1791
  • [30] Analysis of mycophenolic acid in saliva using liquid chromatography tandem mass spectrometry
    Mendonza, Anisha E.
    Gohh, Reginald Y.
    Akhlaghi, Fatemeh
    THERAPEUTIC DRUG MONITORING, 2006, 28 (03) : 402 - 406